Files
werewulf/docs/24-bare-metal.md
ilkerandClaude Opus 5.5 d07f443d0b
ci / derle (push) Successful in 49s
baremetal: run on SONiC, and the four bugs it found
The sonic driver, tested only against a fake until now, built a cluster
on SONiC 202505 (VS), cleaned two machines at once in its cleaning VLAN,
and released them. Fixed on the way:

- port changes raced: parallel processes both created a cluster's VLAN;
  the driver now locks on the switch around every change
- a cleaning killed between its two switch changes left a dirty machine
  in no VLAN, which looks free; a cleaning now records its start first,
  a machine is free only if its last cleaning finished and passed, and
  one cleaning per machine runs at a time under a lock
- the portal's startup sweep marked a selftest's destroy failed, which
  killed it; builds and destroys hold a lock the sweep respects
- setup wrote the trunk's configuration without applying it

Also selftest -boot-timeout, sonic.sh prepare, and the portal showing an
interrupted cleaning, with Retry.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-11-24 17:33:34 +01:00

448 lines
24 KiB
Markdown

# 24. Bare metal — clusters on physical machines
Section 20 builds a tenant cluster out of virtual machines on a hypervisor.
This section is the backend where the compute nodes are not guests but
servers: a rack of machines with BMCs, cabled to a fabric switch, given to
one cluster at a time, and wiped before the next.
**Status: built, and run end to end on a simulated rack.** Placement,
discovery, power, network boot, per-cluster VLANs, cleaning, the portal's
view of the machines, and the switch drivers have been run on the
simulation described in 24.10, which is built from the same software a
real rack runs (Redfish, IPMI, a VLAN-filtering bridge, SONiC 202505, real
NVMe and ATA command sets as QEMU emulates them). None of it has yet run on physical
hardware; 24.11 is the list of what that will be the first test of.
---
## 24.1 What a bare-metal site is
```
control plane (hpcod)
placement · portal · Terraform runner
│ SSH (pinned) │ Redfish / IPMI
┌─────────────────┴───────┐ ┌───┴──────────────────────────┐
│ head host (KVM) │ │ BMCs (out-of-band network) │
│ heads: one VM/cluster │ └───┬───────────┬──────────┬───┘
│ bridge, VLAN-aware │ │ │ │
│ hpcod-switch, -clean │ ┌──┴──┐ ┌──┴──┐ ┌──┴──┐
└──────────┬──────────────┘ │ m01 │ │ m02 │ … │ mNN │
│ trunk (all cluster VLANs, cleaning VLAN) machines
┌─────┴──────────────────────────┴───────────┴──────────┴──┐
│ fabric switch: one access port per machine, in its │
│ cluster's VLAN or in none │
└──────────────────────────────────────────────────────────┘
```
- **The head** of each cluster is still a VM, on one libvirt/KVM host
beside the rack: built by the libvirt module (§20), from the same head
image. Its fabric NIC is a port on that host's VLAN-aware bridge.
- **Compute nodes are machines.** A node gets a whole machine, whatever it
asked for; nothing else is placed on that machine until the cluster is
released. Machines boot diskless from their head (Warewulf, PXE), as
guests do.
- **Isolation is the switch's.** Every cluster has a VLAN,
`BM_VLAN_BASE + cluster_id`. Its head's port and its machines' ports are
access ports in it; a port in no cluster is in no VLAN at all, so a
machine nobody holds can reach nothing.
- **Power is the BMC's**, through Redfish or IPMI: on with a one-time
network boot, off.
The code: `internal/provider/baremetal` (discovery, ports, power, cleaning),
`internal/redfish`, `terraform/envs/baremetal`, `internal/setup/baremetal_backend.go`,
and the scripts the head host runs, `deploy/switch/` and `deploy/clean/`.
## 24.2 A cluster's life
1. **Placement.** The head goes to the head host (`HeadOnly`), each compute
node to a free machine big enough for it (`Machine`). A machine is free
when the switch has its port in no VLAN, it is powered off, and no live
cluster holds it in the database.
2. **Recording.** The cluster is recorded with its machines
(`cluster_machine`, one live holder per machine, enforced by a unique
index). Two requests planned in the same second cannot both get one.
3. **Build** (`tofu apply`, `started=false`): the head VM, its port into the
cluster's VLAN on the head host, each machine's port into it on the
fabric switch. The machines stay off.
4. **Start** (`started=true`, once the head's portal answers): each machine
is set to network boot once and powered on. It PXE boots from its head,
which knows it by MAC, and joins Slurm.
5. **Release** (`tofu destroy`): machines powered off; each is then
*cleaned* (24.6) — not freed — and the head VM and its port go. The
database releases the machines only when Terraform has finished, which
it has not until every cleaning passed.
Every switch and BMC change is read back before the step returns, because
Terraform takes exit 0 as done and never looks again.
## 24.3 Isolation, in detail
| Port | Where | VLAN |
|---|---|---|
| a head's fabric NIC | head host bridge, by MAC | its cluster's, untagged |
| a machine's NIC | fabric switch, by port | its cluster's, untagged; none when free |
| head host ↔ switch | both ends | trunk: every cluster VLAN, and the cleaning VLAN, tagged |
| a machine being cleaned | fabric switch | the cleaning VLAN, `BM_VLAN_BASE + 255` |
- The head host's bridge filters VLANs and puts new ports in none
(`DefaultPVID=none`). Setup refuses a bridge that does otherwise: with a
default VLAN, every unassigned port shares one segment.
- A guest's port on the head host is a tap made anew at each start. A
libvirt hook, which setup installs with `hpcod-switch`, puts it back in
its VLAN on every start; without it a rebooted head would be cut off.
- A machine's port is never moved from one cluster's VLAN to another's.
The only move allowed is into the cleaning VLAN, on release.
- Nothing is routed out of the cleaning VLAN on the head host.
Tested on the simulation with two clusters up at once: a machine's traffic
reached its own head and not the other (tcpdump on both heads' ports while
it network booted), and a machine powered on behind hpcod's back, in no
VLAN, reached neither. `hpcod baremetal power` refused to boot it, and
discovery reported it as not free.
## 24.4 Configuration
### site.env (setup)
`SITE_KIND=baremetal`, everything a libvirt site has for the head host
(`LIBVIRT_*`, `MGMT_*`), and:
| Key | Default | |
|---|---|---|
| `BM_FABRIC_BRIDGE` | `bmfab` | the head host's VLAN-aware bridge onto the fabric |
| `BM_UPLINK` | empty | its port to the switch, carrying every VLAN tagged |
| `BM_VLAN_BASE` | `1000` | cluster N is on base+N; base+255 is the cleaning VLAN |
| `BM_CLEAN_ADDR` | `172.31.255.1/24` | the head host's address in the cleaning VLAN |
| `BM_CLEAN_MODE` | `purge` | `full` also overwrites disks that were purged |
| `BM_MACHINES` | `/etc/hpcod/machines.yaml` | the machines file |
| `BM_ENROLL` | empty | Redfish services to write the machines file from, once |
| `BMC_USER`, `BMC_INSECURE`, `BMC_CA` | `admin`, `false`, empty | the site's BMC login and trust |
The BMC password is not in `site.env`, which is world-readable: it is given
to setup as `BMC_PASSWORD` in its environment and kept in `/etc/hpcod/env`.
IPMI passwords are at most 20 bytes, that protocol's limit; a longer one is
refused before any IPMI call.
### machines.yaml
```yaml
switches: # optional; without it, the site has one switch
- {name: tor1, driver: sonic, host: 192.0.2.40, uplink: Ethernet48}
- {name: tor2, driver: exec, command: /usr/local/bin/netauto}
machines:
- name: node01
bmc: https://192.0.2.50/redfish/v1/Systems/1 # or ipmi://host[:port]
mac: "b8:59:9f:00:00:01" # the NIC cabled to the fabric
switch: tor1
switch_port: Ethernet0
bmc_user: root # optional: this machine's own login
bmc_password: file:/etc/hpcod/bmc/node01 # env:NAME or file:/path only
- name: old01
bmc: ipmi://192.0.2.60
mac: "00:25:90:00:00:01"
cores: 16 # required for IPMI, which reports no size
memory_gb: 64
switch: tor2
switch_port: "Gi1/0/12"
```
The file is checked as a whole and every problem reported at once: names,
MACs (no multicast, no duplicates), BMC URLs, one machine per switch port,
the uplink never a machine's port, and passwords only as references — a
password written into the file is an error, not a password.
The MAC is configured, not discovered: a server has several NICs, and which
one is on the fabric is a fact about the cabling. Discovery and setup check
that the BMC reports it, where the BMC reports NICs at all.
### From NetBox
Where the data centre keeps its servers in NetBox, the file is written from
there instead of by hand: `hpcod netbox` reads the site's devices, their
NICs and MACs, which switch port each NIC is cabled to, and their BMC
addresses. A wrong MAC or port in a hand-written file puts a machine into
another cluster's VLAN; one written from the cabling record does not drift
from it.
```sh
export NETBOX_TOKEN=... # read-only is enough; never written to
hpcod netbox -url https://netbox.example -site dc1 -role hpc-compute # shows it
hpcod netbox -url https://netbox.example -site dc1 -role hpc-compute -write
systemctl restart hpcod-portal # the service reads the file when it starts
```
| Machine field | From NetBox |
|---|---|
| name | the device's name, lower-cased |
| mac | the fabric interface's primary MAC (NetBox 4.2+), or its `mac_address` before that |
| switch, switch_port | the device and interface at the other end of that interface's cable |
| bmc | the custom field `hpcod_bmc` (a full URL) where set; else the device's out-of-band IP as `https://IP/redfish/v1/Systems/1` (`-redfish-system` changes the path, `-bmc ipmi` makes it `ipmi://IP`) |
| cores, memory_gb | custom fields `hpcod_cores`, `hpcod_memory_gb`, where set |
| bmc_user, bmc_password | custom fields `hpcod_bmc_user`, `hpcod_bmc_password` (a reference, as in the file) |
Which devices: active ones at the site with the role (`-role`) and/or tag
(`-tag`) given — one of them is required, or every device at the site,
switches included, would be a machine.
Which NIC: NetBox does not know which network is the cluster fabric, and
the import does not guess. The fabric switches are the ones the file's
`switches:` section names — by their NetBox name, lower-cased — or, for a
file without one, the single switch named with `-switch`. A machine's
fabric NIC is its one interface cabled to a fabric switch. None, or more
than one, is an error.
What NetBox does not know, the file keeps: the `switches:` section (drivers,
hosts, commands), and a machine's size or login where NetBox has no custom
field set for it. A machine in the file that NetBox no longer lists is kept
and reported; `-prune` drops it — first make sure no cluster holds it.
Every device that cannot be made a machine is listed, and then nothing is
written: a machine quietly left at what the file said before is the drift
this is for. The file is written only if it checks as `ReadMachines` checks
it; the old one is kept as `machines.yaml.prev`, owner and mode are kept,
and the result is read back and compared before the command succeeds.
Tested against a real NetBox 4.7.5 (netbox-docker) holding the simulated
rack, with a read-only v2 token: the file it wrote was the hand-written
one, field for field, with a second NIC on a management switch and a
non-machine device on the fabric switch both left out; a drifted file
(wrong MAC and port, a machine missing, a stale one) was put right with
`-write -prune`; a BMC from the out-of-band IP; and a machine given a
second fabric NIC was refused, with nothing written. NetBox before 4.2
(MAC on the interface) is covered by unit tests only.
## 24.5 Switch drivers
| Driver | How | Status |
|---|---|---|
| `linux-bridge` | `hpcod-switch` on a host, over SSH; ports by MAC | tested end to end |
| `exec` | a program of the site's: `CMD assign\|clear\|list SWITCH [PORT [VLAN]]` | tested end to end |
| `http` | the same over REST, bearer token | unit-tested |
| `sonic` | SONiC over SSH: `config` to change, CONFIG_DB to read | tested end to end on SONiC VS 202505 |
The `sonic` driver takes a lock on the switch (a file in its login's home)
around every change. A cluster's ports are made in parallel, each by its own
process, and a VLAN's first and last members are read-then-write: the first
run on a real SONiC had two machines both find the new VLAN missing and both
add it, and the second failed. SONiC expects the ports it is given to be
plain L2 ports - a routed port (one with an IP address) cannot be a VLAN
member, and is the network team's to change, not hpcod's.
`exec` and `http` are for the common case where the network team does not
let applications log in to switches but does have automation — an Ansible
job, a NetBox script — that hpcod can call. The contract:
```
assign SWITCH PORT VLAN PORT an access port in VLAN, saved
clear SWITCH PORT PORT in no VLAN
list SWITCH "PORT VLAN" for every access port in a VLAN
GET {url}/switches/{switch}/ports {"ports": {"Ethernet0": 1001}}
PUT {url}/switches/{switch}/ports/{port} {"vlan": 1001}
DELETE {url}/switches/{switch}/ports/{port}
```
A change must be made, not queued, before the call returns: hpcod reads
`list` back after every change and stops if it disagrees (a program that
claims success without changing anything is caught). Arguments are passed
as an argument list, never through a shell. `deploy/baremetal-sim/netauto-example`
is a working example.
Uplinks — between switches, and to the head host — are the network team's,
configured once as trunks carrying `BM_VLAN_BASE` to `BM_VLAN_BASE + 255`.
hpcod changes access ports only. Setup pins the host keys of SSH-driven
switches on first contact and refuses a changed one after.
## 24.6 Cleaning
A released machine is wiped before anyone else gets it. The nodes boot
diskless, but a real server has local disks, and a tenant with root on a
node can write to them.
**How.** The machine is powered off, its port moved into the cleaning
VLAN, and it network boots, once, a wipe image that `hpcod-clean` on the
head host builds from that host's own kernel and busybox and serves from
dnsmasq and busybox httpd — in that VLAN only. A machine gets the image only
while it is armed: iPXE asks for a script named after its MAC, which exists
only between arm and disarm, and every cleaning has a random one-time token.
**What the image does to each non-removable disk** (NIST SP 800-88):
| Device | Purge, in order of preference |
|---|---|
| NVMe | sanitize (crypto, then block erase) — whole controller, every namespace; else format with secure erase |
| ATA | host protected area removed; sanitize (crypto, block); else enhanced secure erase if not frozen |
| SCSI / SAS | sanitize (crypto, block) |
| anything else, or any of the above that refuses | **clear**: overwritten whole with zeros, read back whole |
A purge reaches what an overwrite cannot: spare flash, remapped sectors,
hidden namespaces. A disk that can only be cleared is reported as such;
the site decided (this is a policy choice) that a cleared machine may be
given out again.
**How it is checked.** Before the wipe, markers carrying the token are
written at 64 random places across each disk; after it, none may be
readable. That works for every method — after a crypto erase a disk reads
as noise, not zeros. An overwrite is also read back as zeros end to end.
Discard (TRIM) is not a method: a drive may keep, and return, what it was
asked to discard.
**The decision is the control plane's.** The image reports each disk's
method, level and check, with the token, and powers off. hpcod frees the
port only on a complete report of *that* cleaning with every disk
verified and a level for each. Anything else — no report by the deadline,
a disk that failed, another cleaning's token, a cut-off report — leaves the
machine powered off and in the cleaning VLAN, which discovery reads as
held. The cluster's release fails until someone looks.
**Records.** Every cleaning, passed or failed, is in
`/var/lib/hpcod/cleaning/<site>/<machine>.jsonl`: when, at whose request,
each disk's method, level, sample count and result. A cleaning writes a line
when it starts, before it touches the machine, and another when it ends;
the end is written before the port is freed, and a cleaning whose record
cannot be written fails.
**A machine is free only if it is known to be clean.** On the switch, a
free machine is a port in no VLAN — and so is a machine whose cleaning was
killed between taking its port out of the cluster's VLAN and putting it in
the cleaning one (two switch changes). So a port in no VLAN counts as free
only when the machine's last cleaning finished and passed; a start with no
end, or a failure, holds it. That happened on the simulation: a cleaning's
Terraform was interrupted, and until this rule the machine showed as free
with the tenant's data on its disks.
One cleaning of a machine runs at a time: each holds a lock,
`<machine>.lock` beside its record, for as long as it runs. That is also
how a running cleaning is told from one whose process died.
**Retrying.** `hpcod baremetal clean -site S -machine M`, or the portal's
Retry button (24.7). A retry takes a machine whose last cleaning failed or
never finished, with its port in the cleaning VLAN or in none — never one in
a cluster's VLAN, and never one being cleaned.
**Tested on the simulation**, with tenant data written into each disk and
checked from the host by `qemu-io` exit codes: an NVMe disk purged by
format with secure erase, a SATA and a virtio disk cleared by overwrite, all
three wiped and the machine freed in 58 s; with the cleaning service
stopped, the machine left off and held; a retry freed it. Not yet tested:
NVMe sanitize, ATA sanitize and secure erase, SCSI sanitize — QEMU does not
implement them — and any real drive's firmware.
What cleaning does **not** cover is in 24.9.
## 24.7 The portal
The sites page lists a bare-metal site's machines: state (free; in use, and
by which VLAN; cleaning; cleaning failed, and why; unreachable, and why),
size, and the last cleaning with each disk's method and level. An
administrator sees a **Retry cleaning** button on a machine whose last
cleaning failed, and nowhere else. The portal refuses a retry for a machine
whose last cleaning passed (a release may be cleaning it now) or one already
being retried; the provider refuses, against the switch, one that is not
waiting in the cleaning VLAN. Retries are attributed to whoever pressed.
Placing and releasing machines are a cluster's business; the portal has no
other control over them.
## 24.8 Operating it
| Command | |
|---|---|
| `hpcod verify` | the head host, switch driver, cleaning service, machines file, every machine through its BMC, and how many are free |
| `hpcod discover -json` | every machine with `allocated_to` and `problem` |
| `hpcod baremetal port -site S -machine M -vlan N \| -clear` | a port by hand |
| `hpcod baremetal power -site S -machine M -on -vlan N \| -off` | power by hand; refuses to boot a machine whose port is not in that VLAN |
| `hpcod baremetal clean -site S -machine M` | wipe and free one machine |
| `hpcod-switch list` (head host) | ports the linux-bridge driver has assigned |
| `systemctl status hpcod-clean` (head host) | the cleaning service |
**Reading a machine's state.**
| Shown as | Meaning | What to do |
|---|---|---|
| free | port in no VLAN, powered off | — |
| in use, VLAN N (cluster k) | a live cluster has it | — |
| in use, powered on, in no cluster's VLAN | someone switched it on outside hpcod | find out who; hpcod will not offer it |
| cleaning | a release or a retry is wiping it | wait |
| cleaning failed | its last cleaning did not pass; held | read the record's error, fix, Retry |
| cleaning interrupted | its last cleaning started and never finished — the process was killed; held, its disks not known to be clean | Retry |
| unreachable: BMC … | its BMC refused or did not answer | check the BMC, its login, the OOB network |
| unreachable: the BMC lists NICs …, not … | `mac` in the machines file is not this machine's NIC | fix the machines file |
| unreachable: switch … | the switch could not be read; nothing on it is offered | check the switch or the delegated program |
## 24.9 Security limits
- **Cleaning covers disks only.** Firmware, BIOS settings, EFI variables,
the BMC's own accounts and storage (vFlash, SD modules) are not checked,
and a tenant with root on a node can reach the BMC from inside it (IPMI
over KCS, the Redfish host interface). Turn those interfaces off on the
machines, or do not give tenants root.
- **A purge is as good as the drive's firmware.** Buy drives that support
sanitize (or self-encrypting ones) where purge is required everywhere; a
disk that cannot be purged is only cleared.
- **An overwrite takes hours on a large disk**, and the cluster's release
waits for it.
- **The trunk to the head host** carries every cluster's VLAN; the head
host is trusted, as the hypervisor is on the other backends.
## 24.10 The simulation
`deploy/baremetal-sim/setup.sh`, run as root on a libvirt host, makes a rack
out of that host:
- **machines** `bm01…`: guests with the network first in the boot order and
a local disk each, their MACs fixed as a real NIC's are;
- **BMCs**: sushy-emulator, one Redfish service fronting all of them, and
virtualbmc giving some (`IPMI_MACHINES`) an IPMI BMC as well;
- **the switch**: a VLAN-filtering bridge with no default VLAN.
`deploy/baremetal-sim/sonic.sh` re-cables the same rack behind a SONiC VM
(one two-ended bridge per machine as its cable, a trunk to the head host),
and `sonic.sh prepare ADDRESS` then makes it the switch a network team would
hand over: the VS image boots as a router, every port with an address, so
those go, and hpcod's key is given its admin login. (The addresses were first
removed by hand, with the same commands; `prepare` has since run only on the
switch already prepared.) Its data plane is
software (saivs) and slow - about 0.45 MB/s per machine - so a node's
network boot through it takes over 15 minutes, and selftest needs
`-boot-timeout 30m`. `deploy/baremetal-sim/netauto-example` is an `exec`
driver for the simulation.
What has been run on it, on one nested-KVM host:
| Run | Result |
|---|---|
| `hpcod selftest -compute 2` (Redfish machines) | built, Slurm idle on both, `srun -N 2`, released |
| `hpcod selftest -compute 3` (two Redfish, one IPMI) | the same with three; the IPMI machine never touched Redfish |
| two clusters at once | each machine's traffic reached only its own head; an unassigned machine reached neither |
| selftest through the `exec` driver, one machine with its own BMC login | passed; a wrong password failed that machine alone |
| cleaning: NVMe, SATA, virtio disks with tenant data | NVMe purged, the others cleared, data gone, freed in 58 s |
| cleaning with the service stopped; then a retry | held and powered off; the retry freed it |
| portal: failed cleaning, Retry pressed | shown with one button; cleaned and freed in a minute; second press 409 |
| `hpcod selftest -compute 2 -boot-timeout 30m` behind SONiC 202505 | built through the switch and the trunk, `srun -N 2`, released, both machines cleaned in parallel; 17 min, most of it the image at the VS's software speed |
| two machines' ports changed at once on SONiC | first run: the second failed adding the VLAN the first had just added; with the switch-side lock, both assigned and both cleared |
| a cleaning killed with `kill -9` while moving the port, port then in no VLAN | held as "never finished", shown as cleaning interrupted with Retry; Retry purged NVMe, cleared SATA and virtio, freed it |
| the portal restarted during a selftest's destroy | left it alone (its lock held); the destroy finished, both machines cleaned |
## 24.11 On real hardware
The first real rack will be the first test of:
- **BMCs**: vendor Redfish (iDRAC, iLO, XCC, Supermicro) — the boot override
in UEFI mode, ETag (`If-Match`) on PATCH where a BMC demands it, real
certificates through `BMC_CA`.
- **Network boot**: UEFI PXE (or HTTP boot) on the fabric NIC only, with PXE
off on the others; Secure Boot off, or the boot chain signed.
- **Drives**: NVMe sanitize, ATA sanitize and secure erase (and drives left
frozen by firmware), SAS sanitize — each on the models the site has.
- **Switches**: the site's own automation through `exec` or `http`, or SONiC
natively; uplinks set as trunks by the network team beforehand.
Before the first cluster: give hpcod a VLAN range and the cleaning VLAN,
trunk them to the head host, put the BMCs where the control plane can reach
them, turn off in-band BMC access on the machines, and run `hpcod verify`
until every machine is free.
Still to be built: native drivers for the switches sites actually have, and