ci / derle (push) Successful in 30s
Discovery already saw every node of a Proxmox cluster and placement could put a VM on any of them, but the template, the snippets and a simple SDN zone only worked on PVE_NODE, so a cluster could land where it could not be built. - Setup asks which nodes clusters may use (PVE_NODES; a multi-select in the TUI when Proxmox has more than one). Discovery offers only those. - Heads are placed on PVE_NODE only (head_node), where the template is, so no shared storage is needed; diskless compute nodes spread. - PVE_SDN_ZONE_TYPE (auto|simple|vxlan): more than one node makes the zone vxlan, every node a peer, MTU 1450. A zone of the wrong type is remade only while no cluster has a vnet in it. Guest fabric NICs take the bridge MTU through virtio (mtu = 1). - setup keeps nodes and head_node of its own site in sites.yaml, leaving the rest of the file as the operator wrote it. - verify checks the nodes are online and the zone matches. Run on the simulated Proxmox with the zone forced to vxlan: setup remade the zone, a two-node selftest passed, both compute NICs came up at 1450, and a DF ping of 1422 bytes passed between them while 1423 did not. Two real Proxmox nodes have not been tested. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
411 lines
19 KiB
Markdown
411 lines
19 KiB
Markdown
# 20. HPC-on-Demand — Architecture
|
||
|
||
A control plane that fronts several Proxmox clusters, picks one that satisfies a
|
||
requested hardware profile (InfiniBand, GPU, NVMe, core count…), and provisions
|
||
an HPC cluster on it of the kind documented in sections 01–10.
|
||
|
||
**Status: built.** The control plane, placement, the provisioning pipeline
|
||
and the `/v1/clusters` endpoints are implemented in [hpcod/](../hpcod/); a
|
||
cluster provisions cold from the template in ~134s. It ships as one binary
|
||
that installs itself (`hpcod setup`, see [hpcod/DEPLOY.md](../hpcod/DEPLOY.md)).
|
||
Leases are recorded and shown, but nothing tears a cluster down when one
|
||
expires — the reaper in 20.2 is not built. Section 20.11 records the build
|
||
order that was followed.
|
||
|
||
---
|
||
|
||
## 20.1 What this has to do
|
||
|
||
```
|
||
user / portal / API client
|
||
│ "give me 8 nodes, 2 GPUs each, InfiniBand, 14 days"
|
||
▼
|
||
┌─────────────────────────────────────────────┐
|
||
│ HPC-on-Demand control plane │
|
||
│ │
|
||
│ inventory ──▶ placement ──▶ provisioner │
|
||
│ (discovery) (filter+score) (TF+Ansible) │
|
||
│ ▲ │ │
|
||
└───────┼────────────────────────────┼────────┘
|
||
│ Proxmox API (read) │ Terraform + SSH
|
||
┌───────┴──────┬──────────────┬──────┴────────┐
|
||
▼ ▼ ▼ ▼
|
||
site-a site-b site-c site-d
|
||
GPU + IB plain eth NVMe heavy mixed
|
||
(3 nodes) (12 nodes) (4 nodes) (6 nodes)
|
||
```
|
||
|
||
Each provisioned tenant is a self-contained cluster: its own bridge, its own
|
||
subnet, its own Warewulf head node, its own Slurm. That is the structure this
|
||
repository already builds by hand — the control plane's job is to do it
|
||
repeatedly, on the right hardware, without collisions.
|
||
|
||
## 20.2 Components
|
||
|
||
| Component | Responsibility |
|
||
|---|---|
|
||
| **API server** | REST + auth, request validation, quota, lifecycle state machine |
|
||
| **Inventory** | Periodically polls every Proxmox cluster; stores nodes, capacity, capabilities |
|
||
| **Placement** | Turns a request into a chosen cluster + chosen nodes, or a clear refusal |
|
||
| **IPAM** | Allocates a bridge name and subnet per tenant; the collision-avoidance authority |
|
||
| **Provisioner** | Runs Terraform (VMs, vnet); the head configures itself on first boot |
|
||
| **State store** | PostgreSQL: tenants, clusters, allocations, applications, projects. Terraform state stays in one directory per cluster |
|
||
| **Reaper** | Enforces leases; tears clusters down on expiry. *Not built: an expired lease is shown, not acted on* |
|
||
|
||
Deliberately *not* a component: a scheduler across clusters. Slurm schedules
|
||
inside a tenant; this system allocates whole clusters, not jobs. Conflating the
|
||
two is how these systems become unmaintainable.
|
||
|
||
## 20.3 Capability discovery — and its real limits
|
||
|
||
Discovery reads the Proxmox API on each cluster:
|
||
|
||
| Source | Yields |
|
||
|---|---|
|
||
| `/nodes/{node}/status` | CPU model, socket/core count, total memory |
|
||
| `/nodes` | Per-node free memory, CPU load, online state |
|
||
| `/nodes/{node}/hardware/pci` | `class`, `vendor`, `device`, `device_name`, `iommugroup` |
|
||
| `/nodes/{node}/storage` | Storage types (`zfspool`, `lvmthin`, `nfs`), free space |
|
||
| `/cluster/status` | Node membership, quorum |
|
||
| `/cluster/resources` | Existing VM/CT load, so we do not oversubscribe |
|
||
|
||
Verified against the hv01 node in this lab:
|
||
|
||
```
|
||
VGA/GPU 0000:01:00.0 NVIDIA Corporation GM107GL [Quadro K620]
|
||
Ethernet 0000:07:00.0 Mellanox Technologies MT27710 [ConnectX-4 Lx]
|
||
Ethernet 0000:07:00.1 Mellanox Technologies MT27710 [ConnectX-4 Lx]
|
||
53 IOMMU groups; GPU alone in group 47 with only its own audio function
|
||
```
|
||
|
||
### The finding that shapes the design
|
||
|
||
**PCI class is not sufficient to detect InfiniBand.** The ConnectX-4 Lx above
|
||
reports class `0x0200` (Ethernet), because the *Lx* variant is Ethernet-only.
|
||
A ConnectX-6 in IB mode reports `0x0207`; the same card flipped to Ethernet mode
|
||
reports `0x0200`. Class alone therefore produces both false negatives (IB-capable
|
||
card currently in Ethernet mode) and false positives (RoCE treated as IB).
|
||
|
||
So discovery is layered, most reliable first:
|
||
|
||
1. **PCI class** — dependable for GPUs (`0x0300`, `0x0302`) and NVMe (`0x0108`).
|
||
2. **Curated `vendor:device` → capability map**, shipped with the orchestrator
|
||
and versioned like a hardware database. This is what distinguishes
|
||
ConnectX-4 Lx (Ethernet, RoCE) from ConnectX-6 (IB-capable).
|
||
3. **A tiny discovery agent** on each Proxmox node, reporting what the API
|
||
cannot see: `/sys/class/infiniband/*` (link layer, active speed), NVIDIA
|
||
driver and MIG state, NUMA topology, `vfio-pci` bindings.
|
||
|
||
Layers 1 and 2 need nothing installed. Layer 3 is optional but is the only way
|
||
to state "InfiniBand, 200 Gb/s, active" rather than "a card that could do IB".
|
||
|
||
**Recommendation:** treat auto-discovery as authoritative for *capacity* and
|
||
*presence*, and require layer 3 before a cluster may advertise `infiniband` as a
|
||
schedulable capability. Advertising IB on the strength of a PCI ID alone will
|
||
eventually hand someone a cluster whose fabric is not actually up.
|
||
|
||
### Passthrough viability
|
||
|
||
A GPU is only offerable if its IOMMU group contains nothing else that matters.
|
||
On hv01 the K620 sits in group 47 with just its own HDA function — clean. The
|
||
discovery record therefore carries `passthrough_safe: true|false` derived from
|
||
group membership, not merely "a GPU exists".
|
||
|
||
## 20.4 Data model
|
||
|
||
```
|
||
proxmox_cluster(id, name, endpoint, token_ref, state, last_seen)
|
||
pve_node(id, cluster_id, name, cores, mem_bytes, online, alloc_cores, alloc_mem)
|
||
device(id, pve_node_id, pci_id, class, vendor, device, iommu_group,
|
||
capability, passthrough_safe) -- capability: gpu|ib|nvme|roce
|
||
capability_map(vendor, device, capability, notes) -- curated, versioned
|
||
|
||
tenant(id, owner, name, state, lease_expires_at, spec_json)
|
||
allocation(tenant_id, cluster_id, bridge, subnet, vlan_tag)
|
||
allocated_node(tenant_id, pve_node_id, role, vmid, cores, mem, devices[])
|
||
```
|
||
|
||
`state` on `tenant` is the lifecycle: `requested → placed → provisioning →
|
||
ready → expiring → deleting → deleted`, plus `failed`. Every transition is
|
||
written before the side effect, so a crashed provisioner is resumable rather
|
||
than ambiguous.
|
||
|
||
### Request
|
||
|
||
```yaml
|
||
name: genomics-week12
|
||
lease: 14d
|
||
head: { cores: 4, memory_gb: 16, disk_gb: 200 }
|
||
compute:
|
||
count: 8
|
||
cores: 8
|
||
memory_gb: 64
|
||
require:
|
||
- capability: gpu
|
||
count: 2
|
||
vendor: nvidia
|
||
- capability: infiniband
|
||
min_speed_gbps: 100
|
||
prefer:
|
||
- capability: nvme
|
||
stack:
|
||
os: rocky9
|
||
scheduler: slurm
|
||
identity: freeipa # or: join-existing
|
||
```
|
||
|
||
`require` is a hard filter; `prefer` only affects scoring. Keeping them
|
||
separate is what lets the API answer "no cluster has 100 Gb IB" instead of
|
||
silently returning something slower.
|
||
|
||
## 20.5 Placement
|
||
|
||
Two phases, deliberately in this order:
|
||
|
||
**Filter** — eliminate the impossible. Cluster is healthy and quorate; every
|
||
`require` is satisfiable on nodes that are online; free cores/memory cover the
|
||
request with headroom; enough passthrough-safe devices are unallocated; a free
|
||
subnet exists.
|
||
|
||
**Score** — rank what remains:
|
||
|
||
```
|
||
score = w1 * capability_fit // penalise waste: do not burn an IB+GPU
|
||
// cluster on a request needing neither
|
||
+ w2 * free_capacity_ratio // prefer emptier clusters
|
||
+ w3 * packing_quality // fewer PVE nodes per tenant = less noise
|
||
- w4 * fragmentation_cost // avoid leaving unusable remainders
|
||
```
|
||
|
||
`capability_fit` is the one that matters and the one most such systems get
|
||
wrong. Scarce hardware must be reserved for requests that need it; a plain
|
||
CPU job placed on the only InfiniBand cluster is a scheduling failure even
|
||
though it "fits".
|
||
|
||
Selection is committed inside a transaction that increments the allocation
|
||
counters, so two concurrent requests cannot both win the last GPU.
|
||
|
||
## 20.5a Tenants and clusters are not the same thing
|
||
|
||
A tenant is who owns a cluster. A cluster is one provisioned installation.
|
||
One tenant may hold several at once, and the difference is not cosmetic:
|
||
everything that must not collide - the bridge, the subnet, the MAC prefix,
|
||
the VM names, the public hostname, the Slurm cluster name - is a property of
|
||
the cluster, not of its owner.
|
||
|
||
This was conflated in the first implementation. A single `tenant_id` drove
|
||
all of them, so a tenant asking for a second cluster while the first was
|
||
running would have been handed the same bridge, the same subnet and the same
|
||
MAC prefix - and Warewulf matches nodes by MAC, so the second cluster would
|
||
have broken the first rather than failing cleanly.
|
||
|
||
cluster_id 1-254 addressing: bridge, subnet, MACs, names, hostname
|
||
tenant_id attribution: tags, accounting, billing
|
||
|
||
The bound of 254 is therefore on clusters that exist at the same time, not
|
||
on tenants. A tenant running three clusters consumes three.
|
||
|
||
## 20.6 Tenant isolation
|
||
|
||
One Linux bridge and one /24 per tenant — the `vmbr6` pattern from section 01,
|
||
multiplied:
|
||
|
||
| Tenant | Bridge | Subnet | Head node |
|
||
|---|---|---|---|
|
||
| 1 | `vmbrT001` | 10.64.1.0/24 | 10.64.1.1 |
|
||
| 2 | `vmbrT002` | 10.64.2.0/24 | 10.64.2.1 |
|
||
| n | `vmbrT00n` | 10.64.n.0/24 | 10.64.n.1 |
|
||
|
||
Properties carried over from the working build, and the reasons they matter:
|
||
|
||
- **No IP on the Proxmox side.** Warewulf must own DHCP/TFTP/PXE for its
|
||
subnet; a second authority on the segment breaks PXE.
|
||
- **The head node is the tenant's router**, NATing out through the management
|
||
network — so tenants cannot reach each other even if they guess addresses.
|
||
- **PXE broadcasts stay inside the bridge**, which is what makes running many
|
||
Warewulf clusters on one hypervisor safe at all.
|
||
|
||
IPAM allocates from `10.64.0.0/10` (≈16k /24s), recorded in Postgres. The
|
||
bridge is created by Terraform and torn down with the tenant; a leaked bridge
|
||
is a leaked subnet, so deletion is verified rather than assumed.
|
||
|
||
That day arrived early, and the fabric is now an SDN vnet rather than a
|
||
bridge stanza written over SSH. The reason was not multi-node: appending to
|
||
`/etc/network/interfaces` on a hypervisor running other people's guests is a
|
||
poor way to work, and an early version of that code wrote a comment line
|
||
without its `#`, which would have taken the host's networking down at the
|
||
next reload. Proxmox owns the lifecycle now, and the module has no
|
||
provisioner blocks left.
|
||
|
||
Each cluster gets one `proxmox_sdn_vnet` named after it, in a zone shared by
|
||
the site and referenced rather than created — several Terraform states each
|
||
declaring the same zone would each believe they owned it. The vnet name is
|
||
the bridge a guest attaches to, so it is `c002`, not `vmbrC002`: Proxmox caps
|
||
vnet names at eight characters.
|
||
|
||
**Permissions.** Creating a vnet needs `SDN.Allocate` on the zone and can be
|
||
scoped to it. Applying needs it on `/sdn` and cannot be scoped at all,
|
||
because Proxmox applies the entire pending SDN configuration at once. Both
|
||
live in a separate role holding only the three SDN privileges, rather than
|
||
being added to the provisioner's role, which is bound at `/`. This is still
|
||
less than the mechanism it replaced: editing the hypervisor's network
|
||
configuration needed root SSH.
|
||
|
||
**Several nodes.** A `simple` zone gives every node its own isolated
|
||
bridge of the same name: correct for one hypervisor, and wrong the moment a
|
||
cluster spans two, because two nodes would get two unconnected L2 segments
|
||
and PXE would not cross. When a site uses more than one node of a Proxmox
|
||
cluster, setup makes the zone `vxlan`, with every node a peer; each vnet
|
||
carries the cluster id as its VNI. VXLAN costs 50 bytes a frame, so the
|
||
bridge is 1450, and the guests' NICs take the bridge's MTU through virtio
|
||
(`mtu = 1`). Without that a guest assumes 1500 and full-sized frames are
|
||
dropped at the bridge without an error.
|
||
|
||
Heads are not spread. The template lives on one node, and a clone cannot
|
||
cross nodes without shared storage, so placement puts every head on that
|
||
node (`head_node`) and spreads only the diskless compute nodes, over the
|
||
nodes the site lists (`nodes`). Both are site settings that setup keeps in
|
||
step with its answers.
|
||
|
||
The vxlan zone and the MTU path have been run end to end on one node,
|
||
where the bridge is still 1450 and an oversized frame would still be
|
||
dropped: a two-node cluster built, its nodes booted over PXE and ran
|
||
`srun -N 2`, both compute NICs came up at 1450, and between them a
|
||
1450-byte frame with DF set passed while 1451 did not. Traffic between two
|
||
Proxmox nodes has not been run: the lab has one.
|
||
|
||
## 20.7 Provisioning pipeline
|
||
|
||
Terraform for infrastructure, Ansible for configuration, with a hard boundary
|
||
between them.
|
||
|
||
```
|
||
placement decided, cluster allocated in Postgres
|
||
│
|
||
├─ tofu apply one state directory per cluster
|
||
│ • SDN vnet c<NNN>
|
||
│ • head node VM (cloned from the template; cloud-init vendor data
|
||
│ carries the cluster's inventory)
|
||
│ • N compute VMs (diskless, boot order=net0, PCI passthrough if requested)
|
||
│
|
||
├─ the head configures itself on first boot
|
||
│ hpcod-firstboot (role selfconfig) runs site.yml from the copy the
|
||
│ template carries: warewulf, node image, slurm, warewulf_nodes,
|
||
│ apps, ondemand, verify — the install-tagged half already done
|
||
│
|
||
├─ wait for the head's portal; publish it at c<NNN>.<CLUSTER_DOMAIN>
|
||
│
|
||
└─ state = ready
|
||
```
|
||
|
||
**Terraform** (OpenTofu) uses the `bpg/proxmox` provider, which covers VMs,
|
||
cloud-init, PCI passthrough (`hostpci`) and SDN. Each cluster has its own
|
||
state directory under `/var/lib/hpcod/terraform/envs`, so a failure touches
|
||
one cluster. The control plane runs one apply per cluster at a time, which
|
||
is what stops two writers racing; the state is not in Postgres.
|
||
|
||
**Ansible** roles are ports of the scripts in `scripts/`, which are already
|
||
proven end to end. Most of the work runs once, when setup builds the head
|
||
node template; what is specific to one cluster runs on the head itself at
|
||
first boot. The control plane never runs a playbook against a tenant. Each
|
||
role keeps the comments explaining *why* — particularly the twelve traps in
|
||
section 08, every one of which will otherwise be rediscovered.
|
||
|
||
Two rules worth stating because they are usually violated:
|
||
|
||
- Terraform never configures software; Ansible never creates infrastructure.
|
||
Mixing them is what makes these pipelines impossible to re-run.
|
||
- Both must be idempotent. Provisioning will be interrupted, and the recovery
|
||
path must be "run it again", not manual repair.
|
||
|
||
### MAC and VMID allocation
|
||
|
||
Warewulf matches nodes by MAC, so MACs must be deterministic and unique across
|
||
clusters. Derive them from the cluster id (§20.5a) and the node index, inside
|
||
the locally-administered range. VMIDs come from a per-cluster range recorded
|
||
in Postgres, never from `nextid`, which races.
|
||
|
||
## 20.8 Identity
|
||
|
||
Two modes, because both are legitimately wanted:
|
||
|
||
- **Dedicated** — a FreeIPA server per tenant, as built in section 04. Full
|
||
isolation; costs one extra VM and ~8 minutes of provisioning.
|
||
- **Shared** — tenants enrol against a central IPA with per-tenant groups and
|
||
HBAC rules restricting which hosts a group may log into.
|
||
|
||
Shared is cheaper and gives users one identity across clusters; dedicated is
|
||
the right answer when tenants must not see each other's user lists. The spec
|
||
field `identity: freeipa | join-existing` selects it.
|
||
|
||
Either way the stateless-node enrolment mechanism from section 04.3 applies
|
||
unchanged: per-node keytabs distributed through Warewulf overlays, because
|
||
`ipa-client-install` cannot run on a rootfs rebuilt every boot.
|
||
|
||
## 20.9 API surface
|
||
|
||
```
|
||
POST /v1/clusters submit a request → 202 + tenant id
|
||
GET /v1/clusters/{id} state, endpoints, progress
|
||
DELETE /v1/clusters/{id} tear down
|
||
POST /v1/clusters/{id}/extend extend the lease
|
||
GET /v1/capacity what could be satisfied right now
|
||
POST /v1/dry-run placement decision without provisioning
|
||
GET /v1/sites clusters, capabilities, utilisation
|
||
```
|
||
|
||
`/v1/dry-run` earns its place: it lets a user find out that no site has 100 Gb
|
||
InfiniBand *before* committing to a fourteen-day lease, and it makes the
|
||
placement logic testable in isolation.
|
||
|
||
**Implemented so far:** `/v1/sites`, `/v1/capacity`, `/v1/dry-run`, and
|
||
`POST`/`GET /v1/clusters`, `GET`/`DELETE /v1/clusters/{id}`. The portal's
|
||
create page takes the same path. A lease is extended from the portal's
|
||
cluster page; `POST /v1/clusters/{id}/extend` does not exist.
|
||
|
||
## 20.10 Failure modes to design for now
|
||
|
||
| Failure | Consequence if ignored | Mitigation |
|
||
|---|---|---|
|
||
| Provisioner dies mid-run | Orphaned VMs, leaked subnet | State written before side effects; resumable; reconciler sweeps orphans |
|
||
| Proxmox unreachable during discovery | Stale inventory, bad placement | `last_seen` timestamps; refuse placement on stale data |
|
||
| Two requests, one GPU | Double allocation | Allocation committed in a transaction |
|
||
| Tenant lease expires while jobs run | Angry users | Warn at T-24h; drain Slurm; then delete |
|
||
| Bridge not cleaned up | Subnet exhaustion | Deletion verified against Proxmox, not assumed |
|
||
| PCI ID map out of date | New card unusable, or IB wrongly claimed | Map is versioned and testable; layer-3 agent confirms |
|
||
| Terraform state corruption | Cannot delete a cluster | One state directory per cluster, one apply at a time; it is backed up with `/var/lib/hpcod` |
|
||
|
||
## 20.11 Suggested build order
|
||
|
||
Each phase should end in something demonstrable, on the hardware in this lab.
|
||
|
||
1. **Inventory + discovery** against hv01. Read-only, no provisioning. Proves
|
||
the capability model against real PCI data.
|
||
2. **Placement + `/v1/dry-run`.** Pure function over the inventory, heavily
|
||
unit-tested with synthetic multi-site fixtures. No Proxmox writes yet.
|
||
3. **Terraform module** producing the bridge, head node and compute VMs for one
|
||
tenant. Verified by hand-running Ansible afterwards.
|
||
4. **Ansible roles** ported from `scripts/`, ending in the same verification
|
||
`A99-verify.sh` already performs.
|
||
5. **API server + lifecycle**, including delete and the reconciler.
|
||
6. **Leases, quotas, multi-site**, and a second Proxmox to prove placement
|
||
actually discriminates.
|
||
|
||
Phases 1–2 carry nearly all the design risk and none of the destructive
|
||
operations, which is why they come first.
|
||
|
||
## 20.12 Open questions
|
||
|
||
- **Compute node RAM.** The Warewulf model unpacks the rootfs into RAM (§01.5,
|
||
§08.1). Every tenant node therefore needs ~2 GB before user workload. Does
|
||
the request specify usable memory or total, and who explains the difference?
|
||
- **GPU sharing.** Passthrough is whole-device. Fractional GPUs need MIG or
|
||
vGPU licensing — out of scope for a first version, but the data model should
|
||
not assume one device equals one tenant forever.
|
||
- **Image build time.** ~12 minutes per node image. Tenants with identical
|
||
stacks should share a prebuilt image; the cache key is the stack spec.
|
||
- **Storage beyond `/home`.** Real HPC wants scratch. Is that per-tenant NFS,
|
||
or does it come from an existing parallel filesystem the tenant mounts?
|
||
- **Billing.** Projects and the `cluster_usage` view now turn allocations into
|
||
hours held per project. Nothing prices them.
|