Commit Graph
8 Commits
Author SHA1 Message Date
Ilker ManapandClaude Opus 5.5 0fd55a862b MIG: a card in MIG mode is placed as its instances, each a GPU of class <card>-mig-<profile>
Discovery reports a card in MIG mode as its instances instead of the whole
card, on both paths: nvidia-smi (-L names them, -q -x gives their memory,
ids and processes) and NVML (GetMigMode, GetMaxMigDeviceCount,
GetMigDeviceHandleByIndex, behind an interface so it is tested with a fake).
Each instance has its MIG UUID, its own memory, and a class from the card's
and the profile: a100-80g-mig-3g.40gb. Placement numbers instances
1000 + 100 x card + instance and every view shows them as card/migN.

A replica on MIG runs on exactly one instance: a process opens one MIG
device and instances have no NVLink between them, so tp, pp, gpus or nodes
above one on a MIG class are refused in catalog validation and again in
placement, and the planner offers one instance or none. The agent gives
the engine CUDA_VISIBLE_DEVICES=MIG-<uuid> (no Vulkan device variable on
MIG). Memory and processes are per instance; heat, power and wear the
card's; utilisation is left out rather than reported as zero. A card in MIG
mode with nothing carved stays out of placement with the reason, and
llmgw doctor reports each card's mode and instances and warns of the states
in which nothing can run. ctl nodes, ctl status, the console and the plan
count devices by class. docs/install.md has a MIG section.

Written against fakes of nvidia-smi and NVML output; not yet run on MIG
hardware.

Co-Authored-By: Claude Opus 5.5 (1M context) <noreply@anthropic.com>
2026-10-05 00:01:14 +02:00
Ilker ManapandClaude Opus 5.5 20479a2d5f Find multi-node NVLink domains, place across them, and show them as racks
A GB200 NVL72 rack or an NVLink Switch system is a scale-up island: its
GPUs reach each other over NVLink whatever node they are in. Each GPU
now reports its fabric from nvidia-smi -q - state, status, ClusterUUID,
CliqueId, bandwidth - at registration and once a minute after, since a
fabric manager restarting drops every card out at once; and each node
reports nvidia-imex and its channels, without which the domain's GPUs
cannot share memory across nodes. A single machine's NVSwitch, which
reports a cluster of zeros, is no domain.

A replica spanning nodes is placed inside one domain first, on nodes
whose every card is joined and whose IMEX is up, and its shards are
told NCCL_MNNVL_ENABLE=1; InfiniBand is the fallback.

/admin/nvlink draws each domain as a rack - the NVLink Switch band on
top, light running down a backplane, trays of GPU chips that glow when
joined, pulse red when not, turn amber on degraded bandwidth - and
lists what keeps a tray out. A node's page shows its GPU-by-GPU NVLink
matrix, each card's NUMA node and nearest adapter, and its domain and
IMEX. doctor checks joining, bandwidth, IMEX and its channel; metrics
llmgw_gpu_nvlink_joined and llmgw_imex_up; /api/v1/nvlink.

Co-Authored-By: Claude Opus 5.5 (1M context) <noreply@anthropic.com>
2026-09-29 09:07:59 +02:00
Ilker ManapandClaude Opus 5.5 bf2d171e89 Read NVLink and GPU-to-adapter distance from nvidia-smi topo
The release binary is built without cgo, so without NVML, and NVML was
the only source of NVLink peers: on every NVLink machine the portable
agent reported none, and tensor-parallel groups were chosen by GPU index.
Discovery now reads `nvidia-smi topo -m` after either path, for the
NVLink peers (kept from NVML where it gave them), each card's NUMA node,
and how far each network adapter is from it - PIX, PXB, PHB, NODE or
SYS - which travels to the control plane as nic_paths for placement to
use. Both the NICn-with-legend layout of newer drivers and the
adapter-named columns of older ones are read.

Co-Authored-By: Claude Opus 5.5 (1M context) <noreply@anthropic.com>
2026-09-29 00:09:26 +02:00
Ilker ManapandClaude Opus 5 753f4e3265 Let a node say how much room it has left
CI / test (push) Failing after 1m31s
Disk was the one resource nothing reported. `statfs` was already being called
on every model directory, but only to ask whether the filesystem was a network
one — the free space it returns in the same struct was thrown away. So the
only way to find out why a node was filling up was to ssh to it, which is what
this system exists to avoid.

Reported per filesystem rather than per configured directory. Free space
belongs to the disk, not the path: two model directories on one disk are one
pool of bytes, and counting them separately would let the control plane add
24 GB to 24 GB and place a 40 GB model on a node that has 24.

Shared filesystems are summed separately from local ones and left out of a
node's own total. Space on a filer belongs to everyone mounting it, so twenty
nodes would otherwise each report the same free terabyte, and a scheduler
would place twenty models into room for one.

Nothing reported means nothing is known, everywhere: an agent too old to send
storage and a node with no model directories both send nothing, and both must
read as unknown rather than as a full disk. `ctl nodes` and the dashboard show
a dash, the metric is absent rather than zero, and a missing directory — which
is what an unmounted filer looks like — is skipped rather than reported as
having no space.

Shown as free out of total, because the first is useless without the second:
8 GB free is comfortable on a 10 TB filer and nearly full on a 10 GB root
partition, and only the second stops a model being placed.

Co-Authored-By: Claude Opus 5 (1M context) <noreply@anthropic.com>
2026-09-18 09:38:57 +02:00
Ilker ManapandClaude Opus 5 42fd0aa31e Export what the cluster is made of, not only what it is serving
CI / test (push) Successful in 1m28s
The router published twenty-two metric families about requests, endpoints,
admission and scoring — everything about traffic and nothing about the
machines carrying it. There was no way to graph GPU usage, watch a node go
unhealthy, see a fabric fill up, or answer "was the cluster full at the
time", which is the first question anyone asks after an incident. The
agents exported nothing at all.

Exported by the control plane rather than by each agent. It already holds
every number: hardware arrives at registration and state on each heartbeat,
so this is a map read away. One scrape target for a fleet of hundreds, no
Prometheus configuration per node, no firewall rule per machine, and
nothing new running on the nodes. On the same /metrics as the traffic
figures, because correlating "the cluster was full" with "requests were
queueing" should not need two systems.

A collector rather than gauges kept current by a ticker: the numbers are
derived from state that already exists, so computing them when asked is
simpler than maintaining a copy that can drift, and nothing runs between
scrapes.

GPU utilisation is new, and is the number people actually watch. Memory
used says a model is loaded; this says whether it is doing anything, and a
fleet at ninety percent occupancy and two percent utilisation is a fleet
holding models nobody is asking for.

Adding it caught two things. utilization.gpu goes last in the nvidia-smi
query and is optional, because a driver too old to know it returns a
shorter row — requiring it made an llmgw upgrade silently stop discovering
GPUs on an older node, which is far worse than not knowing how busy a card
is. And I gave the new protobuf field number 14, which ecc_errors already
had; buf lint is why that was a moment rather than a corrupted wire format.

Absent is kept distinct from zero throughout, for the same reason as
everywhere else here: an unreported utilisation shown as a flat zero reads
as an idle fleet rather than a missing measurement, and a replica nothing
has reported would be the most idle thing in the cluster.

Co-Authored-By: Claude Opus 5 (1M context) <noreply@anthropic.com>
2026-09-17 15:09:27 +02:00
Ilker ManapandClaude Opus 5 c13c567cc5 Know where the weights are, without owning the storage
CI / test (push) Successful in 1m32s
Storage will be different at every installation — Lustre, NFS over RDMA, an
image exported with SRP or NVMe-oF, local NVMe, an rsync — so llmgw observes
it rather than managing it. An agent told which directories to look in
reports what it can see; how the files got there is nobody's business here,
and a node told nothing reports nothing and behaves exactly as every node
did before this existed.

That fact buys two things. Placement prefers a node that already holds the
model over one that must first move tens of gigabytes, as a preference and
never a filter: fetching them is a valid answer, and refusing to place would
turn a slow start into no start at all. And ctl status shows what each
fabric holds.

Per fabric because fabrics are not connected to one another. Weights in
ib-a are not weights in ib-b — the only path between them is the management
network — so a model seeded into one fabric leaves the rest of the cluster
unable to serve it without a slow copy, and nothing said so before now. One
shared filer counts the same as twenty local copies, because "can this
fabric serve it" is the question being asked.

Three distinctions the tests hold to, because each is a way to get this
quietly wrong. A node that was never asked to look must rank with one that
looked and has nothing, or enabling the feature on a single node would
drain every other. An empty directory is not weights, because a
half-finished download looks exactly like one and would send placement to a
node whose engine then fails to load. And local storage is never mistaken
for shared: a filer read as local costs an unnecessary copy, while local
read as shared would have the cluster believe a model is everywhere when it
is on one node.

Co-Authored-By: Claude Opus 5 (1M context) <noreply@anthropic.com>
2026-09-17 08:21:16 +02:00
Ilker ManapandClaude Opus 5 3081c6f69b Place on nodes that can actually hold the model
CI / test (push) Successful in 1m23s
Placement had no idea how much memory a node has or a model needs. A CPU
profile has no card to be free, so eligibleNodes accepted every ready node:
Qwen2.5-Coder 14B, whose working set is about 24 GB, would have been placed
just as happily on one of the 8 GB nodes, which reports itself perfectly
healthy right up until the OOM killer arrives.

node_selector was yesterday's stopgap and it is the operator restating by
hand something the system can know. Agents now report MemTotal, profiles
declare min_memory_gb, and placement filters on it, naming what was short —
"has 8 GB of memory, needs 24" is actionable where "no candidates were
considered" is not. The label selector stays, because "this node is for
coding models" is a real thing to want to say that memory does not express.

Two deliberate non-exclusions. A profile with no requirement fits anywhere,
which is every profile that exists today. And a node that reports no memory
is still usable: an agent older than the field says nothing, and letting a
control plane upgrade quietly empty half a fleet is a worse failure than the
one this prevents.

ctl nodes grows a MEM column showing "-" rather than 0 for a node that did
not say, because an old agent is not a small machine.

Co-Authored-By: Claude Opus 5 (1M context) <noreply@anthropic.com>
2026-09-16 23:12:44 +02:00
ilkerandClaude Opus 5 6a13e3dddf Phase 2 (1/2): node discovery, engine adapters, process supervisor
CI / test (push) Successful in 45s
Everything here works without GPUs and is covered by tests. The control plane
connection is not built yet, so llmgw agent itself is still a stub and the phase
exit criterion is not met.

- discovery: IB from /sys/class/infiniband, parsing the formats sysfs actually
  uses and telling native InfiniBand from RoCE; GPUs via nvidia-smi, the
  cgo-free path, with health flags for uncorrected ECC and memory already held
  by another process. A node without IB is not an error, it is a single-node
  island.
- engines: vLLM and SGLang command and environment construction, kept free of
  process handling so it stays testable. The NCCL environment is the part the
  plan marks critical: NCCL_IB_HCA lists only the chosen fabric's adapters,
  because leaving it open lets NCCL pick an adapter on a fabric where the peer
  is unreachable, and the job then hangs instead of failing.
- validation before launch: no mixed GPU types in a tensor-parallel group, the
  node/GPU/TP arithmetic has to add up, and fp8 is refused below compute
  capability 8.9 rather than silently falling back to a slower path.
- supervisor: process groups, because engines fork workers that hold GPU memory
  and outlive a signal sent only to the leader; a bounded log tail, since engine
  output is the only diagnosis when loading fails; Starting separate from
  Loading, because a 70B model legitimately takes minutes; and orphan adoption
  through pid files fingerprinted with the command line, since pids get reused
  and adopting an unrelated process is worse than leaking the original.
- readiness is two questions: /health says the process is up, /v1/models says
  the weights loaded. Routing on /health alone sends traffic into a loading model.
- llmgw agent inventory reports what the scheduler would see on a node.

One plan correction: GPU class sizes come from the driver in GiB, which does not
always match the marketing name. An L40S is sold as 48GB and reports 44.99 GiB,
so its class is l40s-45g, not l40s-48g. Consistency matters more than matching
the box, because that number decides whether a model fits. Plan §2 and §5.1
updated.

Co-Authored-By: Claude Opus 5 (1M context) <noreply@anthropic.com>
2026-09-16 02:01:59 +02:00