MIG: a card in MIG mode is placed as its instances, each a GPU of class <card>-mig-<profile>
Discovery reports a card in MIG mode as its instances instead of the whole card, on both paths: nvidia-smi (-L names them, -q -x gives their memory, ids and processes) and NVML (GetMigMode, GetMaxMigDeviceCount, GetMigDeviceHandleByIndex, behind an interface so it is tested with a fake). Each instance has its MIG UUID, its own memory, and a class from the card's and the profile: a100-80g-mig-3g.40gb. Placement numbers instances 1000 + 100 x card + instance and every view shows them as card/migN. A replica on MIG runs on exactly one instance: a process opens one MIG device and instances have no NVLink between them, so tp, pp, gpus or nodes above one on a MIG class are refused in catalog validation and again in placement, and the planner offers one instance or none. The agent gives the engine CUDA_VISIBLE_DEVICES=MIG-<uuid> (no Vulkan device variable on MIG). Memory and processes are per instance; heat, power and wear the card's; utilisation is left out rather than reported as zero. A card in MIG mode with nothing carved stays out of placement with the reason, and llmgw doctor reports each card's mode and instances and warns of the states in which nothing can run. ctl nodes, ctl status, the console and the plan count devices by class. docs/install.md has a MIG section. Written against fakes of nvidia-smi and NVML output; not yet run on MIG hardware. Co-Authored-By: Claude Opus 5.5 (1M context) <noreply@anthropic.com>
This commit is contained in:
1 parent
e81f1cba4c
commit
0fd55a862b
39 files changed
+2587
-327
No files matched your search
+302
-182
File diff suppressed because it is too large.
Load diff
@@ -252,6 +252,25 @@ message GPU {
|
||||
string cluster_uuid = 19;
|
||||
string clique_id = 20;
|
||||
string fabric_bandwidth = 21;
|
||||
// mig is set when this is a MIG instance rather than a whole card. index
|
||||
// is then 1000 + 100 × card + device, uuid the instance's (MIG-…), and
|
||||
// memory the instance's share; utilization_percent stays zero, because no
|
||||
// driver measures it per instance.
|
||||
MIGDevice mig = 22;
|
||||
}
|
||||
|
||||
// MIGDevice is which card a MIG instance is carved from, and how.
|
||||
message MIGDevice {
|
||||
int32 parent_index = 1;
|
||||
string parent_uuid = 2;
|
||||
// parent_memory_total_mb is the whole card's: the class is named from it.
|
||||
int32 parent_memory_total_mb = 3;
|
||||
// device is the instance's number on its card, as nvidia-smi -L lists it.
|
||||
int32 device = 4;
|
||||
// profile is NVIDIA's name for the slice, like 3g.40gb.
|
||||
string profile = 5;
|
||||
int32 gpu_instance = 6;
|
||||
int32 compute_instance = 7;
|
||||
}
|
||||
|
||||
message FabricAttachment {
|
||||
|
||||
@@ -428,6 +428,71 @@ sudo llmgw doctor
|
||||
A `-nvml` build is still published beside the portable one; it reads NVLink
|
||||
from NVML directly, and needs a libc no older than the builder's.
|
||||
|
||||
### MIG, if you want to cut a card into pieces
|
||||
|
||||
An A100, A30, H100, H200 or later card can be split into MIG (Multi-Instance
|
||||
GPU) instances, each with its own memory, its own share of the card's compute
|
||||
and its own UUID. llmgw places a model on an instance as it would on a card,
|
||||
which makes MIG the way to run several small models on one large card without
|
||||
them competing for it.
|
||||
|
||||
**llmgw does not create the instances.** How a card is cut is your decision,
|
||||
made once with `nvidia-smi` on the node; the agent reads what is there when
|
||||
it starts:
|
||||
|
||||
```
|
||||
sudo nvidia-smi -i 0 -mig 1 # MIG mode on card 0; may need a reset
|
||||
sudo nvidia-smi mig -i 0 -lgip # the profiles this card offers
|
||||
sudo nvidia-smi mig -i 0 -cgi 3g.40gb,3g.40gb -C # two instances, each with its compute instance
|
||||
nvidia-smi -L # the instances, with their MIG- UUIDs
|
||||
sudo systemctl restart llmgw-agent # so it registers the new devices
|
||||
```
|
||||
|
||||
`-C` matters: a GPU instance with no compute instance inside it is not a
|
||||
device yet. Turning MIG on takes effect at the card's next reset
|
||||
(`nvidia-smi -i 0 -r` with nothing running on it, or a reboot), and instances
|
||||
do not survive a reboot unless something recreates them — NVIDIA's
|
||||
`mig-parted` or a systemd unit of your own.
|
||||
|
||||
**Classes.** A card in MIG mode is reported as its instances instead of as
|
||||
the whole card, and each instance's class is the card's class and the
|
||||
profile: two `3g.40gb` instances of an A100 80GB are two devices of class
|
||||
`a100-80g-mig-3g.40gb`, an H100's `1g.10gb+me` is `h100-80g-mig-1g.10gb-me`.
|
||||
`llmgw ctl nodes` lists the classes, and a profile names one like any other:
|
||||
|
||||
```yaml
|
||||
profiles:
|
||||
- name: mig
|
||||
engine: vllm
|
||||
gpu_class: a100-80g-mig-3g.40gb
|
||||
```
|
||||
|
||||
**One instance a replica.** A process can open only one MIG device, and
|
||||
instances have no NVLink or peer-to-peer access between them, so a replica on
|
||||
MIG runs on exactly one instance: `tp: 1`, one GPU, one node. A profile on a
|
||||
MIG class asking for more is refused when the model is added, with that
|
||||
reason. A model too large for one instance wants a larger profile or a whole
|
||||
card. `llmgw ctl model plan` and `ctl model serve` plan the same way: an
|
||||
instance is offered for a model it holds, and never several together.
|
||||
|
||||
**How they are numbered and shown.** Placement numbers card 0's instance 2 as
|
||||
device 1002 (1000 + 100 × card + instance), and every view shows it as
|
||||
`0/mig2`. The engine is given the instance by its UUID —
|
||||
`CUDA_VISIBLE_DEVICES=MIG-…` — which works for vLLM and for llama.cpp's CUDA
|
||||
build. llama.cpp's Vulkan build cannot see MIG instances at all.
|
||||
|
||||
**What is measured.** Each instance's memory is its own; temperature, power
|
||||
and wear are its card's, shown on each of its instances. Utilisation is not
|
||||
reported for an instance, because no driver measures it per instance: the
|
||||
console says `n/a on MIG`, and no `llmgw_gpu_utilization_percent` series is
|
||||
published for it rather than a zero.
|
||||
|
||||
`sudo llmgw doctor` lists each card's MIG mode and instances, and warns of a
|
||||
card in MIG mode with none created (nothing can run on it: CUDA will not open
|
||||
the whole card while MIG is on), of GPU instances with no compute instance,
|
||||
and of a mode change waiting for a reset. Such a card is also kept out of
|
||||
placement, with the reason, in `llmgw ctl nodes`.
|
||||
|
||||
### InfiniBand, if you have it
|
||||
|
||||
```
|
||||
|
||||
+28
-5
@@ -1202,18 +1202,20 @@ const (
|
||||
//
|
||||
// The interface NCCL bootstraps over is this node's, not the cluster's: the
|
||||
// control plane sends one name for every node, and a node whose management
|
||||
// network is on ens3 rather than eth0 would have NCCL bind nothing. And on
|
||||
// RoCE, which GID entry routes is a property of these adapters.
|
||||
// network is on ens3 rather than eth0 would have NCCL bind nothing. On RoCE,
|
||||
// which GID entry routes is a property of these adapters. And a MIG instance
|
||||
// is opened by its UUID, which only this node knows.
|
||||
func (a *Agent) localizeSpec(spec *engines.ShardSpec) {
|
||||
if a.cfg.MgmtInterface != "" {
|
||||
spec.MgmtInterface = a.cfg.MgmtInterface
|
||||
}
|
||||
a.mu.Lock()
|
||||
hcas, gpus := a.inv.HCAs, a.inv.GPUs
|
||||
a.mu.Unlock()
|
||||
spec.GPUUUIDs = migUUIDs(gpus, spec.GPUIndices)
|
||||
if len(spec.HCAs) == 0 {
|
||||
return
|
||||
}
|
||||
a.mu.Lock()
|
||||
hcas := a.inv.HCAs
|
||||
a.mu.Unlock()
|
||||
want := map[string]bool{}
|
||||
for _, h := range spec.HCAs {
|
||||
want[h] = true
|
||||
@@ -1232,6 +1234,27 @@ func (a *Agent) localizeSpec(spec *engines.ShardSpec) {
|
||||
}
|
||||
}
|
||||
|
||||
// migUUIDs names a shard's devices by UUID when one of them is a MIG
|
||||
// instance, and is nil otherwise: whole cards keep being given by index, as
|
||||
// they always were. A device this node does not have is left to fail where
|
||||
// it always has, in the engine, rather than guessed at here.
|
||||
func migUUIDs(gpus []discovery.GPU, indices []int) []string {
|
||||
var out []string
|
||||
mig := false
|
||||
for _, i := range indices {
|
||||
k := slices.IndexFunc(gpus, func(g discovery.GPU) bool { return g.Index == i })
|
||||
if k < 0 || gpus[k].UUID == "" {
|
||||
return nil
|
||||
}
|
||||
mig = mig || gpus[k].IsMIG()
|
||||
out = append(out, gpus[k].UUID)
|
||||
}
|
||||
if !mig {
|
||||
return nil
|
||||
}
|
||||
return out
|
||||
}
|
||||
|
||||
// ResolveManagement is the address and interface this node's agent would use,
|
||||
// found the way normalize finds them, for a tool that reports them.
|
||||
func ResolveManagement(c Config) (addr, iface string) {
|
||||
|
||||
@@ -47,6 +47,11 @@ type GPU struct {
|
||||
Fabric *GPUFabric `json:"fabric,omitempty"`
|
||||
// Health carries anything that should keep the GPU out of placement.
|
||||
Health GPUHealth `json:"health"`
|
||||
// MIG is set when this is a MIG instance rather than a whole card: its
|
||||
// Index is then MIGIndex's, its UUID the instance's (MIG-…), and its
|
||||
// memory the instance's share. Utilisation stays unreported, because no
|
||||
// driver measures it per instance.
|
||||
MIG *MIGDevice `json:"mig,omitempty"`
|
||||
}
|
||||
|
||||
// GPUHealth records conditions that make a GPU unsafe to schedule onto.
|
||||
@@ -94,8 +99,30 @@ func (g GPU) Class() string {
|
||||
}
|
||||
|
||||
// Round to the nearest GiB: vendors report 81559 MiB for an "80GB" card.
|
||||
gb := int(math.Round(float64(g.MemoryTotalMB) / 1024))
|
||||
return fmt.Sprintf("%s-%dg", model, gb)
|
||||
// A MIG instance is named from its card's memory and then its profile,
|
||||
// so two instances are one class only when both the card and the slice
|
||||
// are the same.
|
||||
mem := g.MemoryTotalMB
|
||||
if g.MIG != nil {
|
||||
mem = g.MIG.ParentMemoryTotalMB
|
||||
}
|
||||
gb := int(math.Round(float64(mem) / 1024))
|
||||
class := fmt.Sprintf("%s-%dg", model, gb)
|
||||
if g.MIG != nil {
|
||||
return migClass(class, g.MIG.Profile)
|
||||
}
|
||||
return class
|
||||
}
|
||||
|
||||
// normalizeBusID makes bus ids comparable: NVML reports them uppercase from one
|
||||
// call and lowercase from another, and sometimes with a shortened domain.
|
||||
func normalizeBusID(s string) string {
|
||||
s = strings.ToLower(strings.TrimSpace(s))
|
||||
// "0000:1b:00.0" and "00000000:1B:00.0" are the same device.
|
||||
if i := strings.Index(s, ":"); i > 0 {
|
||||
s = strings.TrimLeft(s[:i], "0") + s[i:]
|
||||
}
|
||||
return strings.TrimPrefix(s, ":")
|
||||
}
|
||||
|
||||
// MarshalJSON adds the derived class, so a consumer of the JSON does not have
|
||||
|
||||
@@ -14,7 +14,6 @@ package discovery
|
||||
import (
|
||||
"context"
|
||||
"fmt"
|
||||
"strings"
|
||||
|
||||
"github.com/NVIDIA/go-nvml/pkg/nvml"
|
||||
)
|
||||
@@ -83,11 +82,18 @@ func DiscoverGPUsNVML(_ context.Context) ([]GPU, error) {
|
||||
}
|
||||
|
||||
assessHealth(&g)
|
||||
gpus = append(gpus, g)
|
||||
// A card in MIG mode is its instances, not itself: CUDA will not
|
||||
// open the whole card while MIG is on.
|
||||
devs, _ := migFromNVML(g, nvmlCard{dev})
|
||||
gpus = append(gpus, devs...)
|
||||
}
|
||||
|
||||
// A second pass, because a link's remote end may be a GPU enumerated later.
|
||||
// A second pass, because a link's remote end may be a GPU enumerated
|
||||
// later. MIG instances have no NVLink of their own to use.
|
||||
for i := range gpus {
|
||||
if gpus[i].IsMIG() {
|
||||
continue
|
||||
}
|
||||
dev, ret := nvml.DeviceGetHandleByIndex(gpus[i].Index)
|
||||
if ret != nvml.SUCCESS {
|
||||
continue
|
||||
@@ -136,13 +142,73 @@ func busIDString(b []int8) string {
|
||||
return string(buf)
|
||||
}
|
||||
|
||||
// normalizeBusID makes bus ids comparable: NVML reports them uppercase from one
|
||||
// call and lowercase from another, and sometimes with a shortened domain.
|
||||
func normalizeBusID(s string) string {
|
||||
s = strings.ToLower(strings.TrimSpace(s))
|
||||
// "0000:1b:00.0" and "00000000:1B:00.0" are the same device.
|
||||
if i := strings.Index(s, ":"); i > 0 {
|
||||
s = strings.TrimLeft(s[:i], "0") + s[i:]
|
||||
// nvmlCard adapts an NVML device to what MIG discovery reads of it.
|
||||
type nvmlCard struct{ dev nvml.Device }
|
||||
|
||||
func (c nvmlCard) MIGMode() (current, pending, ok bool) {
|
||||
cur, pend, ret := c.dev.GetMigMode()
|
||||
if ret != nvml.SUCCESS {
|
||||
// NOT_SUPPORTED on a card without MIG, which is most of them.
|
||||
return false, false, false
|
||||
}
|
||||
return strings.TrimPrefix(s, ":")
|
||||
return cur == nvml.DEVICE_MIG_ENABLE, pend == nvml.DEVICE_MIG_ENABLE, true
|
||||
}
|
||||
|
||||
func (c nvmlCard) MaxMIGDevices() int {
|
||||
n, ret := c.dev.GetMaxMigDeviceCount()
|
||||
if ret != nvml.SUCCESS {
|
||||
return 0
|
||||
}
|
||||
return n
|
||||
}
|
||||
|
||||
func (c nvmlCard) MIGDevice(i int) (nvmlMIGInstance, bool) {
|
||||
h, ret := c.dev.GetMigDeviceHandleByIndex(i)
|
||||
if ret != nvml.SUCCESS {
|
||||
// NOT_FOUND for an index with no instance: the count is the most a
|
||||
// card can hold, not how many it has.
|
||||
return nil, false
|
||||
}
|
||||
return nvmlMIG{h}, true
|
||||
}
|
||||
|
||||
// nvmlMIG adapts a MIG device handle.
|
||||
type nvmlMIG struct{ dev nvml.Device }
|
||||
|
||||
func (m nvmlMIG) UUID() string {
|
||||
u, _ := m.dev.GetUUID()
|
||||
return u
|
||||
}
|
||||
|
||||
func (m nvmlMIG) Name() string {
|
||||
n, _ := m.dev.GetName()
|
||||
return n
|
||||
}
|
||||
|
||||
func (m nvmlMIG) Memory() (totalMB, usedMB int, ok bool) {
|
||||
mem, ret := m.dev.GetMemoryInfo()
|
||||
if ret != nvml.SUCCESS {
|
||||
return 0, 0, false
|
||||
}
|
||||
return int(mem.Total / (1 << 20)), int(mem.Used / (1 << 20)), true
|
||||
}
|
||||
|
||||
func (m nvmlMIG) Instances() (gpuInstance, computeInstance int) {
|
||||
gi, ret := m.dev.GetGpuInstanceId()
|
||||
if ret != nvml.SUCCESS {
|
||||
gi = -1
|
||||
}
|
||||
ci, ret := m.dev.GetComputeInstanceId()
|
||||
if ret != nvml.SUCCESS {
|
||||
ci = -1
|
||||
}
|
||||
return gi, ci
|
||||
}
|
||||
|
||||
func (m nvmlMIG) Attributes() (slices, memoryMB int, ok bool) {
|
||||
a, ret := m.dev.GetAttributes()
|
||||
if ret != nvml.SUCCESS {
|
||||
return 0, 0, false
|
||||
}
|
||||
return int(a.GpuInstanceSliceCount), int(a.MemorySizeMB), true
|
||||
}
|
||||
@@ -60,7 +60,33 @@ func DiscoverGPUsSMI(ctx context.Context, binary string) ([]GPU, error) {
|
||||
if err != nil {
|
||||
return nil, fmt.Errorf("running %s: %w", binary, err)
|
||||
}
|
||||
return parseSMI(string(out))
|
||||
cards, err := parseSMI(string(out))
|
||||
if err != nil || len(cards) == 0 {
|
||||
return cards, err
|
||||
}
|
||||
// The query lists whole cards, MIG mode or not. A card in MIG mode is
|
||||
// replaced by its instances, which only -L names and only the full
|
||||
// report sizes; asked only when some card could be in MIG mode, since
|
||||
// the report is the slowest thing nvidia-smi does.
|
||||
if !anyMIGCapable(cards) {
|
||||
return cards, nil
|
||||
}
|
||||
listed, report := readMIG(ctx, binary)
|
||||
return expandMIG(cards, listed, report), nil
|
||||
}
|
||||
|
||||
// anyMIGCapable reports whether any card could be in MIG mode: MIG began
|
||||
// with compute capability 8.0 (the A100). The consumer cards of the same
|
||||
// generations have none, but telling them apart by name is guesswork, and
|
||||
// asking one costs only two more nvidia-smi runs at registration.
|
||||
func anyMIGCapable(cards []GPU) bool {
|
||||
for _, c := range cards {
|
||||
major, _, _ := strings.Cut(c.ComputeCapability, ".")
|
||||
if n, err := strconv.Atoi(major); err == nil && n >= 8 {
|
||||
return true
|
||||
}
|
||||
}
|
||||
return false
|
||||
}
|
||||
|
||||
func parseSMI(out string) ([]GPU, error) {
|
||||
|
||||
@@ -5,6 +5,7 @@ import (
|
||||
"encoding/xml"
|
||||
"fmt"
|
||||
"os/exec"
|
||||
"slices"
|
||||
"strconv"
|
||||
"strings"
|
||||
)
|
||||
@@ -34,9 +35,16 @@ func GPUProcesses(ctx context.Context, binary string) (map[int][]int, error) {
|
||||
return parseGPUProcesses(out)
|
||||
}
|
||||
|
||||
// GPUMemory is one card's memory as nvidia-smi reports it at a moment: what
|
||||
// GPUMemory is one device's memory as nvidia-smi reports it at a moment: what
|
||||
// is allocated on it, and which processes hold how much of that.
|
||||
//
|
||||
// A device is what discovery reports: a whole card, or each MIG instance of a
|
||||
// card in MIG mode, in the same order, so the readings line up with the
|
||||
// inventory one for one.
|
||||
type GPUMemory struct {
|
||||
// Index is the device's number as placement knows it: the card's
|
||||
// nvidia-smi index, or MIGIndex's for an instance.
|
||||
Index int
|
||||
UsedMB int
|
||||
Procs []GPUProcess
|
||||
}
|
||||
@@ -66,48 +74,62 @@ func GPUMemoryByProcess(ctx context.Context, binary string) ([]GPUMemory, error)
|
||||
return parseGPUMemory(out)
|
||||
}
|
||||
|
||||
// smiLog is the part of nvidia-smi's XML report this reads: each GPU, in
|
||||
// index order, its memory and the processes on it.
|
||||
type smiLog struct {
|
||||
GPUs []struct {
|
||||
Used string `xml:"fb_memory_usage>used"`
|
||||
Processes []struct {
|
||||
PID string `xml:"pid"`
|
||||
Type string `xml:"type"`
|
||||
UsedMB string `xml:"used_memory"`
|
||||
} `xml:"processes>process_info"`
|
||||
} `xml:"gpu"`
|
||||
}
|
||||
|
||||
// parseGPUProcesses reads the report. GPUs are listed in index order, which
|
||||
// is nvidia-smi's own numbering — the one placement assigns by.
|
||||
// parseGPUProcesses reads the report, by device as placement numbers them:
|
||||
// nvidia-smi's index for a whole card, MIGIndex's for a MIG instance.
|
||||
func parseGPUProcesses(report []byte) (map[int][]int, error) {
|
||||
mem, err := parseGPUMemory(report)
|
||||
if err != nil {
|
||||
return nil, err
|
||||
}
|
||||
out := map[int][]int{}
|
||||
for i, g := range mem {
|
||||
for _, g := range mem {
|
||||
for _, p := range g.Procs {
|
||||
out[i] = append(out[i], p.PID)
|
||||
out[g.Index] = append(out[g.Index], p.PID)
|
||||
}
|
||||
}
|
||||
return out, nil
|
||||
}
|
||||
|
||||
// parseGPUMemory reads the report into each GPU's memory and its holders.
|
||||
// parseGPUMemory reads the report into each device's memory and its holders.
|
||||
//
|
||||
// Cards are listed in index order, which is nvidia-smi's own numbering. A
|
||||
// card in MIG mode is read as its instances, each with its own memory and
|
||||
// the processes nvidia-smi attributes to its GPU and compute instance: a
|
||||
// process on one instance is not on its neighbours, and the card's total
|
||||
// would have charged every instance with all of them.
|
||||
func parseGPUMemory(report []byte) ([]GPUMemory, error) {
|
||||
var log smiLog
|
||||
var log migLog
|
||||
if err := xml.Unmarshal(report, &log); err != nil {
|
||||
return nil, fmt.Errorf("reading nvidia-smi's report: %w", err)
|
||||
}
|
||||
out := make([]GPUMemory, len(log.GPUs))
|
||||
out := make([]GPUMemory, 0, len(log.GPUs))
|
||||
for i, g := range log.GPUs {
|
||||
out[i].UsedMB = mib(g.Used)
|
||||
for _, p := range g.Processes {
|
||||
if pid, err := strconv.Atoi(strings.TrimSpace(p.PID)); err == nil {
|
||||
out[i].Procs = append(out[i].Procs, GPUProcess{PID: pid, UsedMB: mib(p.UsedMB)})
|
||||
procs := func(gi, ci int) []GPUProcess {
|
||||
var ps []GPUProcess
|
||||
for _, p := range g.Processes {
|
||||
pid, err := strconv.Atoi(strings.TrimSpace(p.PID))
|
||||
if err != nil {
|
||||
continue
|
||||
}
|
||||
if gi >= 0 && (atoiOr(p.GPUInstance, -1) != gi || atoiOr(p.ComputeInstance, -1) != ci) {
|
||||
continue
|
||||
}
|
||||
ps = append(ps, GPUProcess{PID: pid, UsedMB: mib(p.UsedMB)})
|
||||
}
|
||||
return ps
|
||||
}
|
||||
if !enabled(g.Current) || len(g.Devices) == 0 {
|
||||
out = append(out, GPUMemory{Index: i, UsedMB: mib(g.Used), Procs: procs(-1, -1)})
|
||||
continue
|
||||
}
|
||||
devs := slices.Clone(g.Devices)
|
||||
slices.SortFunc(devs, func(a, b migLogDevice) int { return atoiOr(a.Index, -1) - atoiOr(b.Index, -1) })
|
||||
for _, d := range devs {
|
||||
out = append(out, GPUMemory{
|
||||
Index: MIGIndex(i, atoiOr(d.Index, 0)),
|
||||
UsedMB: mib(d.Used),
|
||||
Procs: procs(atoiOr(d.GPUInstance, -1), atoiOr(d.ComputeInstance, -1)),
|
||||
})
|
||||
}
|
||||
}
|
||||
return out, nil
|
||||
|
||||
@@ -57,8 +57,8 @@ func TestGPUMemoryIsReadPerProcess(t *testing.T) {
|
||||
t.Fatal(err)
|
||||
}
|
||||
want := []GPUMemory{
|
||||
{UsedMB: 14514, Procs: []GPUProcess{{PID: 71315, UsedMB: 4932}, {PID: 4100, UsedMB: 9500}}},
|
||||
{},
|
||||
{Index: 0, UsedMB: 14514, Procs: []GPUProcess{{PID: 71315, UsedMB: 4932}, {PID: 4100, UsedMB: 9500}}},
|
||||
{Index: 1},
|
||||
}
|
||||
if !reflect.DeepEqual(got, want) {
|
||||
t.Errorf("got %+v, want %+v", got, want)
|
||||
|
||||
@@ -0,0 +1,560 @@
|
||||
package discovery
|
||||
|
||||
// MIG — Multi-Instance GPU — carves one A100, H100 or later card into up to
|
||||
// seven instances, each with its own memory, its own share of the
|
||||
// multiprocessors and its own UUID. To CUDA an instance is a device of its
|
||||
// own, and to placement it is one too: a card in MIG mode is reported as its
|
||||
// instances instead of as the whole card, each a GPU of a class named from
|
||||
// the card's and the instance's profile ("a100-80g-mig-3g.40gb").
|
||||
//
|
||||
// llmgw does not create instances. Which split a card gets is an operator's
|
||||
// decision, made with nvidia-smi mig; discovery reads what is there.
|
||||
//
|
||||
// Two facts about MIG shape everything below. A process is given one MIG
|
||||
// device: CUDA enumerates a single instance however many are made visible.
|
||||
// And instances have no NVLink or peer-to-peer access between them. A replica
|
||||
// on MIG therefore runs on exactly one instance, never a tensor-parallel group
|
||||
// of them, and the catalog refuses a profile that asks for more.
|
||||
|
||||
import (
|
||||
"context"
|
||||
"encoding/xml"
|
||||
"fmt"
|
||||
"math"
|
||||
"os/exec"
|
||||
"regexp"
|
||||
"slices"
|
||||
"strconv"
|
||||
"strings"
|
||||
)
|
||||
|
||||
// MIGDevice is what a MIG instance carries beyond any GPU's fields: which
|
||||
// card it is carved from, and how.
|
||||
type MIGDevice struct {
|
||||
// ParentIndex is the card's nvidia-smi index, which is what its sensors,
|
||||
// topology and wear are reported by.
|
||||
ParentIndex int `json:"parent_index"`
|
||||
ParentUUID string `json:"parent_uuid,omitempty"`
|
||||
// ParentMemoryTotalMB is the whole card's memory: the class is named from
|
||||
// the card, so an instance of an 80 GB card is not mistaken for one of a
|
||||
// 40 GB card that happens to have the same profile name.
|
||||
ParentMemoryTotalMB int `json:"parent_memory_total_mb"`
|
||||
// Device is the instance's number on its card, as nvidia-smi -L lists it.
|
||||
Device int `json:"device"`
|
||||
// Profile is NVIDIA's name for the slice, like "3g.40gb": three of the
|
||||
// card's seven compute slices and forty gigabytes of its memory.
|
||||
Profile string `json:"profile"`
|
||||
// GPUInstance and ComputeInstance are the instance's ids in nvidia-smi
|
||||
// mig -lgi and -lci, which is how nvidia-smi attributes processes to it.
|
||||
GPUInstance int `json:"gpu_instance"`
|
||||
ComputeInstance int `json:"compute_instance"`
|
||||
}
|
||||
|
||||
// migIndexBase starts the numbers MIG instances are given.
|
||||
//
|
||||
// Placement, the agent protocol and every running shard name a node's devices
|
||||
// by an integer, which for a whole card is its nvidia-smi index. An instance
|
||||
// has none of its own, so it is given 1000 + 100 × card + device: card 0's
|
||||
// instance 2 is 1002, card 3's instance 0 is 1300. Readable, stable while the
|
||||
// instances are, and never one a whole card could have.
|
||||
const migIndexBase = 1000
|
||||
|
||||
// MIGIndex is the device number placement knows a MIG instance by.
|
||||
func MIGIndex(card, device int) int { return migIndexBase + 100*card + device }
|
||||
|
||||
// IsMIGIndex reports whether a device number names a MIG instance.
|
||||
func IsMIGIndex(i int) bool { return i >= migIndexBase }
|
||||
|
||||
// DeviceLabel is how a device number is shown to people: "3" for a whole
|
||||
// card, "0/mig2" for card 0's MIG instance 2.
|
||||
func DeviceLabel(i int) string {
|
||||
if !IsMIGIndex(i) {
|
||||
return strconv.Itoa(i)
|
||||
}
|
||||
i -= migIndexBase
|
||||
return fmt.Sprintf("%d/mig%d", i/100, i%100)
|
||||
}
|
||||
|
||||
// DeviceLabels is DeviceLabel for each of a list.
|
||||
func DeviceLabels(is []int) []string {
|
||||
out := make([]string, len(is))
|
||||
for k, i := range is {
|
||||
out[k] = DeviceLabel(i)
|
||||
}
|
||||
return out
|
||||
}
|
||||
|
||||
// IsMIG reports whether this GPU is a MIG instance rather than a whole card.
|
||||
func (g GPU) IsMIG() bool { return g.MIG != nil }
|
||||
|
||||
// CardIndex is the nvidia-smi index of the physical card this GPU is on: its
|
||||
// own index for a whole card, its parent's for a MIG instance.
|
||||
func (g GPU) CardIndex() int {
|
||||
if g.MIG != nil {
|
||||
return g.MIG.ParentIndex
|
||||
}
|
||||
return g.Index
|
||||
}
|
||||
|
||||
// migClassMarker joins a card's class to an instance's profile in a MIG
|
||||
// class: "a100-80g" + "-mig-" + "3g.40gb".
|
||||
const migClassMarker = "-mig-"
|
||||
|
||||
// IsMIGClass reports whether a GPU class names MIG instances.
|
||||
func IsMIGClass(class string) bool { return strings.Contains(class, migClassMarker) }
|
||||
|
||||
// migProfileClean keeps a profile name to what a class may hold: "1g.10gb+me"
|
||||
// becomes "1g.10gb-me".
|
||||
var migProfileClean = regexp.MustCompile(`[^a-z0-9.]+`)
|
||||
|
||||
// migClass is the class of a MIG instance: the card's class and the profile.
|
||||
func migClass(parentClass, profile string) string {
|
||||
p := migProfileClean.ReplaceAllString(strings.ToLower(strings.TrimSpace(profile)), "-")
|
||||
return parentClass + migClassMarker + strings.Trim(p, "-")
|
||||
}
|
||||
|
||||
// MIGProfileMemoryGB reads the memory out of a MIG class or profile:
|
||||
// 40 from "a100-80g-mig-3g.40gb" or "3g.40gb". Zero when there is none.
|
||||
func MIGProfileMemoryGB(s string) int {
|
||||
if i := strings.LastIndex(s, migClassMarker); i >= 0 {
|
||||
s = s[i+len(migClassMarker):]
|
||||
}
|
||||
m := migProfileMemory.FindStringSubmatch(strings.ToLower(s))
|
||||
if m == nil {
|
||||
return 0
|
||||
}
|
||||
gb, _ := strconv.Atoi(m[1])
|
||||
return gb
|
||||
}
|
||||
|
||||
var migProfileMemory = regexp.MustCompile(`^\d+g\.(\d+)gb`)
|
||||
|
||||
// --- nvidia-smi -L ---
|
||||
|
||||
// listedMIG is one MIG instance as nvidia-smi -L lists it.
|
||||
type listedMIG struct {
|
||||
Device int
|
||||
Profile string
|
||||
UUID string
|
||||
}
|
||||
|
||||
var (
|
||||
// "GPU 0: NVIDIA A100-SXM4-80GB (UUID: GPU-5d5ba0d6-...)"
|
||||
smiListGPU = regexp.MustCompile(`^GPU (\d+):`)
|
||||
// " MIG 3g.40gb Device 0: (UUID: MIG-c6d4f1ef-...)". Drivers before
|
||||
// R470 name the instance MIG-GPU-<card uuid>/<gi>/<ci>, which CUDA of that
|
||||
// era takes in the same place, so the UUID is read as whatever it is.
|
||||
smiListMIG = regexp.MustCompile(`^\s+MIG\s+(\S+)\s+Device\s+(\d+):\s*\(UUID:\s*([^)\s]+)\)`)
|
||||
)
|
||||
|
||||
// parseSMIList reads nvidia-smi -L into each card's MIG instances, by the
|
||||
// card's index, in device order. A card with none is absent.
|
||||
func parseSMIList(out string) map[int][]listedMIG {
|
||||
res := map[int][]listedMIG{}
|
||||
card := -1
|
||||
for _, line := range strings.Split(out, "\n") {
|
||||
if m := smiListGPU.FindStringSubmatch(line); m != nil {
|
||||
card, _ = strconv.Atoi(m[1])
|
||||
continue
|
||||
}
|
||||
m := smiListMIG.FindStringSubmatch(line)
|
||||
if m == nil || card < 0 {
|
||||
continue
|
||||
}
|
||||
dev, _ := strconv.Atoi(m[2])
|
||||
res[card] = append(res[card], listedMIG{Device: dev, Profile: m[1], UUID: m[3]})
|
||||
}
|
||||
for c := range res {
|
||||
slices.SortFunc(res[c], func(a, b listedMIG) int { return a.Device - b.Device })
|
||||
}
|
||||
return res
|
||||
}
|
||||
|
||||
// --- nvidia-smi -q -x ---
|
||||
|
||||
// migLog is the part of nvidia-smi's XML report MIG is read from: each card's
|
||||
// mode, and each instance's ids and memory.
|
||||
type migLog struct {
|
||||
GPUs []migLogGPU `xml:"gpu"`
|
||||
}
|
||||
|
||||
type migLogGPU struct {
|
||||
ID string `xml:"id,attr"`
|
||||
Current string `xml:"mig_mode>current_mig"`
|
||||
Pending string `xml:"mig_mode>pending_mig"`
|
||||
Devices []migLogDevice `xml:"mig_devices>mig_device"`
|
||||
// Processes carry the GPU and compute instance they run in on a card
|
||||
// in MIG mode, and "N/A" for both otherwise.
|
||||
Processes []struct {
|
||||
GPUInstance string `xml:"gpu_instance_id"`
|
||||
ComputeInstance string `xml:"compute_instance_id"`
|
||||
PID string `xml:"pid"`
|
||||
UsedMB string `xml:"used_memory"`
|
||||
} `xml:"processes>process_info"`
|
||||
Used string `xml:"fb_memory_usage>used"`
|
||||
}
|
||||
|
||||
type migLogDevice struct {
|
||||
Index string `xml:"index"`
|
||||
GPUInstance string `xml:"gpu_instance_id"`
|
||||
ComputeInstance string `xml:"compute_instance_id"`
|
||||
Total string `xml:"fb_memory_usage>total"`
|
||||
Used string `xml:"fb_memory_usage>used"`
|
||||
}
|
||||
|
||||
// migState is one card's MIG mode and instances from the report.
|
||||
type migState struct {
|
||||
BusID string
|
||||
Enabled bool
|
||||
PendingEnabled bool
|
||||
Devices []migReported
|
||||
}
|
||||
|
||||
// migReported is one instance as the report describes it.
|
||||
type migReported struct {
|
||||
Device, GPUInstance, ComputeInstance int
|
||||
TotalMB, UsedMB int
|
||||
}
|
||||
|
||||
// enabled reads nvidia-smi's mode words: "Enabled", "Disabled", "N/A".
|
||||
func enabled(s string) bool { return strings.EqualFold(strings.TrimSpace(s), "Enabled") }
|
||||
|
||||
func atoiOr(s string, def int) int {
|
||||
n, err := strconv.Atoi(strings.TrimSpace(s))
|
||||
if err != nil {
|
||||
return def
|
||||
}
|
||||
return n
|
||||
}
|
||||
|
||||
// parseMIGReport reads each card's MIG state from the XML report, in the
|
||||
// report's order, which is nvidia-smi's index order.
|
||||
func parseMIGReport(report []byte) ([]migState, error) {
|
||||
var log migLog
|
||||
if err := xml.Unmarshal(report, &log); err != nil {
|
||||
return nil, fmt.Errorf("reading nvidia-smi's report: %w", err)
|
||||
}
|
||||
out := make([]migState, len(log.GPUs))
|
||||
for i, g := range log.GPUs {
|
||||
out[i] = migState{BusID: g.ID, Enabled: enabled(g.Current), PendingEnabled: enabled(g.Pending)}
|
||||
for _, d := range g.Devices {
|
||||
out[i].Devices = append(out[i].Devices, migReported{
|
||||
Device: atoiOr(d.Index, -1), GPUInstance: atoiOr(d.GPUInstance, -1),
|
||||
ComputeInstance: atoiOr(d.ComputeInstance, -1),
|
||||
TotalMB: mib(d.Total), UsedMB: mib(d.Used),
|
||||
})
|
||||
}
|
||||
slices.SortFunc(out[i].Devices, func(a, b migReported) int { return a.Device - b.Device })
|
||||
}
|
||||
return out, nil
|
||||
}
|
||||
|
||||
// --- putting it together ---
|
||||
|
||||
// migProblemNoInstances keeps a card in MIG mode with nothing carved from it
|
||||
// out of placement: CUDA cannot use the whole card while MIG is on, and
|
||||
// there is no instance to use instead.
|
||||
const migProblemNoInstances = "MIG is enabled with no instances created: nothing can run on it " +
|
||||
"until instances are created (nvidia-smi mig -cgi … -C) or MIG is turned off"
|
||||
|
||||
// migProblemUnnamed is a card whose instances exist but could not be named:
|
||||
// an engine is given an instance by its UUID, and without one it cannot be.
|
||||
const migProblemUnnamed = "MIG is enabled and has instances, but nvidia-smi -L did not name them, " +
|
||||
"so none can be given to an engine"
|
||||
|
||||
// expandMIG replaces each card in MIG mode with its instances.
|
||||
//
|
||||
// listed is nvidia-smi -L's instances by card, which names them; report is
|
||||
// the XML report's state per card, which gives their memory and ids. Either
|
||||
// may be missing: -L alone still says which instances exist, and the report
|
||||
// alone still says a card is in MIG mode, so a card it says has instances
|
||||
// that -L did not name is kept as the whole card with the reason, rather
|
||||
// than placed as a card CUDA will not open.
|
||||
func expandMIG(cards []GPU, listed map[int][]listedMIG, report []migState) []GPU {
|
||||
if len(listed) == 0 && !slices.ContainsFunc(report, func(s migState) bool { return s.Enabled }) {
|
||||
return cards
|
||||
}
|
||||
byBus := map[string]migState{}
|
||||
for _, s := range report {
|
||||
byBus[normalizeBusID(s.BusID)] = s
|
||||
}
|
||||
out := make([]GPU, 0, len(cards))
|
||||
for pos, c := range cards {
|
||||
st, ok := byBus[normalizeBusID(c.PCIBusID)]
|
||||
if !ok && pos < len(report) {
|
||||
st = report[pos]
|
||||
}
|
||||
devs := listed[c.Index]
|
||||
if !st.Enabled && len(devs) == 0 {
|
||||
out = append(out, c)
|
||||
continue
|
||||
}
|
||||
if len(devs) == 0 {
|
||||
p := migProblemNoInstances
|
||||
if len(st.Devices) > 0 {
|
||||
p = migProblemUnnamed
|
||||
}
|
||||
c.Health.Problems = append(c.Health.Problems, p)
|
||||
out = append(out, c)
|
||||
continue
|
||||
}
|
||||
for _, d := range devs {
|
||||
var rep migReported
|
||||
found := false
|
||||
for _, r := range st.Devices {
|
||||
if r.Device == d.Device {
|
||||
rep, found = r, true
|
||||
}
|
||||
}
|
||||
mig := migInstance(c, d.Device, d.Profile, d.UUID)
|
||||
if found {
|
||||
mig.MIG.GPUInstance, mig.MIG.ComputeInstance = rep.GPUInstance, rep.ComputeInstance
|
||||
mig.MemoryTotalMB, mig.MemoryUsedMB = rep.TotalMB, rep.UsedMB
|
||||
}
|
||||
if mig.MemoryTotalMB == 0 {
|
||||
// The profile says it to the gigabyte, which is close enough
|
||||
// to place by when the report could not be read.
|
||||
mig.MemoryTotalMB = MIGProfileMemoryGB(d.Profile) * 1024
|
||||
}
|
||||
assessHealth(&mig)
|
||||
out = append(out, mig)
|
||||
}
|
||||
}
|
||||
return out
|
||||
}
|
||||
|
||||
// migInstance builds a MIG instance of card: everything about the card that
|
||||
// is shared — driver, compute capability, NUMA node, bus, temperature and
|
||||
// ECC errors — and nothing that is not. Not NVLink, which an instance cannot
|
||||
// use; not utilisation, which no driver reports per instance; and not the
|
||||
// card's memory or problems, which the instance's own replace.
|
||||
func migInstance(card GPU, device int, profile, uuid string) GPU {
|
||||
g := GPU{
|
||||
Index: MIGIndex(card.Index, device), UUID: uuid,
|
||||
Name: strings.TrimSpace(card.Name + " MIG " + profile),
|
||||
ComputeCapability: card.ComputeCapability, NUMANode: card.NUMANode,
|
||||
PCIBusID: card.PCIBusID, DriverVersion: card.DriverVersion, CUDAVersion: card.CUDAVersion,
|
||||
NICPaths: card.NICPaths, Fabric: card.Fabric,
|
||||
Health: GPUHealth{ECCErrors: card.Health.ECCErrors, TemperatureC: card.Health.TemperatureC},
|
||||
MIG: &MIGDevice{
|
||||
ParentIndex: card.Index, ParentUUID: card.UUID, ParentMemoryTotalMB: card.MemoryTotalMB,
|
||||
Device: device, Profile: profile, GPUInstance: -1, ComputeInstance: -1,
|
||||
},
|
||||
}
|
||||
return g
|
||||
}
|
||||
|
||||
// readMIG asks nvidia-smi for what expandMIG needs. A failure of either
|
||||
// command leaves its half empty, which expandMIG is written to take.
|
||||
func readMIG(ctx context.Context, binary string) (map[int][]listedMIG, []migState) {
|
||||
var listed map[int][]listedMIG
|
||||
if out, err := exec.CommandContext(ctx, binary, "-L").Output(); err == nil {
|
||||
listed = parseSMIList(string(out))
|
||||
}
|
||||
var report []migState
|
||||
if out, err := exec.CommandContext(ctx, binary, "-q", "-x").Output(); err == nil {
|
||||
report, _ = parseMIGReport(out)
|
||||
}
|
||||
return listed, report
|
||||
}
|
||||
|
||||
// --- NVML ---
|
||||
|
||||
// nvmlMIGCard is the part of an NVML device MIG discovery reads, behind an
|
||||
// interface so the logic is tested without a driver: gpu_nvml.go adapts
|
||||
// nvml.Device to it.
|
||||
type nvmlMIGCard interface {
|
||||
// MIGMode is nvmlDeviceGetMigMode; ok is false on a card without MIG.
|
||||
MIGMode() (current, pending, ok bool)
|
||||
// MaxMIGDevices is nvmlDeviceGetMaxMigDeviceCount.
|
||||
MaxMIGDevices() int
|
||||
// MIGDevice is nvmlDeviceGetMigDeviceHandleByIndex; ok is false for an
|
||||
// index with no instance behind it, which is how NVML says so.
|
||||
MIGDevice(i int) (nvmlMIGInstance, bool)
|
||||
}
|
||||
|
||||
// nvmlMIGInstance is one MIG device handle.
|
||||
type nvmlMIGInstance interface {
|
||||
UUID() string
|
||||
// Name is "NVIDIA A100-SXM4-80GB MIG 3g.40gb" on the drivers that name
|
||||
// MIG devices, which is where the profile is read from.
|
||||
Name() string
|
||||
Memory() (totalMB, usedMB int, ok bool)
|
||||
Instances() (gpuInstance, computeInstance int)
|
||||
// Slices and MemoryMB are the instance's attributes, which name the
|
||||
// profile on a driver whose device name does not.
|
||||
Attributes() (slices, memoryMB int, ok bool)
|
||||
}
|
||||
|
||||
var nvmlMIGName = regexp.MustCompile(`MIG\s+(\S+)\s*$`)
|
||||
|
||||
// migFromNVML is what one card is to placement under NVML: its instances if
|
||||
// it is in MIG mode, itself if it is not. isMIG says which.
|
||||
func migFromNVML(card GPU, dev nvmlMIGCard) (out []GPU, isMIG bool) {
|
||||
current, _, ok := dev.MIGMode()
|
||||
if !ok || !current {
|
||||
return []GPU{card}, false
|
||||
}
|
||||
n := dev.MaxMIGDevices()
|
||||
for i := range n {
|
||||
h, ok := dev.MIGDevice(i)
|
||||
if !ok {
|
||||
continue
|
||||
}
|
||||
profile := ""
|
||||
if m := nvmlMIGName.FindStringSubmatch(h.Name()); m != nil {
|
||||
profile = m[1]
|
||||
} else if n, mem, ok := h.Attributes(); ok {
|
||||
// The convention NVIDIA's names follow: compute slices, then the
|
||||
// memory in whole gigabytes.
|
||||
profile = fmt.Sprintf("%dg.%dgb", n, int(math.Round(float64(mem)/1024)))
|
||||
}
|
||||
g := migInstance(card, i, profile, h.UUID())
|
||||
g.MIG.GPUInstance, g.MIG.ComputeInstance = h.Instances()
|
||||
if total, used, ok := h.Memory(); ok {
|
||||
g.MemoryTotalMB, g.MemoryUsedMB = total, used
|
||||
} else {
|
||||
g.MemoryTotalMB = MIGProfileMemoryGB(profile) * 1024
|
||||
}
|
||||
assessHealth(&g)
|
||||
out = append(out, g)
|
||||
}
|
||||
if len(out) == 0 {
|
||||
card.Health.Problems = append(card.Health.Problems, migProblemNoInstances)
|
||||
return []GPU{card}, true
|
||||
}
|
||||
return out, true
|
||||
}
|
||||
|
||||
// --- what the doctor reports ---
|
||||
|
||||
// MIGCard is one card's MIG state, as `llmgw doctor` reports it.
|
||||
type MIGCard struct {
|
||||
Index int `json:"index"`
|
||||
Name string `json:"name,omitempty"`
|
||||
// Enabled is the mode in force; PendingEnabled the mode after the next
|
||||
// reset of the card, which differs from it until the card is reset.
|
||||
Enabled bool `json:"enabled"`
|
||||
PendingEnabled bool `json:"pending_enabled"`
|
||||
// Instances are the MIG devices an engine can be given, as nvidia-smi -L
|
||||
// lists them.
|
||||
Instances []MIGListed `json:"instances,omitempty"`
|
||||
// GPUInstances and ComputeInstances are nvidia-smi mig -lgi and -lci: a
|
||||
// GPU instance with no compute instance in it is not a device yet.
|
||||
GPUInstances []MIGInstance `json:"gpu_instances,omitempty"`
|
||||
ComputeInstances []MIGInstance `json:"compute_instances,omitempty"`
|
||||
}
|
||||
|
||||
// MIGListed is one instance an engine can be given.
|
||||
type MIGListed struct {
|
||||
Device int `json:"device"`
|
||||
Profile string `json:"profile"`
|
||||
UUID string `json:"uuid"`
|
||||
}
|
||||
|
||||
// MIGInstance is one row of nvidia-smi mig -lgi or -lci.
|
||||
type MIGInstance struct {
|
||||
GPU int `json:"gpu"`
|
||||
Profile string `json:"profile"`
|
||||
// ProfileID is NVIDIA's number for the profile.
|
||||
ProfileID int `json:"profile_id"`
|
||||
// GPUInstance is the GPU instance's id; ComputeInstance the compute
|
||||
// instance's within it, -1 in a -lgi row.
|
||||
GPUInstance int `json:"gpu_instance"`
|
||||
ComputeInstance int `json:"compute_instance"`
|
||||
Placement string `json:"placement,omitempty"`
|
||||
}
|
||||
|
||||
var (
|
||||
// -lgi: "| 0 MIG 3g.40gb 9 2 4:4 |"
|
||||
migLGIRow = regexp.MustCompile(`^\|\s*(\d+)\s+MIG\s+(\S+)\s+(\d+)\s+(\d+)\s+(\d+:\d+)\s*\|`)
|
||||
// -lci: "| 0 1 MIG 3g.40gb 2 0 0:3 |"
|
||||
migLCIRow = regexp.MustCompile(`^\|\s*(\d+)\s+(\d+)\s+MIG\s+(\S+)\s+(\d+)\s+(\d+)\s+(\d+:\d+)\s*\|`)
|
||||
)
|
||||
|
||||
// ParseMIGInstances reads nvidia-smi mig -lgi or -lci, whichever it is
|
||||
// given: the two tables differ by the GPU instance column -lci adds. "No GPU
|
||||
// instances found" and the like are no rows, not an error.
|
||||
func ParseMIGInstances(out string) []MIGInstance {
|
||||
var res []MIGInstance
|
||||
for _, line := range strings.Split(out, "\n") {
|
||||
line = strings.TrimSpace(line)
|
||||
if m := migLCIRow.FindStringSubmatch(line); m != nil {
|
||||
res = append(res, MIGInstance{
|
||||
GPU: atoiOr(m[1], -1), GPUInstance: atoiOr(m[2], -1), Profile: m[3],
|
||||
ProfileID: atoiOr(m[4], -1), ComputeInstance: atoiOr(m[5], -1), Placement: m[6],
|
||||
})
|
||||
continue
|
||||
}
|
||||
if m := migLGIRow.FindStringSubmatch(line); m != nil {
|
||||
res = append(res, MIGInstance{
|
||||
GPU: atoiOr(m[1], -1), Profile: m[2], ProfileID: atoiOr(m[3], -1),
|
||||
GPUInstance: atoiOr(m[4], -1), ComputeInstance: -1, Placement: m[5],
|
||||
})
|
||||
}
|
||||
}
|
||||
return res
|
||||
}
|
||||
|
||||
// DiscoverMIG reads every card's MIG state for the doctor: the mode from the
|
||||
// XML report, the devices from -L, the instances from nvidia-smi mig. Only
|
||||
// cards that support MIG are listed, and an error is returned only when the
|
||||
// report itself cannot be read.
|
||||
func DiscoverMIG(ctx context.Context, binary string) ([]MIGCard, error) {
|
||||
out, err := exec.CommandContext(ctx, binary, "-q", "-x").Output()
|
||||
if err != nil {
|
||||
return nil, fmt.Errorf("running %s -q -x: %w", binary, err)
|
||||
}
|
||||
var list, lgi, lci string
|
||||
if b, err := exec.CommandContext(ctx, binary, "-L").Output(); err == nil {
|
||||
list = string(b)
|
||||
}
|
||||
// nvidia-smi mig exits non-zero when there is nothing to list, with the
|
||||
// table or the reason on its output either way.
|
||||
b, _ := exec.CommandContext(ctx, binary, "mig", "-lgi").CombinedOutput()
|
||||
lgi = string(b)
|
||||
b, _ = exec.CommandContext(ctx, binary, "mig", "-lci").CombinedOutput()
|
||||
lci = string(b)
|
||||
return buildMIGCards(out, list, lgi, lci)
|
||||
}
|
||||
|
||||
// buildMIGCards is DiscoverMIG from the commands' output.
|
||||
func buildMIGCards(report []byte, list, lgi, lci string) ([]MIGCard, error) {
|
||||
var log struct {
|
||||
GPUs []struct {
|
||||
Name string `xml:"product_name"`
|
||||
Current string `xml:"mig_mode>current_mig"`
|
||||
Pending string `xml:"mig_mode>pending_mig"`
|
||||
} `xml:"gpu"`
|
||||
}
|
||||
if err := xml.Unmarshal(report, &log); err != nil {
|
||||
return nil, fmt.Errorf("reading nvidia-smi's report: %w", err)
|
||||
}
|
||||
listed := parseSMIList(list)
|
||||
gis, cis := ParseMIGInstances(lgi), ParseMIGInstances(lci)
|
||||
var out []MIGCard
|
||||
for i, g := range log.GPUs {
|
||||
cur, pend := strings.TrimSpace(g.Current), strings.TrimSpace(g.Pending)
|
||||
// A card without MIG says N/A, or nothing on a driver that predates
|
||||
// it; neither is worth a line.
|
||||
if !enabled(cur) && !enabled(pend) && !strings.EqualFold(cur, "Disabled") {
|
||||
continue
|
||||
}
|
||||
c := MIGCard{Index: i, Name: strings.TrimSpace(g.Name), Enabled: enabled(cur), PendingEnabled: enabled(pend)}
|
||||
for _, l := range listed[i] {
|
||||
c.Instances = append(c.Instances, MIGListed(l))
|
||||
}
|
||||
for _, gi := range gis {
|
||||
if gi.GPU == i && gi.ComputeInstance < 0 {
|
||||
c.GPUInstances = append(c.GPUInstances, gi)
|
||||
}
|
||||
}
|
||||
for _, ci := range cis {
|
||||
if ci.GPU == i && ci.ComputeInstance >= 0 {
|
||||
c.ComputeInstances = append(c.ComputeInstances, ci)
|
||||
}
|
||||
}
|
||||
out = append(out, c)
|
||||
}
|
||||
return out, nil
|
||||
}
|
||||
@@ -0,0 +1,418 @@
|
||||
package discovery
|
||||
|
||||
import (
|
||||
"encoding/json"
|
||||
"os"
|
||||
"path/filepath"
|
||||
"reflect"
|
||||
"slices"
|
||||
"strings"
|
||||
"testing"
|
||||
)
|
||||
|
||||
// Two A100 80GB cards: card 0 in MIG mode, cut into two 3g.40gb instances,
|
||||
// card 1 whole. What nvidia-smi prints for that machine, by command. None of
|
||||
// it is from real MIG hardware, which this was written without; the shapes
|
||||
// follow NVIDIA's documentation and the output of drivers R470 to R550.
|
||||
const (
|
||||
migQuery = `0, GPU-5d5ba0d6-d33d-2b2c-524d-9e3d8d2b8a77, NVIDIA A100-SXM4-80GB, 81920, 0, 8.0, 00000000:07:00.0, 550.54.15, 31, 0, [N/A]
|
||||
1, GPU-1f2e3d4c-5b6a-7980-a1b2-c3d4e5f60718, NVIDIA A100-SXM4-80GB, 81920, 0, 8.0, 00000000:0F:00.0, 550.54.15, 33, 0, 0
|
||||
`
|
||||
migList = `GPU 0: NVIDIA A100-SXM4-80GB (UUID: GPU-5d5ba0d6-d33d-2b2c-524d-9e3d8d2b8a77)
|
||||
MIG 3g.40gb Device 0: (UUID: MIG-c6d4f1ef-42e4-5de3-91c7-45d71c87eb3f)
|
||||
MIG 3g.40gb Device 1: (UUID: MIG-0f7c3a2e-9d1b-5a8e-b3c4-1e2f3a4b5c6d)
|
||||
GPU 1: NVIDIA A100-SXM4-80GB (UUID: GPU-1f2e3d4c-5b6a-7980-a1b2-c3d4e5f60718)
|
||||
`
|
||||
migReport = `<?xml version="1.0" ?>
|
||||
<nvidia_smi_log>
|
||||
<driver_version>550.54.15</driver_version>
|
||||
<gpu id="00000000:07:00.0">
|
||||
<product_name>NVIDIA A100-SXM4-80GB</product_name>
|
||||
<mig_mode><current_mig>Enabled</current_mig><pending_mig>Enabled</pending_mig></mig_mode>
|
||||
<mig_devices>
|
||||
<mig_device>
|
||||
<index>1</index>
|
||||
<gpu_instance_id>1</gpu_instance_id>
|
||||
<compute_instance_id>0</compute_instance_id>
|
||||
<device_attributes><shared><multiprocessor_count>42</multiprocessor_count></shared></device_attributes>
|
||||
<fb_memory_usage><total>40192 MiB</total><reserved>0 MiB</reserved><used>21000 MiB</used><free>19192 MiB</free></fb_memory_usage>
|
||||
</mig_device>
|
||||
<mig_device>
|
||||
<index>0</index>
|
||||
<gpu_instance_id>2</gpu_instance_id>
|
||||
<compute_instance_id>0</compute_instance_id>
|
||||
<fb_memory_usage><total>40192 MiB</total><reserved>0 MiB</reserved><used>37 MiB</used><free>40155 MiB</free></fb_memory_usage>
|
||||
</mig_device>
|
||||
</mig_devices>
|
||||
<fb_memory_usage><total>81920 MiB</total><used>21037 MiB</used></fb_memory_usage>
|
||||
<processes>
|
||||
<process_info>
|
||||
<gpu_instance_id>1</gpu_instance_id>
|
||||
<compute_instance_id>0</compute_instance_id>
|
||||
<pid>4100</pid><type>C</type><process_name>vllm</process_name>
|
||||
<used_memory>20900 MiB</used_memory>
|
||||
</process_info>
|
||||
</processes>
|
||||
</gpu>
|
||||
<gpu id="00000000:0F:00.0">
|
||||
<product_name>NVIDIA A100-SXM4-80GB</product_name>
|
||||
<mig_mode><current_mig>Disabled</current_mig><pending_mig>Disabled</pending_mig></mig_mode>
|
||||
<mig_devices>None</mig_devices>
|
||||
<fb_memory_usage><total>81920 MiB</total><used>300 MiB</used></fb_memory_usage>
|
||||
<processes>
|
||||
<process_info>
|
||||
<gpu_instance_id>N/A</gpu_instance_id>
|
||||
<compute_instance_id>N/A</compute_instance_id>
|
||||
<pid>5200</pid><type>C</type><used_memory>250 MiB</used_memory>
|
||||
</process_info>
|
||||
</processes>
|
||||
</gpu>
|
||||
</nvidia_smi_log>`
|
||||
migLGI = `+-------------------------------------------------------+
|
||||
| GPU instances: |
|
||||
| GPU Name Profile Instance Placement |
|
||||
| ID ID Start:Size |
|
||||
|=======================================================|
|
||||
| 0 MIG 3g.40gb 9 1 4:4 |
|
||||
+-------------------------------------------------------+
|
||||
| 0 MIG 3g.40gb 9 2 0:4 |
|
||||
+-------------------------------------------------------+
|
||||
`
|
||||
migLCI = `+--------------------------------------------------------------------+
|
||||
| Compute instances: |
|
||||
| GPU GPU Name Profile Instance Placement |
|
||||
| Instance ID ID Start:Size |
|
||||
| ID |
|
||||
|====================================================================|
|
||||
| 0 1 MIG 3g.40gb 2 0 0:3 |
|
||||
+--------------------------------------------------------------------+
|
||||
| 0 2 MIG 3g.40gb 2 0 0:3 |
|
||||
+--------------------------------------------------------------------+
|
||||
`
|
||||
)
|
||||
|
||||
func migMachine(t *testing.T) []GPU {
|
||||
t.Helper()
|
||||
cards, err := parseSMI(migQuery)
|
||||
if err != nil {
|
||||
t.Fatal(err)
|
||||
}
|
||||
report, err := parseMIGReport([]byte(migReport))
|
||||
if err != nil {
|
||||
t.Fatal(err)
|
||||
}
|
||||
return expandMIG(cards, parseSMIList(migList), report)
|
||||
}
|
||||
|
||||
func TestACardInMIGModeIsReportedAsItsInstancesInsteadOfItself(t *testing.T) {
|
||||
gpus := migMachine(t)
|
||||
var got []string
|
||||
for _, g := range gpus {
|
||||
got = append(got, DeviceLabel(g.Index)+" "+g.Class())
|
||||
}
|
||||
want := []string{"0/mig0 a100-80g-mig-3g.40gb", "0/mig1 a100-80g-mig-3g.40gb", "1 a100-80g"}
|
||||
if !slices.Equal(got, want) {
|
||||
t.Fatalf("devices = %q, want %q", got, want)
|
||||
}
|
||||
|
||||
mig := gpus[1]
|
||||
if mig.Index != 1001 || mig.UUID != "MIG-0f7c3a2e-9d1b-5a8e-b3c4-1e2f3a4b5c6d" {
|
||||
t.Errorf("instance 1 is %d %s; an engine is given it by that UUID", mig.Index, mig.UUID)
|
||||
}
|
||||
if mig.MemoryTotalMB != 40192 || mig.MemoryUsedMB != 21000 {
|
||||
t.Errorf("instance 1 memory %d/%d, want its own 21000/40192 rather than the card's",
|
||||
mig.MemoryUsedMB, mig.MemoryTotalMB)
|
||||
}
|
||||
if m := mig.MIG; m == nil || m.ParentIndex != 0 || m.Device != 1 || m.Profile != "3g.40gb" ||
|
||||
m.GPUInstance != 1 || m.ComputeInstance != 0 || m.ParentUUID != "GPU-5d5ba0d6-d33d-2b2c-524d-9e3d8d2b8a77" {
|
||||
t.Errorf("instance 1's parentage: %+v", mig.MIG)
|
||||
}
|
||||
if mig.ComputeCapability != "8.0" || mig.DriverVersion != "550.54.15" || mig.Health.TemperatureC != 31 {
|
||||
t.Errorf("what the card and its instances share was not carried: %+v", mig)
|
||||
}
|
||||
// Twenty gigabytes in use on an instance is a foreign tenant there, and
|
||||
// only there: instance 0 next to it is free.
|
||||
if mig.Health.OK() || !gpus[0].Health.OK() {
|
||||
t.Errorf("foreign memory judged per instance: 0 %v, 1 %v", gpus[0].Health.Problems, mig.Health.Problems)
|
||||
}
|
||||
// No driver reports utilisation per instance, and none is made up.
|
||||
if mig.UtilizationPercent != 0 {
|
||||
t.Errorf("an instance reported utilisation %d", mig.UtilizationPercent)
|
||||
}
|
||||
if gpus[2].IsMIG() || gpus[2].Index != 1 || gpus[2].CardIndex() != 1 || gpus[0].CardIndex() != 0 {
|
||||
t.Errorf("the whole card beside it changed: %+v", gpus[2])
|
||||
}
|
||||
}
|
||||
|
||||
func TestAMIGInstanceSurvivesTheTripToTheControlPlaneWithItsClass(t *testing.T) {
|
||||
g := migMachine(t)[0]
|
||||
b, err := json.Marshal(g)
|
||||
if err != nil {
|
||||
t.Fatal(err)
|
||||
}
|
||||
if !strings.Contains(string(b), `"class":"a100-80g-mig-3g.40gb"`) {
|
||||
t.Errorf("the JSON carries no class for the instance: %s", b)
|
||||
}
|
||||
var back GPU
|
||||
if err := json.Unmarshal(b, &back); err != nil {
|
||||
t.Fatal(err)
|
||||
}
|
||||
if back.Class() != g.Class() || !reflect.DeepEqual(back.MIG, g.MIG) {
|
||||
t.Errorf("came back as %s %+v", back.Class(), back.MIG)
|
||||
}
|
||||
}
|
||||
|
||||
func TestMIGClassesAreNamedFromTheCardAndTheProfile(t *testing.T) {
|
||||
for _, c := range []struct {
|
||||
name string
|
||||
cardMB int
|
||||
profile string
|
||||
want string
|
||||
}{
|
||||
{"NVIDIA A100-SXM4-80GB MIG 3g.40gb", 81920, "3g.40gb", "a100-80g-mig-3g.40gb"},
|
||||
// The same profile name on a 40 GB card is another class: its
|
||||
// instance is the same size, but the card is not, and neither is
|
||||
// the set of profiles that card can be cut to.
|
||||
{"NVIDIA A100-SXM4-40GB MIG 3g.20gb", 40960, "3g.20gb", "a100-40g-mig-3g.20gb"},
|
||||
{"NVIDIA H100 80GB HBM3 MIG 1g.10gb+me", 81559, "1g.10gb+me", "h100-80g-mig-1g.10gb-me"},
|
||||
{"NVIDIA H100 80GB HBM3 MIG 7g.80gb", 81559, "7g.80gb", "h100-80g-mig-7g.80gb"},
|
||||
} {
|
||||
g := GPU{Name: c.name, MemoryTotalMB: 10000, MIG: &MIGDevice{ParentMemoryTotalMB: c.cardMB, Profile: c.profile}}
|
||||
if got := g.Class(); got != c.want {
|
||||
t.Errorf("%s -> %s, want %s", c.name, got, c.want)
|
||||
}
|
||||
if !IsMIGClass(g.Class()) {
|
||||
t.Errorf("%s is not recognised as a MIG class", g.Class())
|
||||
}
|
||||
}
|
||||
if IsMIGClass("a100-80g") || IsMIGClass("6000-24g") {
|
||||
t.Error("a whole card's class was taken for a MIG one")
|
||||
}
|
||||
if MIGProfileMemoryGB("a100-80g-mig-3g.40gb") != 40 || MIGProfileMemoryGB("1g.10gb+me") != 10 || MIGProfileMemoryGB("a100-80g") != 0 {
|
||||
t.Error("the instance's memory is misread from its profile")
|
||||
}
|
||||
}
|
||||
|
||||
func TestDeviceNumbersAreShownAsCardAndInstance(t *testing.T) {
|
||||
for i, want := range map[int]string{0: "0", 7: "7", MIGIndex(0, 2): "0/mig2", MIGIndex(3, 0): "3/mig0", 1302: "3/mig2"} {
|
||||
if got := DeviceLabel(i); got != want {
|
||||
t.Errorf("DeviceLabel(%d) = %s, want %s", i, got, want)
|
||||
}
|
||||
}
|
||||
if IsMIGIndex(15) || !IsMIGIndex(MIGIndex(0, 0)) {
|
||||
t.Error("whole cards and instances are told apart wrongly")
|
||||
}
|
||||
}
|
||||
|
||||
func TestACardInMIGModeWithNoInstancesIsKeptOutOfPlacement(t *testing.T) {
|
||||
cards, _ := parseSMI(migQuery)
|
||||
report, _ := parseMIGReport([]byte(strings.Replace(migReport,
|
||||
migReport[strings.Index(migReport, "<mig_devices>"):strings.Index(migReport, "</mig_devices>")+len("</mig_devices>")],
|
||||
"<mig_devices>None</mig_devices>", 1)))
|
||||
gpus := expandMIG(cards, parseSMIList("GPU 0: NVIDIA A100-SXM4-80GB (UUID: GPU-x)\nGPU 1: NVIDIA A100-SXM4-80GB (UUID: GPU-y)\n"), report)
|
||||
if len(gpus) != 2 || gpus[0].IsMIG() {
|
||||
t.Fatalf("got %+v", gpus)
|
||||
}
|
||||
// CUDA will not open the whole card while MIG is on, and there is no
|
||||
// instance to open instead: placing anything here fails at start.
|
||||
if gpus[0].Health.OK() || !strings.Contains(gpus[0].Health.Problems[0], "no instances") {
|
||||
t.Errorf("card 0's problems: %v", gpus[0].Health.Problems)
|
||||
}
|
||||
if !gpus[1].Health.OK() {
|
||||
t.Errorf("card 1, not in MIG mode, was flagged: %v", gpus[1].Health.Problems)
|
||||
}
|
||||
|
||||
// Instances the report sees but -L could not name cannot be given to an
|
||||
// engine either; the card says why.
|
||||
report, _ = parseMIGReport([]byte(migReport))
|
||||
gpus = expandMIG(cards, nil, report)
|
||||
if len(gpus) != 2 || gpus[0].Health.OK() || !strings.Contains(gpus[0].Health.Problems[0], "did not name") {
|
||||
t.Errorf("with -L failing: %+v", gpus)
|
||||
}
|
||||
}
|
||||
|
||||
func TestInstancesAreFoundFromTheListAloneWhenTheReportCannotBeRead(t *testing.T) {
|
||||
cards, _ := parseSMI(migQuery)
|
||||
gpus := expandMIG(cards, parseSMIList(migList), nil)
|
||||
if len(gpus) != 3 || !gpus[0].IsMIG() || gpus[0].MemoryTotalMB != 40*1024 {
|
||||
t.Errorf("without the report: %+v", gpus)
|
||||
}
|
||||
}
|
||||
|
||||
func TestAnOlderDriversInstanceUUIDIsTakenAsItIs(t *testing.T) {
|
||||
// R450 and R460 name an instance by its card and ids, and CUDA of that
|
||||
// era takes exactly that in CUDA_VISIBLE_DEVICES.
|
||||
l := parseSMIList("GPU 0: A100-SXM4-40GB (UUID: GPU-5d5ba0d6-d33d-2b2c-524d-9e3d8d2b8a77)\n" +
|
||||
" MIG 1g.5gb Device 0: (UUID: MIG-GPU-5d5ba0d6-d33d-2b2c-524d-9e3d8d2b8a77/7/0)\n")
|
||||
if len(l[0]) != 1 || l[0][0].UUID != "MIG-GPU-5d5ba0d6-d33d-2b2c-524d-9e3d8d2b8a77/7/0" || l[0][0].Profile != "1g.5gb" {
|
||||
t.Errorf("parsed %+v", l)
|
||||
}
|
||||
}
|
||||
|
||||
func TestProcessesOnAMIGCardAreChargedToTheirOwnInstance(t *testing.T) {
|
||||
mem, err := parseGPUMemory([]byte(migReport))
|
||||
if err != nil {
|
||||
t.Fatal(err)
|
||||
}
|
||||
want := []GPUMemory{
|
||||
{Index: 1000, UsedMB: 37},
|
||||
{Index: 1001, UsedMB: 21000, Procs: []GPUProcess{{PID: 4100, UsedMB: 20900}}},
|
||||
{Index: 1, UsedMB: 300, Procs: []GPUProcess{{PID: 5200, UsedMB: 250}}},
|
||||
}
|
||||
if !reflect.DeepEqual(mem, want) {
|
||||
t.Errorf("got %+v\nwant %+v", mem, want)
|
||||
}
|
||||
// In the order discovery reports the devices, so a heartbeat's readings
|
||||
// line up with the inventory one for one.
|
||||
gpus := migMachine(t)
|
||||
for i := range gpus {
|
||||
if mem[i].Index != gpus[i].Index {
|
||||
t.Errorf("reading %d is for device %d, inventory has %d", i, mem[i].Index, gpus[i].Index)
|
||||
}
|
||||
}
|
||||
procs, _ := parseGPUProcesses([]byte(migReport))
|
||||
if !reflect.DeepEqual(procs, map[int][]int{1001: {4100}, 1: {5200}}) {
|
||||
t.Errorf("processes by device: %v", procs)
|
||||
}
|
||||
}
|
||||
|
||||
func TestAMIGInstanceTakesItsCardsPlaceInTheTopologyButNoNVLink(t *testing.T) {
|
||||
gpus := migMachine(t)
|
||||
topo := Topology{
|
||||
NVLink: map[int]map[int]int{0: {1: 12}, 1: {0: 12}},
|
||||
NUMA: map[int]int{0: 0, 1: 1},
|
||||
NICPath: map[int]map[string]string{0: {"mlx5_0": "PIX"}},
|
||||
}
|
||||
topo.Apply(gpus)
|
||||
if len(gpus[0].NVLinkPeers) != 0 || len(gpus[1].NVLinkPeers) != 0 {
|
||||
t.Errorf("MIG instances were given NVLink peers: %v %v", gpus[0].NVLinkPeers, gpus[1].NVLinkPeers)
|
||||
}
|
||||
if gpus[1].NUMANode != 0 || gpus[1].NICPaths["mlx5_0"] != "PIX" {
|
||||
t.Errorf("instance 1 did not take its card's NUMA node and adapters: %+v", gpus[1])
|
||||
}
|
||||
if gpus[2].NUMANode != 1 || !slices.Equal(gpus[2].NVLinkPeers, []int{0}) {
|
||||
t.Errorf("the whole card's topology: %+v", gpus[2])
|
||||
}
|
||||
}
|
||||
|
||||
func TestMIGInstancesAreDiscoveredThroughNvidiaSMI(t *testing.T) {
|
||||
// The real code path against a stub binary that answers each command as
|
||||
// the machine above would.
|
||||
dir := t.TempDir()
|
||||
stub := filepath.Join(dir, "nvidia-smi")
|
||||
script := "#!/bin/sh\ncase \"$1\" in\n" +
|
||||
"-L) cat <<'EOF'\n" + migList + "EOF\n;;\n" +
|
||||
"-q) cat <<'EOF'\n" + migReport + "\nEOF\n;;\n" +
|
||||
"*) cat <<'EOF'\n" + migQuery + "EOF\n;;\nesac\n"
|
||||
if err := os.WriteFile(stub, []byte(script), 0o755); err != nil {
|
||||
t.Fatal(err)
|
||||
}
|
||||
gpus, err := DiscoverGPUsSMI(t.Context(), stub)
|
||||
if err != nil {
|
||||
t.Fatal(err)
|
||||
}
|
||||
inv := Inventory{GPUs: gpus}
|
||||
if !slices.Equal(inv.Classes(), []string{"a100-80g", "a100-80g-mig-3g.40gb"}) || len(gpus) != 3 {
|
||||
t.Errorf("classes %v from %d devices", inv.Classes(), len(gpus))
|
||||
}
|
||||
}
|
||||
|
||||
// fakeMIGCard is NVML's view of one card, as nvmlDeviceGetMigMode,
|
||||
// nvmlDeviceGetMaxMigDeviceCount and nvmlDeviceGetMigDeviceHandleByIndex
|
||||
// would give it.
|
||||
type fakeMIGCard struct {
|
||||
mode, pending, supported bool
|
||||
max int
|
||||
devs map[int]fakeMIGInstance
|
||||
}
|
||||
|
||||
func (c fakeMIGCard) MIGMode() (bool, bool, bool) { return c.mode, c.pending, c.supported }
|
||||
func (c fakeMIGCard) MaxMIGDevices() int { return c.max }
|
||||
func (c fakeMIGCard) MIGDevice(i int) (nvmlMIGInstance, bool) {
|
||||
d, ok := c.devs[i]
|
||||
return d, ok
|
||||
}
|
||||
|
||||
type fakeMIGInstance struct {
|
||||
uuid, name string
|
||||
total, used int
|
||||
gi, ci int
|
||||
slices, attrMem int
|
||||
}
|
||||
|
||||
func (m fakeMIGInstance) UUID() string { return m.uuid }
|
||||
func (m fakeMIGInstance) Name() string { return m.name }
|
||||
func (m fakeMIGInstance) Memory() (int, int, bool) {
|
||||
return m.total, m.used, m.total > 0
|
||||
}
|
||||
func (m fakeMIGInstance) Instances() (int, int) { return m.gi, m.ci }
|
||||
func (m fakeMIGInstance) Attributes() (int, int, bool) {
|
||||
return m.slices, m.attrMem, m.slices > 0
|
||||
}
|
||||
|
||||
func TestNVMLReportsACardInMIGModeAsItsInstances(t *testing.T) {
|
||||
card := GPU{Index: 2, UUID: "GPU-card", Name: "NVIDIA H100 80GB HBM3", MemoryTotalMB: 81559,
|
||||
ComputeCapability: "9.0", NUMANode: 1, Health: GPUHealth{TemperatureC: 40}}
|
||||
// Seven slots, three filled, one of them on a driver that does not put
|
||||
// the profile in the device's name.
|
||||
dev := fakeMIGCard{mode: true, pending: true, supported: true, max: 7, devs: map[int]fakeMIGInstance{
|
||||
0: {uuid: "MIG-aaa", name: "NVIDIA H100 80GB HBM3 MIG 3g.40gb", total: 40448, used: 10, gi: 2, ci: 0},
|
||||
1: {uuid: "MIG-bbb", name: "NVIDIA H100 80GB HBM3 MIG 3g.40gb", total: 40448, used: 10, gi: 1, ci: 0},
|
||||
4: {uuid: "MIG-ccc", name: "NVIDIA H100 80GB HBM3", total: 9984, gi: 9, ci: 0, slices: 1, attrMem: 9984},
|
||||
}}
|
||||
gpus, isMIG := migFromNVML(card, dev)
|
||||
if !isMIG || len(gpus) != 3 {
|
||||
t.Fatalf("got %d devices, MIG %v", len(gpus), isMIG)
|
||||
}
|
||||
var classes []string
|
||||
for _, g := range gpus {
|
||||
classes = append(classes, DeviceLabel(g.Index)+" "+g.UUID+" "+g.Class())
|
||||
}
|
||||
want := []string{"2/mig0 MIG-aaa h100-80g-mig-3g.40gb", "2/mig1 MIG-bbb h100-80g-mig-3g.40gb",
|
||||
"2/mig4 MIG-ccc h100-80g-mig-1g.10gb"}
|
||||
if !slices.Equal(classes, want) {
|
||||
t.Errorf("devices %q, want %q", classes, want)
|
||||
}
|
||||
if g := gpus[1]; g.MemoryTotalMB != 40448 || g.MIG.GPUInstance != 1 || g.NUMANode != 1 ||
|
||||
g.Health.TemperatureC != 40 || len(g.NVLinkPeers) != 0 {
|
||||
t.Errorf("instance 1: %+v", g)
|
||||
}
|
||||
|
||||
// MIG on and nothing carved: the card, kept out of placement.
|
||||
gpus, isMIG = migFromNVML(card, fakeMIGCard{mode: true, supported: true, max: 7})
|
||||
if !isMIG || len(gpus) != 1 || gpus[0].IsMIG() || gpus[0].Health.OK() {
|
||||
t.Errorf("an empty MIG card: %+v", gpus)
|
||||
}
|
||||
// MIG off, or a card without it: the card, as it always was.
|
||||
for _, d := range []fakeMIGCard{{supported: true, max: 7}, {}} {
|
||||
gpus, isMIG = migFromNVML(card, d)
|
||||
if isMIG || len(gpus) != 1 || !reflect.DeepEqual(gpus[0], card) {
|
||||
t.Errorf("a card not in MIG mode came back as %+v", gpus)
|
||||
}
|
||||
}
|
||||
}
|
||||
|
||||
func TestMIGInstanceTablesAreRead(t *testing.T) {
|
||||
gis := ParseMIGInstances(migLGI)
|
||||
if len(gis) != 2 || gis[0] != (MIGInstance{GPU: 0, Profile: "3g.40gb", ProfileID: 9, GPUInstance: 1,
|
||||
ComputeInstance: -1, Placement: "4:4"}) {
|
||||
t.Errorf("-lgi: %+v", gis)
|
||||
}
|
||||
cis := ParseMIGInstances(migLCI)
|
||||
if len(cis) != 2 || cis[1] != (MIGInstance{GPU: 0, GPUInstance: 2, Profile: "3g.40gb", ProfileID: 2,
|
||||
ComputeInstance: 0, Placement: "0:3"}) {
|
||||
t.Errorf("-lci: %+v", cis)
|
||||
}
|
||||
if got := ParseMIGInstances("No GPU instances found: Not Found\n"); len(got) != 0 {
|
||||
t.Errorf("nothing to list read as %+v", got)
|
||||
}
|
||||
|
||||
cards, err := buildMIGCards([]byte(migReport), migList, migLGI, migLCI)
|
||||
if err != nil {
|
||||
t.Fatal(err)
|
||||
}
|
||||
if len(cards) != 2 || !cards[0].Enabled || len(cards[0].Instances) != 2 || len(cards[0].GPUInstances) != 2 ||
|
||||
len(cards[0].ComputeInstances) != 2 || cards[1].Enabled {
|
||||
t.Errorf("cards: %+v", cards)
|
||||
}
|
||||
}
|
||||
@@ -166,19 +166,25 @@ func splitTabs(l string) []string {
|
||||
|
||||
// Apply puts the topology on the GPUs it describes. What a GPU already knows
|
||||
// — NVLink peers from NVML, which is the more exact source — is kept.
|
||||
//
|
||||
// The matrix is of whole cards. A MIG instance takes its card's NUMA node and
|
||||
// adapters, and none of its NVLink: instances cannot reach each other or any
|
||||
// other card over it, and peers listed for one would draw a tensor-parallel
|
||||
// group onto it.
|
||||
func (t Topology) Apply(gpus []GPU) {
|
||||
for i := range gpus {
|
||||
g := &gpus[i]
|
||||
if len(g.NVLinkPeers) == 0 {
|
||||
for peer := range t.NVLink[g.Index] {
|
||||
card := g.CardIndex()
|
||||
if len(g.NVLinkPeers) == 0 && !g.IsMIG() {
|
||||
for peer := range t.NVLink[card] {
|
||||
g.NVLinkPeers = append(g.NVLinkPeers, peer)
|
||||
}
|
||||
sort.Ints(g.NVLinkPeers)
|
||||
}
|
||||
if n, ok := t.NUMA[g.Index]; ok {
|
||||
if n, ok := t.NUMA[card]; ok {
|
||||
g.NUMANode = n
|
||||
}
|
||||
if paths := t.NICPath[g.Index]; len(paths) > 0 {
|
||||
if paths := t.NICPath[card]; len(paths) > 0 {
|
||||
g.NICPaths = paths
|
||||
}
|
||||
}
|
||||
|
||||
@@ -62,6 +62,12 @@ type ShardSpec struct {
|
||||
|
||||
// GPUIndices are the local GPUs this shard uses.
|
||||
GPUIndices []int
|
||||
// GPUUUIDs name the same devices by UUID, in the same order, and are set
|
||||
// by the agent only when one of them is a MIG instance. An instance has
|
||||
// no index CUDA knows: CUDA_VISIBLE_DEVICES=MIG-<uuid> is the only way to
|
||||
// give a process one, and the indices placement uses for it (1000 and
|
||||
// up) mean nothing to CUDA.
|
||||
GPUUUIDs []string `json:"gpu_uuids,omitempty"`
|
||||
// HCAs are the adapters of the chosen fabric, and only that fabric. A shard
|
||||
// must never be given HCAs from two fabrics.
|
||||
HCAs []string
|
||||
@@ -257,7 +263,7 @@ func NCCLEnv(s ShardSpec) map[string]string { return baseEnv(s) }
|
||||
// one instead of timing out.
|
||||
func baseEnv(s ShardSpec) map[string]string {
|
||||
env := map[string]string{
|
||||
"CUDA_VISIBLE_DEVICES": joinInts(s.GPUIndices),
|
||||
"CUDA_VISIBLE_DEVICES": visibleDevices(s),
|
||||
// The indices above are nvidia-smi's, which counts by PCI bus. CUDA
|
||||
// counts fastest first unless told otherwise, and on a node with two
|
||||
// kinds of GPU the shard would get a different card than placement
|
||||
@@ -329,6 +335,21 @@ func materializeEnv(generated map[string]string) []string {
|
||||
return out
|
||||
}
|
||||
|
||||
// visibleDevices is CUDA_VISIBLE_DEVICES for a shard: the indices placement
|
||||
// gave it, or their UUIDs when the agent named them, which it does for a MIG
|
||||
// instance.
|
||||
func visibleDevices(s ShardSpec) string {
|
||||
if len(s.GPUUUIDs) > 0 {
|
||||
return strings.Join(s.GPUUUIDs, ",")
|
||||
}
|
||||
return joinInts(s.GPUIndices)
|
||||
}
|
||||
|
||||
// OnMIG reports whether the shard was given a MIG instance.
|
||||
func (s ShardSpec) OnMIG() bool {
|
||||
return slices.ContainsFunc(s.GPUUUIDs, func(u string) bool { return strings.HasPrefix(u, "MIG-") })
|
||||
}
|
||||
|
||||
func joinInts(v []int) string {
|
||||
parts := make([]string, len(v))
|
||||
for i, n := range v {
|
||||
|
||||
@@ -178,7 +178,11 @@ func (l *LlamaCpp) Commands(s ShardSpec) ([]Command, error) {
|
||||
// as the driver lists them, which on NVIDIA follows the same bus order
|
||||
// as nvidia-smi; were it not to, the shard would not hold memory on its
|
||||
// own GPUs, and starting it checks exactly that.
|
||||
if len(s.GPUIndices) > 0 {
|
||||
//
|
||||
// Not on a MIG instance, which Vulkan does not see at all: only CUDA
|
||||
// opens one, by the UUID CUDA_VISIBLE_DEVICES carries, and an index here
|
||||
// would name some other card.
|
||||
if len(s.GPUIndices) > 0 && !s.OnMIG() {
|
||||
env["GGML_VK_VISIBLE_DEVICES"] = joinInts(s.GPUIndices)
|
||||
}
|
||||
return []Command{{
|
||||
|
||||
@@ -0,0 +1,49 @@
|
||||
package engines
|
||||
|
||||
import "testing"
|
||||
|
||||
const migUUID = "MIG-c6d4f1ef-42e4-5de3-91c7-45d71c87eb3f"
|
||||
|
||||
func TestAShardOnAMIGInstanceIsGivenItByUUID(t *testing.T) {
|
||||
// Placement numbers card 0's instance 1 as 1001, which CUDA has never
|
||||
// heard of: CUDA_VISIBLE_DEVICES=1001 is no device at all, and =1 would
|
||||
// be the wrong card.
|
||||
s := singleNodeSpec()
|
||||
s.GPUIndices, s.GPUUUIDs = []int{1001}, []string{migUUID}
|
||||
s.Profile.TP = 1
|
||||
|
||||
env := envMap(buildOne(t, &VLLM{}, s).Env)
|
||||
if env["CUDA_VISIBLE_DEVICES"] != migUUID {
|
||||
t.Errorf("vLLM: CUDA_VISIBLE_DEVICES=%q, want the instance's UUID", env["CUDA_VISIBLE_DEVICES"])
|
||||
}
|
||||
|
||||
l := llamaSpec([]int{1001})
|
||||
l.GPUUUIDs = s.GPUUUIDs
|
||||
cmds, err := (&LlamaCpp{}).Commands(l)
|
||||
if err != nil {
|
||||
t.Fatal(err)
|
||||
}
|
||||
env = envMap(cmds[0].Env)
|
||||
if env["CUDA_VISIBLE_DEVICES"] != migUUID {
|
||||
t.Errorf("llama.cpp: CUDA_VISIBLE_DEVICES=%q, want the instance's UUID", env["CUDA_VISIBLE_DEVICES"])
|
||||
}
|
||||
// Vulkan does not see MIG instances, and an index for it would name
|
||||
// some other card.
|
||||
if v, set := env["GGML_VK_VISIBLE_DEVICES"]; set {
|
||||
t.Errorf("GGML_VK_VISIBLE_DEVICES=%q on a MIG instance", v)
|
||||
}
|
||||
if v, _ := flagValue(cmds[0].Args, "--n-gpu-layers"); v != "999" {
|
||||
t.Errorf("the model was not offloaded to the instance: --n-gpu-layers %q", v)
|
||||
}
|
||||
}
|
||||
|
||||
func TestAShardOnWholeCardsIsStillGivenThemByIndex(t *testing.T) {
|
||||
env := envMap(buildOne(t, &VLLM{}, singleNodeSpec()).Env)
|
||||
if env["CUDA_VISIBLE_DEVICES"] != "0,1,2,3" {
|
||||
t.Errorf("CUDA_VISIBLE_DEVICES=%q", env["CUDA_VISIBLE_DEVICES"])
|
||||
}
|
||||
cmds, _ := (&LlamaCpp{}).Commands(llamaSpec([]int{2}))
|
||||
if env := envMap(cmds[0].Env); env["GGML_VK_VISIBLE_DEVICES"] != "2" {
|
||||
t.Errorf("GGML_VK_VISIBLE_DEVICES=%q", env["GGML_VK_VISIBLE_DEVICES"])
|
||||
}
|
||||
}
|
||||
@@ -0,0 +1,40 @@
|
||||
package agent
|
||||
|
||||
import (
|
||||
"testing"
|
||||
|
||||
"gitea.mynodes.xyz/ilker/llmgw/internal/agent/discovery"
|
||||
"gitea.mynodes.xyz/ilker/llmgw/internal/agent/engines"
|
||||
)
|
||||
|
||||
func TestAShardPlacedOnAMIGInstanceIsLaunchedWithItsUUID(t *testing.T) {
|
||||
// The control plane sends device 1001: card 0's instance 1, by the number
|
||||
// placement gives it. Only this node knows the instance's UUID, which is
|
||||
// the one thing CUDA will open it by.
|
||||
a := &Agent{}
|
||||
a.inv.GPUs = []discovery.GPU{
|
||||
{Index: 1000, UUID: "MIG-aaa", MIG: &discovery.MIGDevice{ParentIndex: 0, Device: 0, Profile: "3g.40gb"}},
|
||||
{Index: 1001, UUID: "MIG-bbb", MIG: &discovery.MIGDevice{ParentIndex: 0, Device: 1, Profile: "3g.40gb"}},
|
||||
{Index: 1, UUID: "GPU-whole"},
|
||||
}
|
||||
|
||||
spec := engines.ShardSpec{GPUIndices: []int{1001}}
|
||||
a.localizeSpec(&spec)
|
||||
if got := engines.NCCLEnv(spec)["CUDA_VISIBLE_DEVICES"]; got != "MIG-bbb" {
|
||||
t.Errorf("CUDA_VISIBLE_DEVICES=%q, want MIG-bbb", got)
|
||||
}
|
||||
|
||||
// A whole card is given by index, as it always was.
|
||||
whole := engines.ShardSpec{GPUIndices: []int{1}}
|
||||
a.localizeSpec(&whole)
|
||||
if whole.GPUUUIDs != nil || engines.NCCLEnv(whole)["CUDA_VISIBLE_DEVICES"] != "1" {
|
||||
t.Errorf("a whole card was given as %v / %q", whole.GPUUUIDs, engines.NCCLEnv(whole)["CUDA_VISIBLE_DEVICES"])
|
||||
}
|
||||
|
||||
// A device this node does not have is not guessed at.
|
||||
gone := engines.ShardSpec{GPUIndices: []int{1002}}
|
||||
a.localizeSpec(&gone)
|
||||
if gone.GPUUUIDs != nil {
|
||||
t.Errorf("an unknown device was named %v", gone.GPUUUIDs)
|
||||
}
|
||||
}
|
||||
@@ -159,13 +159,13 @@ func printInventory(inv discovery.Inventory) {
|
||||
if !g.Health.OK() {
|
||||
health = g.Health.Problems[0]
|
||||
}
|
||||
fmt.Fprintf(w, " %d\t%s\t%s\t%d MiB\t%s\t%s\n",
|
||||
g.Index, g.Class(), g.Name, g.MemoryTotalMB, g.ComputeCapability, health)
|
||||
fmt.Fprintf(w, " %s\t%s\t%s\t%d MiB\t%s\t%s\n",
|
||||
discovery.DeviceLabel(g.Index), g.Class(), g.Name, g.MemoryTotalMB, g.ComputeCapability, health)
|
||||
}
|
||||
fmt.Fprintf(w, " classes: %v\n", inv.Classes())
|
||||
for _, g := range inv.GPUs {
|
||||
if len(g.NVLinkPeers) > 0 {
|
||||
fmt.Fprintf(w, " GPU %d NVLink peers: %v\n", g.Index, g.NVLinkPeers)
|
||||
fmt.Fprintf(w, " GPU %s NVLink peers: %v\n", discovery.DeviceLabel(g.Index), g.NVLinkPeers)
|
||||
}
|
||||
}
|
||||
}
|
||||
|
||||
+24
-2
@@ -14,6 +14,7 @@ import (
|
||||
|
||||
"github.com/spf13/cobra"
|
||||
|
||||
"gitea.mynodes.xyz/ilker/llmgw/internal/agent/discovery"
|
||||
"gitea.mynodes.xyz/ilker/llmgw/internal/control/adminapi"
|
||||
)
|
||||
|
||||
@@ -212,7 +213,7 @@ func newNodesCmd(client func() *ctlClient, asJSON *bool) *cobra.Command {
|
||||
// at when a model will not place and the hardware looks
|
||||
// fine.
|
||||
join(n.Engines),
|
||||
join(n.Classes), join(n.Fabrics), n.Replicas, n.LastSeenAgo)
|
||||
classesColumn(n), join(n.Fabrics), n.Replicas, n.LastSeenAgo)
|
||||
}
|
||||
_ = w.Flush()
|
||||
|
||||
@@ -410,7 +411,9 @@ func newReplicasCmd(client func() *ctlClient, asJSON *bool) *cobra.Command {
|
||||
for _, r := range reps {
|
||||
var nodes []string
|
||||
for _, s := range r.Shards {
|
||||
nodes = append(nodes, fmt.Sprintf("%s:%v", s.Node, s.GPUs))
|
||||
// "[0/mig2]" for a MIG instance, not the 1002 it is
|
||||
// numbered by.
|
||||
nodes = append(nodes, fmt.Sprintf("%s:%v", s.Node, discovery.DeviceLabels(s.GPUs)))
|
||||
}
|
||||
// The state says stale rather than a column of its own: most
|
||||
// replicas are not, a column would be empty for all of them,
|
||||
@@ -540,6 +543,25 @@ func emitJSON(v any) error {
|
||||
return enc.Encode(v)
|
||||
}
|
||||
|
||||
// classesColumn is a node's GPU classes, with how many of each when it has
|
||||
// more than one or MIG instances among them: a card cut into two 3g.40gb
|
||||
// instances beside a whole card is "a100-80g-mig-3g.40gb×2,a100-80g×1", where
|
||||
// the GPUS column's 3 alone would read as three of something.
|
||||
func classesColumn(n adminapi.NodeView) string {
|
||||
counted := len(n.ClassGPUs) > 1
|
||||
for _, c := range n.ClassGPUs {
|
||||
counted = counted || c.MIG
|
||||
}
|
||||
if !counted {
|
||||
return join(n.Classes)
|
||||
}
|
||||
parts := make([]string, len(n.ClassGPUs))
|
||||
for i, c := range n.ClassGPUs {
|
||||
parts[i] = fmt.Sprintf("%s×%d", c.Class, c.Total)
|
||||
}
|
||||
return strings.Join(parts, ",")
|
||||
}
|
||||
|
||||
func join(v []string) string {
|
||||
if len(v) == 0 {
|
||||
return "-"
|
||||
|
||||
@@ -110,9 +110,10 @@ func printDoctor(out io.Writer, f doctor.Facts, findings []doctor.Finding, verbo
|
||||
|
||||
w := tabwriter.NewWriter(out, 0, 0, 2, ' ', 0)
|
||||
if len(f.GPUs) > 0 {
|
||||
fmt.Fprintln(w, "\nGPU\tNAME\tNUMA\tNVLINK PEERS\tNEAREST ADAPTER")
|
||||
fmt.Fprintln(w, "\nGPU\tNAME\tCLASS\tNUMA\tNVLINK PEERS\tNEAREST ADAPTER")
|
||||
for _, g := range f.GPUs {
|
||||
fmt.Fprintf(w, "%d\t%s\t%d\t%s\t%s\n", g.Index, g.Name, g.NUMANode,
|
||||
// A MIG instance as 0/mig2, under its card.
|
||||
fmt.Fprintf(w, "%s\t%s\t%s\t%d\t%s\t%s\n", discovery.DeviceLabel(g.Index), g.Name, g.Class(), g.NUMANode,
|
||||
orDash(ints(g.NVLinkPeers)), orDash(nearest(g.NICPaths)))
|
||||
}
|
||||
}
|
||||
|
||||
@@ -0,0 +1,40 @@
|
||||
package cli
|
||||
|
||||
import (
|
||||
"testing"
|
||||
|
||||
"gitea.mynodes.xyz/ilker/llmgw/internal/control/adminapi"
|
||||
"gitea.mynodes.xyz/ilker/llmgw/internal/modelplan"
|
||||
)
|
||||
|
||||
func TestAPlanSeesANodesMIGInstancesAsAClassOfTheirOwn(t *testing.T) {
|
||||
// Card 0 cut into two 3g.40gb instances, both free, and card 1 whole and
|
||||
// busy: the instances are a pool of forty-gigabyte devices, and the busy
|
||||
// card no pool at all.
|
||||
hw := hardwareFrom([]adminapi.NodeView{{ID: "a100", State: "ready", GPUTotal: 3, GPUFree: 2,
|
||||
Classes: []string{"a100-80g-mig-3g.40gb", "a100-80g"},
|
||||
ClassGPUs: []adminapi.ClassGPUs{
|
||||
{Class: "a100-80g-mig-3g.40gb", Total: 2, Free: 2, MIG: true},
|
||||
{Class: "a100-80g", Total: 1, Free: 0},
|
||||
}}})
|
||||
if len(hw) != 1 {
|
||||
t.Fatalf("pools: %+v", hw)
|
||||
}
|
||||
want := modelplan.Hardware{Class: "a100-80g-mig-3g.40gb", GPUMemGB: 40, GPUsPerNode: 2, Nodes: 1}
|
||||
if hw[0] != want {
|
||||
t.Errorf("pool %+v, want %+v", hw[0], want)
|
||||
}
|
||||
}
|
||||
|
||||
func TestCtlNodesCountsANodesDevicesByClassWhenItHasMIG(t *testing.T) {
|
||||
mig := adminapi.NodeView{Classes: []string{"a100-80g-mig-3g.40gb", "a100-80g"}, ClassGPUs: []adminapi.ClassGPUs{
|
||||
{Class: "a100-80g-mig-3g.40gb", Total: 2, MIG: true}, {Class: "a100-80g", Total: 1}}}
|
||||
if got := classesColumn(mig); got != "a100-80g-mig-3g.40gb×2,a100-80g×1" {
|
||||
t.Errorf("MIG node: %q", got)
|
||||
}
|
||||
// A node of one kind of whole card reads as it always did.
|
||||
plain := adminapi.NodeView{Classes: []string{"h100-80g"}, ClassGPUs: []adminapi.ClassGPUs{{Class: "h100-80g", Total: 8}}}
|
||||
if got := classesColumn(plain); got != "h100-80g" {
|
||||
t.Errorf("plain node: %q", got)
|
||||
}
|
||||
}
|
||||
+35
-32
@@ -155,28 +155,41 @@ func hardwareFrom(nodes []adminapi.NodeView) []modelplan.Hardware {
|
||||
if len(n.Fabrics) > 0 {
|
||||
fabric = n.Fabrics[0]
|
||||
}
|
||||
class := ""
|
||||
if len(n.Classes) > 0 {
|
||||
class = n.Classes[0]
|
||||
// Each class of the node's devices is a pool of its own: a node with
|
||||
// a card in MIG mode has its instances' classes, and any whole card's
|
||||
// beside them. A node that does not count by class is its first
|
||||
// class, as it always was.
|
||||
kinds := n.ClassGPUs
|
||||
if len(kinds) == 0 {
|
||||
class := ""
|
||||
if len(n.Classes) > 0 {
|
||||
class = n.Classes[0]
|
||||
}
|
||||
kinds = []adminapi.ClassGPUs{{Class: class, Total: n.GPUTotal, Free: n.GPUFree}}
|
||||
}
|
||||
k := key{class, fabric}
|
||||
if pools[k] == nil {
|
||||
pools[k] = &modelplan.Hardware{Class: class, Fabric: fabric}
|
||||
}
|
||||
p := pools[k]
|
||||
p.Nodes++
|
||||
// The widest a single node could contribute, not the total: a tensor
|
||||
// group takes the same number of cards from every node it spans.
|
||||
if n.GPUFree > p.GPUsPerNode {
|
||||
p.GPUsPerNode = n.GPUFree
|
||||
}
|
||||
if n.MemoryGB > p.HostMemGB {
|
||||
p.HostMemGB = n.MemoryGB
|
||||
}
|
||||
// Card memory from the class label, which carries it by construction:
|
||||
// "h100-80g" is eighty gigabytes and says so.
|
||||
if class != "" && p.GPUMemGB == 0 {
|
||||
p.GPUMemGB = memFromClass(class)
|
||||
for _, kind := range kinds {
|
||||
class := kind.Class
|
||||
k := key{class, fabric}
|
||||
if pools[k] == nil {
|
||||
pools[k] = &modelplan.Hardware{Class: class, Fabric: fabric}
|
||||
}
|
||||
p := pools[k]
|
||||
p.Nodes++
|
||||
// The widest a single node could contribute, not the total: a
|
||||
// tensor group takes the same number of cards from every node it
|
||||
// spans.
|
||||
if kind.Free > p.GPUsPerNode {
|
||||
p.GPUsPerNode = kind.Free
|
||||
}
|
||||
if n.MemoryGB > p.HostMemGB {
|
||||
p.HostMemGB = n.MemoryGB
|
||||
}
|
||||
// Card memory from the class label, which carries it by
|
||||
// construction: "h100-80g" is eighty gigabytes and says so, and
|
||||
// "a100-80g-mig-3g.40gb" is an instance of forty.
|
||||
if class != "" && p.GPUMemGB == 0 {
|
||||
p.GPUMemGB = memFromClass(class)
|
||||
}
|
||||
}
|
||||
}
|
||||
|
||||
@@ -191,17 +204,7 @@ func hardwareFrom(nodes []adminapi.NodeView) []modelplan.Hardware {
|
||||
}
|
||||
|
||||
// memFromClass reads the card size out of a class label such as "h100-80g".
|
||||
func memFromClass(class string) int {
|
||||
i := strings.LastIndex(class, "-")
|
||||
if i < 0 || !strings.HasSuffix(class, "g") {
|
||||
return 0
|
||||
}
|
||||
var gb int
|
||||
if _, err := fmt.Sscanf(class[i+1:], "%dg", &gb); err != nil {
|
||||
return 0
|
||||
}
|
||||
return gb
|
||||
}
|
||||
func memFromClass(class string) int { return modelplan.MemFromClass(class) }
|
||||
|
||||
// catalogEntry renders a fit as the YAML that would serve it.
|
||||
func catalogEntry(m modelplan.Model, f modelplan.Fit, source string, context int) string {
|
||||
|
||||
@@ -17,6 +17,7 @@ import (
|
||||
"github.com/charmbracelet/lipgloss"
|
||||
"github.com/spf13/cobra"
|
||||
|
||||
"gitea.mynodes.xyz/ilker/llmgw/internal/agent/discovery"
|
||||
"gitea.mynodes.xyz/ilker/llmgw/internal/config"
|
||||
"gitea.mynodes.xyz/ilker/llmgw/internal/control/adminapi"
|
||||
"gitea.mynodes.xyz/ilker/llmgw/internal/control/catalog"
|
||||
@@ -1080,7 +1081,7 @@ func (m consoleModel) panel() (title, body, keys string) {
|
||||
for _, r := range m.data.replicas {
|
||||
var nodes []string
|
||||
for _, s := range r.Shards {
|
||||
nodes = append(nodes, fmt.Sprintf("%s%v", s.Node, s.GPUs))
|
||||
nodes = append(nodes, fmt.Sprintf("%s%v", s.Node, discovery.DeviceLabels(s.GPUs)))
|
||||
}
|
||||
rows = append(rows, []string{r.ID, r.Model, r.State, r.Pool, strings.Join(nodes, " "),
|
||||
(time.Duration(r.AgeSec) * time.Second).Round(time.Second).String()})
|
||||
@@ -1224,14 +1225,31 @@ func (m consoleModel) gpuRows() [][]string {
|
||||
for _, n := range m.data.nodes {
|
||||
for _, g := range n.GPUs {
|
||||
busy, mem, temp, power := "—", "—", "—", "—"
|
||||
// A MIG instance under its card: its own memory, the card's heat
|
||||
// and power, and no utilisation, which no driver measures per
|
||||
// instance — said, rather than shown as the card's or as zero.
|
||||
mig := g.MIGProfile != ""
|
||||
if mig {
|
||||
busy = sDim.Render("n/a on MIG")
|
||||
if g.MemoryTotalMB > 0 {
|
||||
mem = fmt.Sprintf("%.1f/%.0f GB", float64(g.MemoryUsedMB)/1024, float64(g.MemoryTotalMB)/1024)
|
||||
}
|
||||
}
|
||||
card := g.Card
|
||||
if g.Label == "" {
|
||||
// A control plane older than MIG, which sends no card.
|
||||
card = g.Index
|
||||
}
|
||||
if n.Load != nil {
|
||||
for _, s := range n.Load.GPUs {
|
||||
if s.Index != g.Index {
|
||||
if s.Index != card {
|
||||
continue
|
||||
}
|
||||
busy = fmt.Sprintf("%.0f%%", s.UtilPercent)
|
||||
if s.MemoryTotalMB > 0 {
|
||||
mem = fmt.Sprintf("%.1f/%.0f GB", s.MemoryUsedMB/1024, s.MemoryTotalMB/1024)
|
||||
if !mig {
|
||||
busy = fmt.Sprintf("%.0f%%", s.UtilPercent)
|
||||
if s.MemoryTotalMB > 0 {
|
||||
mem = fmt.Sprintf("%.1f/%.0f GB", s.MemoryUsedMB/1024, s.MemoryTotalMB/1024)
|
||||
}
|
||||
}
|
||||
if s.TempC > 0 {
|
||||
temp = fmt.Sprintf("%.0f°C", s.TempC)
|
||||
@@ -1245,7 +1263,12 @@ func (m consoleModel) gpuRows() [][]string {
|
||||
if holder == "" {
|
||||
holder = sDim.Render("free")
|
||||
}
|
||||
rows = append(rows, []string{n.ID, strconv.Itoa(g.Index), g.Name, busy, mem, temp, power, holder})
|
||||
label := g.Label
|
||||
if label == "" {
|
||||
// A control plane older than labels.
|
||||
label = strconv.Itoa(g.Index)
|
||||
}
|
||||
rows = append(rows, []string{n.ID, label, g.Name, busy, mem, temp, power, holder})
|
||||
}
|
||||
}
|
||||
return rows
|
||||
@@ -1266,6 +1289,15 @@ func (m consoleModel) nodeDetail(n adminapi.NodeView) string {
|
||||
}
|
||||
kv("disk", fmt.Sprintf("%d GB free of %d", n.DiskFreeGB, n.DiskTotalGB))
|
||||
kv("replicas", strconv.Itoa(n.Replicas))
|
||||
// By class, which on a node with a card in MIG mode is the instances'
|
||||
// profiles beside any whole card: what a profile's gpu_class can name.
|
||||
for _, c := range n.ClassGPUs {
|
||||
what := fmt.Sprintf("%d, %d free", c.Total, c.Free)
|
||||
if c.MIG {
|
||||
what += " · MIG instances, one to a replica"
|
||||
}
|
||||
kv(c.Class, what)
|
||||
}
|
||||
if len(n.Provision) > 0 {
|
||||
b.WriteString("\n " + lipgloss.NewStyle().Bold(true).Render("Engines") + "\n")
|
||||
for _, p := range n.Provision {
|
||||
|
||||
@@ -228,7 +228,12 @@ type NodeView struct {
|
||||
DiskFreeGB int `json:"disk_free_gb,omitempty"`
|
||||
DiskTotalGB int `json:"disk_total_gb,omitempty"`
|
||||
Classes []string `json:"gpu_classes,omitempty"`
|
||||
Fabrics []string `json:"fabrics,omitempty"`
|
||||
// ClassGPUs counts the node's devices by class, in the order of Classes.
|
||||
// A node with a card in MIG mode has several classes — each profile its
|
||||
// instances are cut to, and any whole card beside them — and GPUTotal
|
||||
// alone would add 3g.40gb instances to 80 GB cards.
|
||||
ClassGPUs []ClassGPUs `json:"gpus_by_class,omitempty"`
|
||||
Fabrics []string `json:"fabrics,omitempty"`
|
||||
|
||||
// Unhealthy lists GPUs kept out of placement and why, which is usually the
|
||||
// answer when a node looks idle but nothing will schedule onto it.
|
||||
@@ -255,10 +260,34 @@ type NodeView struct {
|
||||
IMEXChannels int `json:"imex_channels,omitempty"`
|
||||
}
|
||||
|
||||
// ClassGPUs is how many of a node's devices are of one class, and how many
|
||||
// of those are free or kept out of placement.
|
||||
type ClassGPUs struct {
|
||||
Class string `json:"class"`
|
||||
Total int `json:"total"`
|
||||
Free int `json:"free"`
|
||||
Unhealthy int `json:"unhealthy,omitempty"`
|
||||
// MIG marks a class of MIG instances, each of which takes a replica of
|
||||
// its own and never joins a tensor-parallel group.
|
||||
MIG bool `json:"mig,omitempty"`
|
||||
}
|
||||
|
||||
// GPUView is one card as a node's page shows it.
|
||||
type GPUView struct {
|
||||
Index int `json:"index"`
|
||||
Name string `json:"name"`
|
||||
// Label is the device as people are shown it: "3" for a whole card,
|
||||
// "0/mig2" for card 0's MIG instance 2.
|
||||
Label string `json:"label"`
|
||||
Class string `json:"class"`
|
||||
// Card is the physical card's index: the device's own, or for a MIG
|
||||
// instance its parent's, which is what the card's sensors are under.
|
||||
Card int `json:"card"`
|
||||
// MIGProfile is the instance's profile, like 3g.40gb; empty for a
|
||||
// whole card.
|
||||
MIGProfile string `json:"mig_profile,omitempty"`
|
||||
MemoryTotalMB int `json:"memory_total_mb,omitempty"`
|
||||
MemoryUsedMB int `json:"memory_used_mb,omitempty"`
|
||||
// ComputeCapability is what decides which engine builds run on the card:
|
||||
// CUDA 13 builds need 7.5, so a V100 (7.0) runs only older ones.
|
||||
ComputeCapability string `json:"compute_capability,omitempty"`
|
||||
@@ -556,15 +585,25 @@ func (a *API) Nodes() []NodeView {
|
||||
for _, w := range n.Weights {
|
||||
v.Models = append(v.Models, w.Path)
|
||||
}
|
||||
seen := map[string]struct{}{}
|
||||
seen := map[string]int{}
|
||||
free := inv.FreeGPUs(n.ID)
|
||||
for _, g := range n.GPUs {
|
||||
if _, dup := seen[g.Class()]; !dup {
|
||||
seen[g.Class()] = struct{}{}
|
||||
k, dup := seen[g.Class()]
|
||||
if !dup {
|
||||
k = len(v.ClassGPUs)
|
||||
seen[g.Class()] = k
|
||||
v.Classes = append(v.Classes, g.Class())
|
||||
v.ClassGPUs = append(v.ClassGPUs, ClassGPUs{Class: g.Class(), MIG: g.IsMIG()})
|
||||
}
|
||||
if !g.Health.OK() {
|
||||
c := &v.ClassGPUs[k]
|
||||
c.Total++
|
||||
switch {
|
||||
case !g.Health.OK():
|
||||
c.Unhealthy++
|
||||
v.Unhealthy = append(v.Unhealthy,
|
||||
fmt.Sprintf("gpu %d: %s", g.Index, g.Health.Problems[0]))
|
||||
fmt.Sprintf("gpu %s: %s", discovery.DeviceLabel(g.Index), g.Health.Problems[0]))
|
||||
case slices.Contains(free, g.Index):
|
||||
c.Free++
|
||||
}
|
||||
}
|
||||
if !n.LastSeen.IsZero() {
|
||||
@@ -574,7 +613,12 @@ func (a *API) Nodes() []NodeView {
|
||||
v.NVLinkDomain, v.IMEX, v.IMEXChannels = n.NVLinkDomain(), n.IMEX.State, n.IMEX.Channels
|
||||
for _, g := range n.GPUs {
|
||||
gv := GPUView{Index: g.Index, Name: g.Name, ComputeCapability: g.ComputeCapability,
|
||||
NUMA: g.NUMANode, NVLinkPeers: g.NVLinkPeers}
|
||||
NUMA: g.NUMANode, NVLinkPeers: g.NVLinkPeers,
|
||||
Label: discovery.DeviceLabel(g.Index), Class: g.Class(), Card: g.CardIndex(),
|
||||
MemoryTotalMB: g.MemoryTotalMB, MemoryUsedMB: g.MemoryUsedMB}
|
||||
if g.MIG != nil {
|
||||
gv.MIGProfile = g.MIG.Profile
|
||||
}
|
||||
for hca, rel := range g.NICPaths {
|
||||
if gv.NearestNIC == "" || discovery.PathRank(rel) < discovery.PathRank(gv.NICPath) ||
|
||||
(discovery.PathRank(rel) == discovery.PathRank(gv.NICPath) && hca < gv.NearestNIC) {
|
||||
@@ -1617,6 +1661,13 @@ func (a *API) PoolNodes() []modelplan.PoolNode {
|
||||
p.Class = n.Classes[0]
|
||||
p.GPUMemGB = modelplan.MemFromClass(p.Class)
|
||||
}
|
||||
// By class, with each class's own count of devices: a node with a
|
||||
// card in MIG mode is several, and its first class alone would
|
||||
// count every instance and card as that one.
|
||||
for _, c := range n.ClassGPUs {
|
||||
p.Kinds = append(p.Kinds, modelplan.PoolKind{Class: c.Class,
|
||||
GPUMemGB: modelplan.MemFromClass(c.Class), GPUs: c.Total, FreeGPUs: c.Free})
|
||||
}
|
||||
if len(n.Fabrics) > 0 {
|
||||
p.Fabric = n.Fabrics[0]
|
||||
}
|
||||
|
||||
@@ -0,0 +1,65 @@
|
||||
package adminapi
|
||||
|
||||
import (
|
||||
"reflect"
|
||||
"testing"
|
||||
|
||||
"gitea.mynodes.xyz/ilker/llmgw/internal/agent/discovery"
|
||||
"gitea.mynodes.xyz/ilker/llmgw/internal/control/inventory"
|
||||
)
|
||||
|
||||
// migNode has card 0 cut into two 3g.40gb instances and card 1 whole.
|
||||
func migNode(id string) inventory.Node {
|
||||
nd := inventory.Node{ID: id, State: inventory.Ready, AgentVersion: "v1", MemoryTotalMB: 512 * 1024}
|
||||
for dev := range 2 {
|
||||
nd.GPUs = append(nd.GPUs, discovery.GPU{
|
||||
Index: discovery.MIGIndex(0, dev), Name: "NVIDIA A100-SXM4-80GB MIG 3g.40gb", UUID: "MIG-x",
|
||||
MemoryTotalMB: 40192, MemoryUsedMB: 37,
|
||||
MIG: &discovery.MIGDevice{ParentIndex: 0, ParentMemoryTotalMB: 81920, Device: dev, Profile: "3g.40gb"},
|
||||
})
|
||||
}
|
||||
nd.GPUs = append(nd.GPUs, discovery.GPU{Index: 1, Name: "NVIDIA A100-SXM4-80GB", MemoryTotalMB: 81920})
|
||||
return nd
|
||||
}
|
||||
|
||||
func TestANodeWithACardInMIGModeCountsItsDevicesByClass(t *testing.T) {
|
||||
a, ctl := setup(t, testModels(), migNode("a100"))
|
||||
ctl.Inventory().Allocate("a100", inventory.Allocation{ShardID: "s", ReplicaID: "r", GPUIndices: []int{1000}})
|
||||
|
||||
n := a.Nodes()[0]
|
||||
want := []ClassGPUs{
|
||||
{Class: "a100-80g-mig-3g.40gb", Total: 2, Free: 1, MIG: true},
|
||||
{Class: "a100-80g", Total: 1, Free: 1},
|
||||
}
|
||||
if !reflect.DeepEqual(n.ClassGPUs, want) {
|
||||
t.Errorf("by class: %+v\nwant %+v", n.ClassGPUs, want)
|
||||
}
|
||||
// Each device as people are shown it: the instance under its card, with
|
||||
// its own memory, and the card its sensors are read under.
|
||||
g := n.GPUs[1]
|
||||
if g.Label != "0/mig1" || g.Card != 0 || g.MIGProfile != "3g.40gb" || g.MemoryTotalMB != 40192 ||
|
||||
g.Class != "a100-80g-mig-3g.40gb" {
|
||||
t.Errorf("instance view: %+v", g)
|
||||
}
|
||||
if w := n.GPUs[2]; w.Label != "1" || w.Card != 1 || w.MIGProfile != "" {
|
||||
t.Errorf("whole card view: %+v", w)
|
||||
}
|
||||
|
||||
// The fleet summary attributes each device to its own class, where it
|
||||
// once put every card of a node under the node's only class.
|
||||
s := a.Summary()
|
||||
got := map[string][2]int{}
|
||||
for _, c := range s.GPUs {
|
||||
got[c.Class] = [2]int{c.Total, c.Used}
|
||||
}
|
||||
if !reflect.DeepEqual(got, map[string][2]int{"a100-80g-mig-3g.40gb": {2, 1}, "a100-80g": {1, 0}}) {
|
||||
t.Errorf("summary by class: %v", got)
|
||||
}
|
||||
|
||||
// And a plan sees both classes, each with its own count.
|
||||
pool := a.PoolNodes()
|
||||
if len(pool) != 1 || len(pool[0].Kinds) != 2 || pool[0].Kinds[0].GPUMemGB != 40 ||
|
||||
pool[0].Kinds[0].FreeGPUs != 1 || pool[0].Kinds[1].GPUMemGB != 80 {
|
||||
t.Errorf("pool: %+v", pool)
|
||||
}
|
||||
}
|
||||
@@ -148,12 +148,14 @@ func (a *API) Summary() Summary {
|
||||
byClass[c] = &ClassUse{Class: c}
|
||||
}
|
||||
}
|
||||
// A node reports one class in practice; attribute its cards to it.
|
||||
if len(n.Classes) == 1 {
|
||||
u := byClass[n.Classes[0]]
|
||||
u.Total += n.GPUTotal
|
||||
u.Unhealthy += len(n.Unhealthy)
|
||||
u.Used += n.GPUTotal - n.GPUFree - len(n.Unhealthy)
|
||||
// Each class its own devices, which a node with a card in MIG mode
|
||||
// needs: its instances are one class or several, and any whole card
|
||||
// beside them another.
|
||||
for _, c := range n.ClassGPUs {
|
||||
u := byClass[c.Class]
|
||||
u.Total += c.Total
|
||||
u.Unhealthy += c.Unhealthy
|
||||
u.Used += c.Total - c.Free - c.Unhealthy
|
||||
}
|
||||
}
|
||||
for _, u := range byClass {
|
||||
|
||||
@@ -71,6 +71,7 @@ func NodeFromRegister(r *llmgwv1.Register) inventory.Node {
|
||||
TemperatureC: int(g.GetTemperatureC()),
|
||||
Problems: g.GetProblems(),
|
||||
},
|
||||
MIG: migFrom(g.GetMig()),
|
||||
})
|
||||
}
|
||||
n.IMEX = discovery.IMEX{State: r.GetImex().GetState(), Channels: int(r.GetImex().GetChannels())}
|
||||
@@ -131,6 +132,13 @@ func RegisterFromInventory(nodeID, hostname, mgmtAddr, agentVersion string,
|
||||
last.FabricState, last.FabricStatus, last.ClusterUuid = f.State, f.Status, f.ClusterUUID
|
||||
last.CliqueId, last.FabricBandwidth = f.CliqueID, f.Bandwidth
|
||||
}
|
||||
if m := g.MIG; m != nil {
|
||||
r.Gpus[len(r.Gpus)-1].Mig = &llmgwv1.MIGDevice{
|
||||
ParentIndex: int32(m.ParentIndex), ParentUuid: m.ParentUUID,
|
||||
ParentMemoryTotalMb: int32(m.ParentMemoryTotalMB), Device: int32(m.Device),
|
||||
Profile: m.Profile, GpuInstance: int32(m.GPUInstance), ComputeInstance: int32(m.ComputeInstance),
|
||||
}
|
||||
}
|
||||
}
|
||||
r.Imex = &llmgwv1.IMEX{State: inv.IMEX.State, Channels: int32(inv.IMEX.Channels)}
|
||||
for _, f := range fabrics {
|
||||
@@ -286,6 +294,19 @@ func int32Slice(v []int) []int32 {
|
||||
return out
|
||||
}
|
||||
|
||||
// migFrom is a MIG instance's parentage as the wire carries it, nil for a
|
||||
// whole card and from every agent older than MIG support.
|
||||
func migFrom(m *llmgwv1.MIGDevice) *discovery.MIGDevice {
|
||||
if m == nil {
|
||||
return nil
|
||||
}
|
||||
return &discovery.MIGDevice{
|
||||
ParentIndex: int(m.GetParentIndex()), ParentUUID: m.GetParentUuid(),
|
||||
ParentMemoryTotalMB: int(m.GetParentMemoryTotalMb()), Device: int(m.GetDevice()),
|
||||
Profile: m.GetProfile(), GPUInstance: int(m.GetGpuInstance()), ComputeInstance: int(m.GetComputeInstance()),
|
||||
}
|
||||
}
|
||||
|
||||
// fabricFrom is a GPU's NVLink fabric as the wire carries it, nil when the
|
||||
// driver reported none.
|
||||
func fabricFrom(state, status, cluster, clique, bandwidth string) *discovery.GPUFabric {
|
||||
|
||||
@@ -0,0 +1,27 @@
|
||||
package agentsvc
|
||||
|
||||
import (
|
||||
"reflect"
|
||||
"testing"
|
||||
|
||||
"gitea.mynodes.xyz/ilker/llmgw/internal/agent/discovery"
|
||||
)
|
||||
|
||||
func TestAMIGInstanceKeepsItsParentageOnTheWire(t *testing.T) {
|
||||
inst := discovery.GPU{Index: 1001, UUID: "MIG-bbb", Name: "NVIDIA A100-SXM4-80GB MIG 3g.40gb", MemoryTotalMB: 40192,
|
||||
MIG: &discovery.MIGDevice{ParentIndex: 0, ParentUUID: "GPU-card", ParentMemoryTotalMB: 81920,
|
||||
Device: 1, Profile: "3g.40gb", GPUInstance: 1, ComputeInstance: 0}}
|
||||
whole := discovery.GPU{Index: 1, UUID: "GPU-whole", Name: "NVIDIA A100-SXM4-80GB", MemoryTotalMB: 81920}
|
||||
|
||||
reg := RegisterFromInventory("n1", "h", "10.0.0.1", "v", nil, discovery.Inventory{GPUs: []discovery.GPU{inst, whole}}, nil)
|
||||
n := NodeFromRegister(reg)
|
||||
if len(n.GPUs) != 2 {
|
||||
t.Fatalf("got %d GPUs", len(n.GPUs))
|
||||
}
|
||||
if !reflect.DeepEqual(n.GPUs[0].MIG, inst.MIG) || n.GPUs[0].Class() != "a100-80g-mig-3g.40gb" {
|
||||
t.Errorf("the instance arrived as %s %+v", n.GPUs[0].Class(), n.GPUs[0].MIG)
|
||||
}
|
||||
if n.GPUs[1].MIG != nil || n.GPUs[1].Class() != "a100-80g" {
|
||||
t.Errorf("the whole card arrived as %s %+v", n.GPUs[1].Class(), n.GPUs[1].MIG)
|
||||
}
|
||||
}
|
||||
@@ -12,6 +12,7 @@ import (
|
||||
"strings"
|
||||
"time"
|
||||
|
||||
"gitea.mynodes.xyz/ilker/llmgw/internal/agent/discovery"
|
||||
"gitea.mynodes.xyz/ilker/llmgw/internal/agent/engines"
|
||||
"gitea.mynodes.xyz/ilker/llmgw/internal/control/placement"
|
||||
)
|
||||
@@ -701,6 +702,17 @@ func (m Model) validate() error {
|
||||
}
|
||||
continue
|
||||
}
|
||||
// A MIG instance is a device of its own to CUDA, but a process sees
|
||||
// only one, and instances have no NVLink or peer-to-peer between
|
||||
// them: a group of them is neither tensor- nor layer-parallel, it is
|
||||
// a replica that fails at start. One instance, one node, refused here
|
||||
// rather than placed and found out.
|
||||
if discovery.IsMIGClass(p.GPUClass) && (p.GPUsPerNode > 1 || p.Nodes > 1 || p.TP > 1 || p.PP > 1) {
|
||||
return fmt.Errorf("model %q profile %q: %s is a MIG instance, and a replica runs on exactly one: "+
|
||||
"a process can open only one MIG device, and instances have no NVLink between them. "+
|
||||
"Give it tp 1 and one GPU on one node, or use a whole-card class or a larger MIG profile",
|
||||
m.Name, p.Name, p.GPUClass)
|
||||
}
|
||||
// llama.cpp on GPUs splits a model across one node's cards by layer,
|
||||
// and how many is gpus_per_node. Not tp: llama.cpp has no tensor
|
||||
// parallelism, and a tp it was given was a width nothing placed — the
|
||||
|
||||
@@ -0,0 +1,38 @@
|
||||
package catalog
|
||||
|
||||
import (
|
||||
"strings"
|
||||
"testing"
|
||||
)
|
||||
|
||||
func TestAProfileOnAMIGClassRunsOnExactlyOneInstance(t *testing.T) {
|
||||
// One instance, by default or said outright, is a profile like any other.
|
||||
for _, p := range []Profile{
|
||||
{Name: "vllm", Engine: "vllm", GPUClass: "a100-80g-mig-3g.40gb"},
|
||||
{Name: "llama", Engine: "llamacpp", GPUClass: "a100-80g-mig-3g.40gb", GPUsPerNode: 1, TP: 1},
|
||||
} {
|
||||
c, err := New([]Model{model("m", p)})
|
||||
if err != nil {
|
||||
t.Fatalf("%s on one MIG instance: %v", p.Name, err)
|
||||
}
|
||||
m, _ := c.Resolve("m")
|
||||
if pl := m.PlacementProfiles()[0]; pl.GPUsPerNode != 1 || pl.Nodes != 1 {
|
||||
t.Errorf("%s: placement asked for %+v", p.Name, pl)
|
||||
}
|
||||
}
|
||||
// More than one is refused where the model is defined: a process opens
|
||||
// one MIG device, and instances have no NVLink between them, so the
|
||||
// replica would be placed and then fail at start.
|
||||
for _, p := range []Profile{
|
||||
{Name: "tp2", Engine: "vllm", GPUClass: "a100-80g-mig-3g.40gb", TP: 2},
|
||||
{Name: "pp2", Engine: "vllm", GPUClass: "a100-80g-mig-3g.40gb", TP: 1, PP: 2, GPUsPerNode: 2},
|
||||
{Name: "nodes", Engine: "vllm", GPUClass: "a100-80g-mig-3g.40gb", TP: 2, Nodes: 2, GPUsPerNode: 1},
|
||||
{Name: "layers", Engine: "llamacpp", GPUClass: "a100-80g-mig-3g.40gb", GPUsPerNode: 2},
|
||||
{Name: "old-tp", Engine: "llamacpp", GPUClass: "a100-80g-mig-3g.40gb", TP: 2},
|
||||
} {
|
||||
_, err := New([]Model{model("m", p)})
|
||||
if err == nil || !strings.Contains(err.Error(), "MIG instance") {
|
||||
t.Errorf("%s: %v", p.Name, err)
|
||||
}
|
||||
}
|
||||
}
|
||||
@@ -430,8 +430,18 @@ func (c *Collector) Collect(ch chan<- prometheus.Metric) {
|
||||
byClass[class]++
|
||||
labels := []string{n.ID, strconv.Itoa(g.Index), class}
|
||||
|
||||
s, fresh := sensorFor(n.Load, g.Index, now)
|
||||
if fresh && s.Busy() {
|
||||
// The sensors are the card's. A MIG instance shares its card's
|
||||
// heat and power, but not its memory, and has no utilisation of
|
||||
// its own that any driver reports: its memory is the instance's
|
||||
// own reading, and its utilisation is left out rather than
|
||||
// published as the card's or as zero.
|
||||
s, fresh := sensorFor(n.Load, g.CardIndex(), now)
|
||||
if g.IsMIG() {
|
||||
ch <- prometheus.MustNewConstMetric(c.gpuMemoryTotal, prometheus.GaugeValue,
|
||||
float64(g.MemoryTotalMB)*1024*1024, labels...)
|
||||
ch <- prometheus.MustNewConstMetric(c.gpuMemoryUsed, prometheus.GaugeValue,
|
||||
float64(g.MemoryUsedMB)*1024*1024, labels...)
|
||||
} else if fresh && s.Busy() {
|
||||
// What the card is doing now, sampled every heartbeat.
|
||||
c.gpuBusy(ch, s, labels)
|
||||
} else {
|
||||
|
||||
@@ -0,0 +1,36 @@
|
||||
package fleetmetrics
|
||||
|
||||
import (
|
||||
"strings"
|
||||
"testing"
|
||||
"time"
|
||||
|
||||
"gitea.mynodes.xyz/ilker/llmgw/internal/agent/discovery"
|
||||
"gitea.mynodes.xyz/ilker/llmgw/internal/control/inventory"
|
||||
)
|
||||
|
||||
func TestAMIGInstanceHasItsOwnMemoryItsCardsHeatAndNoUtilisation(t *testing.T) {
|
||||
// Card 0 in MIG mode: the sensor sample is the card's, 60 GB used across
|
||||
// both instances and a utilisation the driver does not give per instance.
|
||||
inst := discovery.GPU{Index: 1001, Name: "NVIDIA A100-SXM4-80GB MIG 3g.40gb", MemoryTotalMB: 40192, MemoryUsedMB: 21000,
|
||||
MIG: &discovery.MIGDevice{ParentIndex: 0, ParentMemoryTotalMB: 81920, Device: 1, Profile: "3g.40gb"}}
|
||||
n := inventory.Node{ID: "g1", State: inventory.Ready, GPUs: []discovery.GPU{inst},
|
||||
Load: &inventory.Load{At: time.Now(), GPUs: []inventory.GPUSensor{{Index: 0, TempC: 61, PowerW: 250,
|
||||
UtilPercent: 0, MemoryUsedMB: 60000, MemoryTotalMB: 81920}}}}
|
||||
out := gather(t, fakeSource{nodes: []inventory.Node{n}})
|
||||
labels := "class=a100-80g-mig-3g.40gb gpu=1001 node=g1"
|
||||
for _, want := range []string{
|
||||
"llmgw_gpu_memory_used_bytes " + labels + " -> 22020096000\n",
|
||||
"llmgw_gpu_memory_total_bytes " + labels + " -> 42144366592\n",
|
||||
"llmgw_gpu_temperature_celsius " + labels + " -> 61\n",
|
||||
"llmgw_gpu_power_watts " + labels + " -> 250\n",
|
||||
} {
|
||||
if !strings.Contains(out, want) {
|
||||
t.Errorf("missing %s in:\n%s", want, out)
|
||||
}
|
||||
}
|
||||
// Not the card's zero, not anything: absent.
|
||||
if strings.Contains(out, "llmgw_gpu_utilization_percent "+labels) {
|
||||
t.Errorf("a utilisation was published for a MIG instance:\n%s", out)
|
||||
}
|
||||
}
|
||||
@@ -0,0 +1,87 @@
|
||||
package placement
|
||||
|
||||
import (
|
||||
"slices"
|
||||
"strings"
|
||||
"testing"
|
||||
|
||||
"gitea.mynodes.xyz/ilker/llmgw/internal/agent/discovery"
|
||||
"gitea.mynodes.xyz/ilker/llmgw/internal/control/inventory"
|
||||
)
|
||||
|
||||
// migNode is an A100 80GB node as discovery reports it with card 0 cut into
|
||||
// two 3g.40gb instances and card 1 whole.
|
||||
func migNode(id string) inventory.Node {
|
||||
card := discovery.GPU{Name: "NVIDIA A100-SXM4-80GB", MemoryTotalMB: 81920, ComputeCapability: "8.0"}
|
||||
nd := inventory.Node{ID: id, State: inventory.Ready}
|
||||
for dev, uuid := range []string{"MIG-c6d4f1ef", "MIG-0f7c3a2e"} {
|
||||
g := card
|
||||
g.Index, g.UUID, g.MemoryTotalMB = discovery.MIGIndex(0, dev), uuid, 40192
|
||||
g.Name += " MIG 3g.40gb"
|
||||
g.MIG = &discovery.MIGDevice{ParentIndex: 0, ParentMemoryTotalMB: 81920, Device: dev, Profile: "3g.40gb"}
|
||||
nd.GPUs = append(nd.GPUs, g)
|
||||
}
|
||||
whole := card
|
||||
whole.Index, whole.UUID = 1, "GPU-whole"
|
||||
// NVLink to the card in MIG mode, as topo -m still reports it: nothing
|
||||
// may take that for a link an instance can use.
|
||||
whole.NVLinkPeers = []int{0}
|
||||
nd.GPUs = append(nd.GPUs, whole)
|
||||
return nd
|
||||
}
|
||||
|
||||
func TestAModelIsPlacedOnAMIGInstanceOfItsClass(t *testing.T) {
|
||||
st := store(migNode("n1"))
|
||||
s := New(st)
|
||||
p := Profile{Name: "mig", GPUClass: "a100-80g-mig-3g.40gb", GPUsPerNode: 1}
|
||||
|
||||
res := s.Place([]Profile{p}, nil)
|
||||
if res.Placement == nil {
|
||||
t.Fatalf("no placement:\n%s", res.Explain())
|
||||
}
|
||||
got := res.Placement.Nodes[0].GPUIndices
|
||||
if !slices.Equal(got, []int{1000}) {
|
||||
t.Fatalf("placed on %v, want MIG instance 1000", got)
|
||||
}
|
||||
if res.Placement.Pool != "none/a100-80g-mig-3g.40gb" {
|
||||
t.Errorf("pool %q", res.Placement.Pool)
|
||||
}
|
||||
|
||||
// The next replica takes the other instance, and the one after finds
|
||||
// none: the whole card beside them is another class.
|
||||
st.Allocate("n1", inventory.Allocation{ShardID: "s1", ReplicaID: "r1", GPUIndices: got})
|
||||
res = s.Place([]Profile{p}, nil)
|
||||
if res.Placement == nil || !slices.Equal(res.Placement.Nodes[0].GPUIndices, []int{1001}) {
|
||||
t.Fatalf("second replica: %+v\n%s", res.Placement, res.Explain())
|
||||
}
|
||||
st.Allocate("n1", inventory.Allocation{ShardID: "s2", ReplicaID: "r2", GPUIndices: []int{1001}})
|
||||
if res = s.Place([]Profile{p}, nil); res.Placement != nil {
|
||||
t.Errorf("a third replica was placed on %v", res.Placement.Nodes[0].GPUIndices)
|
||||
}
|
||||
|
||||
// A whole-card profile takes the whole card, never an instance.
|
||||
res = s.Place([]Profile{{Name: "whole", GPUClass: "a100-80g", GPUsPerNode: 1}}, nil)
|
||||
if res.Placement == nil || !slices.Equal(res.Placement.Nodes[0].GPUIndices, []int{1}) {
|
||||
t.Errorf("whole-card profile: %+v\n%s", res.Placement, res.Explain())
|
||||
}
|
||||
}
|
||||
|
||||
func TestMoreThanOneMIGInstanceForAReplicaIsRefused(t *testing.T) {
|
||||
// Two instances are free on one node, which is what a tp 2 profile would
|
||||
// otherwise be given — and fail at start, since a process opens only one
|
||||
// MIG device and instances have no NVLink between them.
|
||||
s := New(store(migNode("n1"), migNode("n2")))
|
||||
for _, p := range []Profile{
|
||||
{Name: "tp2", GPUClass: "a100-80g-mig-3g.40gb", GPUsPerNode: 2},
|
||||
{Name: "two-nodes", GPUClass: "a100-80g-mig-3g.40gb", GPUsPerNode: 1, Nodes: 2},
|
||||
} {
|
||||
res := s.Place([]Profile{p}, nil)
|
||||
if res.Placement != nil {
|
||||
t.Errorf("%s was placed: %+v", p.Name, res.Placement.Nodes)
|
||||
continue
|
||||
}
|
||||
if !strings.Contains(res.Explain(), "a replica runs on exactly one") {
|
||||
t.Errorf("%s refused without saying why:\n%s", p.Name, res.Explain())
|
||||
}
|
||||
}
|
||||
}
|
||||
@@ -156,6 +156,15 @@ func (s *Scheduler) Place(profiles []Profile, avoid []string) Result {
|
||||
|
||||
for _, raw := range ordered {
|
||||
p := raw.normalize()
|
||||
// The catalog refuses these; a profile that reaches here some other
|
||||
// way is refused again rather than placed on instances that cannot
|
||||
// work together. MIG instances are placed one to a replica.
|
||||
if discovery.IsMIGClass(p.GPUClass) && (p.GPUsPerNode > 1 || p.Nodes > 1) {
|
||||
res.Rejections = append(res.Rejections, Rejection{Profile: p.Name, Pool: "none/" + p.GPUClass,
|
||||
Reason: fmt.Sprintf("asks for %d MIG instances on %d nodes, but a replica runs on exactly one",
|
||||
p.GPUsPerNode*p.Nodes, p.Nodes)})
|
||||
continue
|
||||
}
|
||||
if p.Nodes == 1 {
|
||||
if pl, rej := s.placeSingleNode(p, avoid); pl != nil {
|
||||
res.Placement = pl
|
||||
|
||||
@@ -17,6 +17,7 @@ import (
|
||||
"path/filepath"
|
||||
"slices"
|
||||
"sort"
|
||||
"strconv"
|
||||
"strings"
|
||||
"time"
|
||||
|
||||
@@ -57,6 +58,10 @@ type Facts struct {
|
||||
GPUError string `json:"gpu_error,omitempty"`
|
||||
TopoRaw string `json:"topo_raw,omitempty"`
|
||||
TopoErr string `json:"topo_error,omitempty"`
|
||||
// MIG is each MIG-capable card's mode and instances; MIGErr why it could
|
||||
// not be read.
|
||||
MIG []discovery.MIGCard `json:"mig,omitempty"`
|
||||
MIGErr string `json:"mig_error,omitempty"`
|
||||
// NVSwitch is set when the machine has NVSwitch devices, which need the
|
||||
// fabric manager running before CUDA will start.
|
||||
NVSwitch bool `json:"nvswitch"`
|
||||
@@ -150,6 +155,16 @@ func Collect(ctx context.Context, o Options) Facts {
|
||||
}
|
||||
f.GPUs = gpus
|
||||
f.IMEX = discovery.DiscoverIMEX(ctx)
|
||||
if slices.ContainsFunc(gpus, func(g discovery.GPU) bool {
|
||||
cc, _ := strconv.ParseFloat(g.ComputeCapability, 64)
|
||||
return g.IsMIG() || cc >= 8
|
||||
}) {
|
||||
if mig, err := discovery.DiscoverMIG(ctx, smi); err != nil {
|
||||
f.MIGErr = err.Error()
|
||||
} else {
|
||||
f.MIG = mig
|
||||
}
|
||||
}
|
||||
}
|
||||
if m, _ := filepath.Glob("/dev/nvidia-nvswitch*"); len(m) > 0 {
|
||||
f.NVSwitch = true
|
||||
@@ -367,17 +382,22 @@ func Evaluate(f Facts) []Finding {
|
||||
add(OK, "gpu", fmt.Sprintf("%d GPUs: %s", len(f.GPUs), gpuNames(f.GPUs)), "")
|
||||
for _, g := range f.GPUs {
|
||||
if !g.Health.OK() {
|
||||
add(Warn, "gpu", fmt.Sprintf("GPU %d is kept out of placement: %s", g.Index, strings.Join(g.Health.Problems, "; ")), "")
|
||||
add(Warn, "gpu", fmt.Sprintf("GPU %s is kept out of placement: %s",
|
||||
discovery.DeviceLabel(g.Index), strings.Join(g.Health.Problems, "; ")), "")
|
||||
}
|
||||
}
|
||||
}
|
||||
evaluateMIG(f, add)
|
||||
if f.NVSwitch && f.FabricManager != "active" {
|
||||
add(Fail, "nvlink", "this machine has NVSwitch but nvidia-fabricmanager is "+f.FabricManager+
|
||||
": CUDA will not initialise on its GPUs",
|
||||
"systemctl enable --now nvidia-fabricmanager (its version must match the driver's)")
|
||||
}
|
||||
if len(f.GPUs) > 1 {
|
||||
pairs, groups := nvlinkGroups(f.GPUs)
|
||||
// NVLink is between whole cards: a MIG instance has none to report, and
|
||||
// counting instances would call a node of MIG cards one without NVLink.
|
||||
cards := slices.DeleteFunc(slices.Clone(f.GPUs), discovery.GPU.IsMIG)
|
||||
if len(cards) > 1 {
|
||||
pairs, groups := nvlinkGroups(cards)
|
||||
switch {
|
||||
case f.TopoErr != "":
|
||||
add(Warn, "nvlink", "could not read nvidia-smi topo -m: "+f.TopoErr+
|
||||
@@ -393,7 +413,7 @@ func Evaluate(f Facts) []Finding {
|
||||
|
||||
// --- multi-node NVLink ---
|
||||
domain := ""
|
||||
for _, g := range f.GPUs {
|
||||
for _, g := range cards {
|
||||
fb := g.Fabric
|
||||
if fb == nil || strings.EqualFold(fb.State, "Not Supported") {
|
||||
continue
|
||||
@@ -662,6 +682,64 @@ func rank(l Level) int {
|
||||
return 3
|
||||
}
|
||||
|
||||
// evaluateMIG reports each MIG-capable card's mode and instances. Quiet for a
|
||||
// card with MIG off, which is every card on most machines; what it warns of
|
||||
// are the states in which a card is in MIG mode and nothing can run on it.
|
||||
func evaluateMIG(f Facts, add func(Level, string, string, string)) {
|
||||
if f.MIGErr != "" {
|
||||
add(Warn, "mig", "could not read the cards' MIG state: "+f.MIGErr, "run nvidia-smi -q by hand")
|
||||
return
|
||||
}
|
||||
for _, c := range f.MIG {
|
||||
card := fmt.Sprintf("GPU %d (%s)", c.Index, c.Name)
|
||||
if c.Enabled != c.PendingEnabled {
|
||||
want := "off"
|
||||
if c.PendingEnabled {
|
||||
want = "on"
|
||||
}
|
||||
add(Warn, "mig", fmt.Sprintf("%s has MIG turning %s at its next reset, and until then runs as before", card, want),
|
||||
fmt.Sprintf("reset the card when nothing runs on it: nvidia-smi -i %d -r (or reboot)", c.Index))
|
||||
}
|
||||
if !c.Enabled {
|
||||
continue
|
||||
}
|
||||
// A GPU instance with no compute instance is carved but not usable:
|
||||
// it is not a device until one is made inside it.
|
||||
var bare []string
|
||||
for _, gi := range c.GPUInstances {
|
||||
has := slices.ContainsFunc(c.ComputeInstances, func(ci discovery.MIGInstance) bool {
|
||||
return ci.GPUInstance == gi.GPUInstance
|
||||
})
|
||||
if !has {
|
||||
bare = append(bare, fmt.Sprintf("%d (%s)", gi.GPUInstance, gi.Profile))
|
||||
}
|
||||
}
|
||||
switch {
|
||||
case len(c.Instances) == 0 && len(c.GPUInstances) == 0:
|
||||
add(Warn, "mig", card+" is in MIG mode with no instances created: nothing can run on it",
|
||||
fmt.Sprintf("create instances, for example nvidia-smi mig -i %d -cgi 3g.40gb,3g.40gb -C "+
|
||||
"(nvidia-smi mig -i %d -lgip lists the profiles), or turn MIG off: nvidia-smi -i %d -mig 0",
|
||||
c.Index, c.Index, c.Index))
|
||||
case len(c.Instances) == 0:
|
||||
add(Warn, "mig", fmt.Sprintf("%s is in MIG mode with GPU instances %s but no compute instances: nothing can run on it",
|
||||
card, strings.Join(bare, ", ")),
|
||||
fmt.Sprintf("create them: nvidia-smi mig -i %d -cci", c.Index))
|
||||
default:
|
||||
var names []string
|
||||
for _, in := range c.Instances {
|
||||
names = append(names, fmt.Sprintf("%d: %s %s", in.Device, in.Profile, in.UUID))
|
||||
}
|
||||
add(OK, "mig", fmt.Sprintf("%s is in MIG mode with %d instance(s), each a device of its own: %s",
|
||||
card, len(c.Instances), strings.Join(names, "; ")), "")
|
||||
if len(bare) > 0 {
|
||||
add(Warn, "mig", fmt.Sprintf("%s has GPU instances %s with no compute instance, which are not devices yet",
|
||||
card, strings.Join(bare, ", ")),
|
||||
fmt.Sprintf("create them: nvidia-smi mig -i %d -cci, or destroy the GPU instances", c.Index))
|
||||
}
|
||||
}
|
||||
}
|
||||
}
|
||||
|
||||
func gpuNames(gpus []discovery.GPU) string {
|
||||
count := map[string]int{}
|
||||
var order []string
|
||||
|
||||
@@ -0,0 +1,80 @@
|
||||
package doctor
|
||||
|
||||
import (
|
||||
"strings"
|
||||
"testing"
|
||||
|
||||
"gitea.mynodes.xyz/ilker/llmgw/internal/agent/discovery"
|
||||
)
|
||||
|
||||
// migFacts is the healthy node with card 0 in MIG mode, as given.
|
||||
func migFacts(card discovery.MIGCard) Facts {
|
||||
f := healthy()
|
||||
f.MIG = []discovery.MIGCard{card}
|
||||
return f
|
||||
}
|
||||
|
||||
func TestTheDoctorListsACardsMIGInstances(t *testing.T) {
|
||||
fs := Evaluate(migFacts(discovery.MIGCard{Index: 0, Name: "NVIDIA A100-SXM4-80GB", Enabled: true, PendingEnabled: true,
|
||||
Instances: []discovery.MIGListed{{Device: 0, Profile: "3g.40gb", UUID: "MIG-aaa"}, {Device: 1, Profile: "3g.40gb", UUID: "MIG-bbb"}},
|
||||
GPUInstances: []discovery.MIGInstance{{GPU: 0, Profile: "3g.40gb", GPUInstance: 1, ComputeInstance: -1},
|
||||
{GPU: 0, Profile: "3g.40gb", GPUInstance: 2, ComputeInstance: -1}},
|
||||
ComputeInstances: []discovery.MIGInstance{{GPU: 0, Profile: "3g.40gb", GPUInstance: 1},
|
||||
{GPU: 0, Profile: "3g.40gb", GPUInstance: 2}},
|
||||
}))
|
||||
has(t, fs, OK, "GPU 0 (NVIDIA A100-SXM4-80GB) is in MIG mode with 2 instance(s)")
|
||||
has(t, fs, OK, "1: 3g.40gb MIG-bbb")
|
||||
for _, f := range fs {
|
||||
if f.Area == "mig" && f.Level != OK {
|
||||
t.Errorf("a card with its instances made was warned of: %+v", f)
|
||||
}
|
||||
}
|
||||
}
|
||||
|
||||
func TestTheDoctorWarnsOfMIGEnabledWithNoInstances(t *testing.T) {
|
||||
// The state a card is left in by nvidia-smi -mig 1 alone: in MIG mode,
|
||||
// so CUDA will not open it whole, and nothing carved to open instead.
|
||||
fs := Evaluate(migFacts(discovery.MIGCard{Index: 0, Name: "NVIDIA A100-SXM4-80GB", Enabled: true, PendingEnabled: true}))
|
||||
has(t, fs, Warn, "is in MIG mode with no instances created")
|
||||
for _, f := range fs {
|
||||
if f.Area == "mig" && f.Level == Warn && !strings.Contains(f.Fix, "nvidia-smi mig -i 0 -cgi") {
|
||||
t.Errorf("the fix does not say how to create them: %q", f.Fix)
|
||||
}
|
||||
}
|
||||
|
||||
// GPU instances with no compute instance in them are not devices either.
|
||||
fs = Evaluate(migFacts(discovery.MIGCard{Index: 0, Name: "A100", Enabled: true, PendingEnabled: true,
|
||||
GPUInstances: []discovery.MIGInstance{{GPU: 0, Profile: "7g.80gb", GPUInstance: 0, ComputeInstance: -1}}}))
|
||||
has(t, fs, Warn, "GPU instances 0 (7g.80gb) but no compute instances")
|
||||
|
||||
// A mode change waiting for a reset.
|
||||
fs = Evaluate(migFacts(discovery.MIGCard{Index: 0, Name: "A100", Enabled: false, PendingEnabled: true}))
|
||||
has(t, fs, Warn, "MIG turning on at its next reset")
|
||||
}
|
||||
|
||||
func TestACardWithMIGOffIsNotMentioned(t *testing.T) {
|
||||
fs := Evaluate(migFacts(discovery.MIGCard{Index: 0, Name: "A100"}))
|
||||
for _, f := range fs {
|
||||
if f.Area == "mig" {
|
||||
t.Errorf("a card with MIG off was reported: %+v", f)
|
||||
}
|
||||
}
|
||||
}
|
||||
|
||||
func TestNVLinkIsJudgedBetweenWholeCardsOnly(t *testing.T) {
|
||||
// Every card of the node in MIG mode: the instances have no NVLink, and
|
||||
// that is not a node "without NVLink" to warn about.
|
||||
f := healthy()
|
||||
f.GPUs = nil
|
||||
for card := range 2 {
|
||||
for dev := range 2 {
|
||||
f.GPUs = append(f.GPUs, discovery.GPU{Index: discovery.MIGIndex(card, dev), Name: "A100 MIG 3g.40gb",
|
||||
MIG: &discovery.MIGDevice{ParentIndex: card, Device: dev, Profile: "3g.40gb"}})
|
||||
}
|
||||
}
|
||||
for _, x := range Evaluate(f) {
|
||||
if x.Area == "nvlink" && x.Level != OK {
|
||||
t.Errorf("MIG instances were judged for NVLink: %+v", x)
|
||||
}
|
||||
}
|
||||
}
|
||||
@@ -132,7 +132,14 @@ func fitsOn(m Model, h Hardware, d Demand, p Precision, context int) []Fit {
|
||||
// Powers of two only. Tensor parallelism divides attention heads across
|
||||
// ranks, and an engine that cannot divide them evenly refuses the profile —
|
||||
// so offering tp=3 would produce a plan that fails at launch.
|
||||
for width := 1; width <= h.GPUsPerNode*h.Nodes; width *= 2 {
|
||||
//
|
||||
// One wide on MIG instances, however many there are: a process opens
|
||||
// only one, and they have no NVLink between them.
|
||||
widest := h.GPUsPerNode * h.Nodes
|
||||
if isMIG(h.Class) {
|
||||
widest = min(widest, 1)
|
||||
}
|
||||
for width := 1; width <= widest; width *= 2 {
|
||||
nodes := 1
|
||||
perNode := width
|
||||
if width > h.GPUsPerNode {
|
||||
|
||||
@@ -0,0 +1,69 @@
|
||||
package modelplan
|
||||
|
||||
import (
|
||||
"strings"
|
||||
"testing"
|
||||
)
|
||||
|
||||
const mig3g = "a100-80g-mig-3g.40gb"
|
||||
|
||||
func TestAMIGInstanceIsSizedByItsProfileNotItsCard(t *testing.T) {
|
||||
for class, want := range map[string]int{
|
||||
mig3g: 40, "h100-80g-mig-1g.10gb": 10, "h100-80g-mig-1g.10gb-me": 10, "a100-80g": 80, "a100-80g-mig-": 0,
|
||||
} {
|
||||
if got := MemFromClass(class); got != want {
|
||||
t.Errorf("MemFromClass(%q) = %d, want %d", class, got, want)
|
||||
}
|
||||
}
|
||||
}
|
||||
|
||||
func TestAModelThatFitsOneMIGInstanceIsPlannedOnOne(t *testing.T) {
|
||||
// Four instances free on each of two nodes on a fabric: a 3B fits one,
|
||||
// and a 70B, which no single instance holds, is not spread over several
|
||||
// — a replica cannot use more than one.
|
||||
hw := []Hardware{{Class: mig3g, GPUMemGB: 40, GPUsPerNode: 4, Nodes: 2, Fabric: "ib-a"}}
|
||||
fits := Fits(coder3B, hw, 32768, []Precision{BF16})
|
||||
if len(fits) == 0 {
|
||||
t.Fatal("a 3B does not fit a 40 GB MIG instance")
|
||||
}
|
||||
for _, f := range fits {
|
||||
if f.TP != 1 || f.Nodes != 1 {
|
||||
t.Errorf("planned across MIG instances: %s", f.Describe())
|
||||
}
|
||||
}
|
||||
if fits := Fits(llama70B, hw, 8192, []Precision{BF16}); len(fits) != 0 {
|
||||
t.Errorf("a 70B was planned on MIG instances: %s", fits[0].Describe())
|
||||
}
|
||||
}
|
||||
|
||||
func TestANodeWithACardInMIGModeOffersEachOfItsClasses(t *testing.T) {
|
||||
// Card 0 cut into two 3g.40gb instances, card 1 whole: two classes on
|
||||
// one node, each with its own count.
|
||||
nodes := []PoolNode{{ID: "a100", Class: mig3g, GPUs: 3, FreeGPUs: 3, HostMemGB: 512, HostFreeGB: 400,
|
||||
Kinds: []PoolKind{
|
||||
{Class: mig3g, GPUMemGB: 40, GPUs: 2, FreeGPUs: 2},
|
||||
{Class: "a100-80g", GPUMemGB: 80, GPUs: 1, FreeGPUs: 1},
|
||||
}}}
|
||||
arts := []Artifact{
|
||||
{Name: "q4.gguf", Format: "gguf", Bytes: 9 * gib},
|
||||
{Name: "f16.gguf", Format: "gguf", Bytes: 29 * gib},
|
||||
{Name: "big.gguf", Format: "gguf", Bytes: 60 * gib},
|
||||
}
|
||||
opts := Options(arts, shape14B, nodes, 16384)
|
||||
got := strings.Join(labels(opts), "; ")
|
||||
for _, want := range []string{"q4.gguf 1 × " + mig3g, "f16.gguf 1 × " + mig3g, "big.gguf 1 × a100-80g"} {
|
||||
if !strings.Contains(got, want) {
|
||||
t.Errorf("missing %q in %s", want, got)
|
||||
}
|
||||
}
|
||||
// Sixty gigabytes is more than an instance holds, and two instances are
|
||||
// not one bigger device.
|
||||
if strings.Contains(got, "big.gguf 2 × "+mig3g) {
|
||||
t.Errorf("planned across two MIG instances: %s", got)
|
||||
}
|
||||
for _, o := range opts {
|
||||
if o.Class == mig3g && (o.Hosts != 1 || !o.FreeNow) {
|
||||
t.Errorf("the MIG option counts %d hosts, free %v", o.Hosts, o.FreeNow)
|
||||
}
|
||||
}
|
||||
}
|
||||
@@ -46,8 +46,35 @@ type PoolNode struct {
|
||||
// HostMemGB is its RAM, and HostFreeGB what is unused now.
|
||||
HostMemGB int
|
||||
HostFreeGB int
|
||||
// Kinds are the node's devices by class, for a node with more than one:
|
||||
// a card in MIG mode is one or several classes of instance, and a whole
|
||||
// card beside it another. Empty means Class, GPUMemGB, GPUs and FreeGPUs
|
||||
// say it all.
|
||||
Kinds []PoolKind
|
||||
}
|
||||
|
||||
// PoolKind is one class of a node's devices.
|
||||
type PoolKind struct {
|
||||
Class string
|
||||
GPUMemGB int
|
||||
GPUs int
|
||||
FreeGPUs int
|
||||
}
|
||||
|
||||
// kinds is the node's devices by class.
|
||||
func (n PoolNode) kinds() []PoolKind {
|
||||
if len(n.Kinds) > 0 {
|
||||
return n.Kinds
|
||||
}
|
||||
return []PoolKind{{Class: n.Class, GPUMemGB: n.GPUMemGB, GPUs: n.GPUs, FreeGPUs: n.FreeGPUs}}
|
||||
}
|
||||
|
||||
// isMIG reports whether a class names MIG instances: "a100-80g-mig-3g.40gb".
|
||||
// A replica runs on exactly one, never a group of them, so a plan offers one
|
||||
// instance and nothing wider. Read from the class label, as the card's memory
|
||||
// is, which keeps this package free of the agent's.
|
||||
func isMIG(class string) bool { return strings.Contains(class, "-mig-") }
|
||||
|
||||
// Option is one way to run one artifact.
|
||||
type Option struct {
|
||||
Artifact string `json:"artifact"`
|
||||
@@ -149,11 +176,13 @@ func ggufOptions(a Artifact, kv int64, nodes []PoolNode, bpw float64) []Option {
|
||||
}
|
||||
o := Option{Artifact: a.Name, Format: a.Format, Engine: "llamacpp", Class: c.class,
|
||||
GPUsPerNode: width, Nodes: 1, NeedGB: GB(per), HaveGB: budget, BitsPerWeight: bpw}
|
||||
for _, n := range nodes {
|
||||
if n.Class == c.class && n.GPUs >= width {
|
||||
o.Hosts++
|
||||
if n.FreeGPUs >= width {
|
||||
o.FreeNow = true
|
||||
for _, fab := range c.fabrics {
|
||||
for _, n := range fab.nodes {
|
||||
if n.GPUs >= width {
|
||||
o.Hosts++
|
||||
if n.FreeGPUs >= width {
|
||||
o.FreeNow = true
|
||||
}
|
||||
}
|
||||
}
|
||||
}
|
||||
@@ -196,7 +225,9 @@ func vllmOptions(a Artifact, kv int64, sh Shape, nodes []PoolNode, bpw float64)
|
||||
single = true
|
||||
break
|
||||
}
|
||||
if single {
|
||||
// A MIG instance does not join others, on its node or across a
|
||||
// fabric: what does not fit one does not fit the class.
|
||||
if single || isMIG(c.class) {
|
||||
continue
|
||||
}
|
||||
// Several nodes, a node's full width on each, pipeline-parallel
|
||||
@@ -251,32 +282,42 @@ type fabricPool struct {
|
||||
}
|
||||
|
||||
// classes groups GPU nodes by card, and each by fabric: a replica spans
|
||||
// nodes only within one.
|
||||
// nodes only within one. A node with devices of several classes is in each
|
||||
// class's pool, as the node it is for that class: its devices of that class
|
||||
// and no others.
|
||||
func classes(nodes []PoolNode) []classPool {
|
||||
by := map[string]*classPool{}
|
||||
var order []string
|
||||
for _, n := range nodes {
|
||||
if n.Class == "" || n.GPUs == 0 || n.GPUMemGB == 0 {
|
||||
continue
|
||||
}
|
||||
c := by[n.Class]
|
||||
if c == nil {
|
||||
c = &classPool{class: n.Class, mem: n.GPUMemGB}
|
||||
by[n.Class] = c
|
||||
order = append(order, n.Class)
|
||||
}
|
||||
c.maxGPUs = max(c.maxGPUs, n.GPUs)
|
||||
i := -1
|
||||
for j := range c.fabrics {
|
||||
if c.fabrics[j].name == n.Fabric {
|
||||
i = j
|
||||
for _, node := range nodes {
|
||||
for _, k := range node.kinds() {
|
||||
if k.Class == "" || k.GPUs == 0 || k.GPUMemGB == 0 {
|
||||
continue
|
||||
}
|
||||
n := node
|
||||
n.Class, n.GPUMemGB, n.GPUs, n.FreeGPUs, n.Kinds = k.Class, k.GPUMemGB, k.GPUs, k.FreeGPUs, nil
|
||||
if isMIG(n.Class) {
|
||||
// One instance a replica, however many the node has.
|
||||
n.GPUs, n.FreeGPUs = min(n.GPUs, 1), min(n.FreeGPUs, 1)
|
||||
}
|
||||
c := by[n.Class]
|
||||
if c == nil {
|
||||
c = &classPool{class: n.Class, mem: n.GPUMemGB}
|
||||
by[n.Class] = c
|
||||
order = append(order, n.Class)
|
||||
}
|
||||
c.maxGPUs = max(c.maxGPUs, n.GPUs)
|
||||
i := -1
|
||||
for j := range c.fabrics {
|
||||
if c.fabrics[j].name == n.Fabric {
|
||||
i = j
|
||||
}
|
||||
}
|
||||
if i < 0 {
|
||||
c.fabrics = append(c.fabrics, fabricPool{name: n.Fabric})
|
||||
i = len(c.fabrics) - 1
|
||||
}
|
||||
c.fabrics[i].nodes = append(c.fabrics[i].nodes, n)
|
||||
}
|
||||
if i < 0 {
|
||||
c.fabrics = append(c.fabrics, fabricPool{name: n.Fabric})
|
||||
i = len(c.fabrics) - 1
|
||||
}
|
||||
c.fabrics[i].nodes = append(c.fabrics[i].nodes, n)
|
||||
}
|
||||
sort.Strings(order)
|
||||
out := make([]classPool, 0, len(order))
|
||||
@@ -363,8 +404,17 @@ func QuantOf(name string) string {
|
||||
return strings.ToUpper(m[len(m)-1])
|
||||
}
|
||||
|
||||
// MemFromClass reads the card size out of a class label such as "h100-80g".
|
||||
// MemFromClass reads the card size out of a class label such as "h100-80g",
|
||||
// and a MIG instance's out of its profile: 40 for "a100-80g-mig-3g.40gb",
|
||||
// whose card is 80 but whose instance holds 40 of it.
|
||||
func MemFromClass(class string) int {
|
||||
if _, profile, ok := strings.Cut(class, "-mig-"); ok {
|
||||
var compute, gb int
|
||||
if _, err := fmt.Sscanf(profile, "%dg.%dgb", &compute, &gb); err != nil {
|
||||
return 0
|
||||
}
|
||||
return gb
|
||||
}
|
||||
i := strings.LastIndex(class, "-")
|
||||
if i < 0 || !strings.HasSuffix(class, "g") {
|
||||
return 0
|
||||
|
||||
@@ -0,0 +1,54 @@
|
||||
# C22: MIG
|
||||
|
||||
## CHANGELOG
|
||||
|
||||
### MIG instances as GPUs of their own class
|
||||
|
||||
- **A card in MIG mode is placed as its instances.** Discovery reports a card
|
||||
in MIG mode as its MIG instances instead of the whole card, each a device of
|
||||
its own with its UUID (`MIG-…`), its own memory, and a class named from the
|
||||
card's and the profile: two `3g.40gb` instances of an A100 80GB are two
|
||||
devices of class `a100-80g-mig-3g.40gb`. A profile names that class like
|
||||
any other, and placement puts a replica on a free instance of it. Both
|
||||
discovery paths do it: nvidia-smi (instances from `nvidia-smi -L`, their
|
||||
memory and ids from `nvidia-smi -q -x`) and NVML (`GetMigMode`,
|
||||
`GetMaxMigDeviceCount`, `GetMigDeviceHandleByIndex`). llmgw does not create
|
||||
instances; `docs/install.md` has a MIG section on making them.
|
||||
- **One instance a replica.** A process opens only one MIG device, and
|
||||
instances have no NVLink or peer-to-peer between them, so a profile on a
|
||||
MIG class asking for more than one GPU, tp or pp above 1, or more than one
|
||||
node is refused when the model is added, with that reason; placement
|
||||
refuses it again. `ctl model plan` and `ctl model serve` plan an instance
|
||||
for a model one holds and never several together.
|
||||
- **Engines are given the instance by UUID.** Placement numbers card 0's
|
||||
instance 2 as device 1002 (1000 + 100 × card + instance); the agent turns
|
||||
that into `CUDA_VISIBLE_DEVICES=MIG-<uuid>` for vLLM and llama.cpp, and
|
||||
leaves `GGML_VK_VISIBLE_DEVICES` unset (Vulkan cannot see MIG). Every view
|
||||
shows the device as `0/mig2`.
|
||||
- **Memory per instance, no made-up utilisation.** Each instance's memory,
|
||||
and the processes holding it, are its own — read per GPU and compute
|
||||
instance from nvidia-smi's report, so a foreign process on one instance
|
||||
keeps that instance out of placement and not its neighbours. Temperature,
|
||||
power and wear are the card's. No driver reports utilisation per instance,
|
||||
so none is published for one: the console says `n/a on MIG`, and
|
||||
`llmgw_gpu_utilization_percent` has no series for it rather than a zero.
|
||||
- **A card in MIG mode with nothing carved is kept out of placement**, with
|
||||
the reason in `ctl nodes`, since CUDA will not open the whole card while MIG
|
||||
is on.
|
||||
- **`llmgw doctor` reports MIG**: each card's mode and instances, and warns
|
||||
of a card in MIG mode with no instances, of GPU instances with no compute
|
||||
instance, and of a mode change waiting for a reset, with the `nvidia-smi`
|
||||
command for each.
|
||||
- `ctl nodes` counts a node's devices by class when it has MIG instances or
|
||||
more than one class (`a100-80g-mig-3g.40gb×2,a100-80g×1`); the console's
|
||||
GPU list shows instances under their card with their own memory and the
|
||||
card's heat and power, and a node's page lists its classes with counts.
|
||||
`ctl status` and the plan count each device under its own class, where a
|
||||
node's cards were all put under its first class before.
|
||||
- The agent protocol's `GPU` gains `mig` (parent card, its memory, profile,
|
||||
GPU and compute instance ids); the node API's GPUs gain `label`, `class`,
|
||||
`card`, `mig_profile` and memory, and nodes gain `gpus_by_class`.
|
||||
|
||||
## BACKLOG
|
||||
|
||||
**Done (branch `features-c2`):** MIG instances discovered on both paths (nvidia-smi `-L` + `-q -x`; NVML through an interface with a faithful fake) and reported instead of their card, each with its MIG UUID, own memory and class `<card class>-mig-<profile>`; device numbers 1000 + 100 × card + instance, shown as `card/migN`; placement on MIG classes; tp/pp/gpus/nodes above 1 on a MIG class refused in catalog validation and again in placement; `CUDA_VISIBLE_DEVICES=MIG-<uuid>` for vLLM and llama.cpp (no Vulkan device variable on MIG); per-instance memory and processes in heartbeats and the GPU check, card sensors under each instance, utilisation absent rather than zero; doctor MIG findings (`mig -lgi`/`-lci` parsed); `ctl nodes`, console, `ctl status`, `ctl model plan`/`serve` by class; docs/install.md MIG section. Written and tested against fakes only — untested on real MIG hardware. Left: run it on an A100/H100 in MIG mode (check `-L`/`-q -x`/`mig -lgi`/`-lci` and NVML MIG device names against the parsers, and that `CUDA_VISIBLE_DEVICES=MIG-…` reaches vLLM's workers through Ray); instances changed while the agent runs are only seen when it restarts (no rescan); llmgw does not create or reshape instances (no mig-parted integration); quotas count an instance as one GPU, the same as a whole card; SGLang on MIG not checked; device numbers assume fewer than 100 instances per card and that instance numbers stay put while shards run on them.
|
||||
Reference in new issue