Keep every admin table to one line per record
Headers never wrap, free text is clipped with the whole on hover, full-width rows are only notes and forms. The cluster page hides columns empty on every row and shortens node names; People shows two memberships and a count. Co-Authored-By: Claude Opus 5.5 (1M context) <noreply@anthropic.com>
This commit is contained in:
1 parent
7099043c75
commit
235bf33dcd
13 files changed
+146
-38
No files matched your search
@@ -35,7 +35,7 @@
|
||||
<h2>Fabric</h2>
|
||||
<p class="sub">{{if .Node.Fabrics}}On {{join .Node.Fabrics}} · <a href="{{if $.OnAdminListener}}/fabrics{{else}}/admin/fabrics{{end}}">the map →</a>{{else}}<span class="bad">On no fabric: no port a declared fabric names can carry traffic, so no multi-node replica is placed here.</span>{{end}}</p>
|
||||
{{if .Node.IBPorts}}
|
||||
<table><tr><th>Adapter</th><th>State</th><th class="num">Rate</th><th>Fabric</th><th>Physically on</th><th>Errors since boot</th><th class="num">Sent</th><th class="num">Received</th></tr>
|
||||
<table class="rows"><tr><th>Adapter</th><th>State</th><th class="num">Rate</th><th>Fabric</th><th>Physically on</th><th>Errors since boot</th><th class="num">Sent</th><th class="num">Received</th></tr>
|
||||
{{range .Node.IBPorts}}<tr>
|
||||
<td><code>{{.HCA}}/{{.Port}}</code>{{if eq .LinkLayer "Ethernet"}} <span class="tag">RoCE</span>{{end}}</td>
|
||||
<td class="{{if .Active}}state-ready{{else}}bad{{end}}">{{.State}}{{with .PhysState}} <span class="note">{{.}}</span>{{end}}</td>
|
||||
@@ -60,13 +60,13 @@ the adapter came up: a number that grows is the one to look at.</p>
|
||||
{{if or .Node.NVLinkDomain .Node.IMEX}} · IMEX {{if eq .Node.IMEX "active"}}<span class="state-ready">active</span>, {{.Node.IMEXChannels}} channel{{if ne .Node.IMEXChannels 1}}s{{end}}{{else}}<span class="bad">{{or .Node.IMEX "not installed"}}</span>{{end}}{{end}}
|
||||
</p>
|
||||
<div class="gpu-wiring">
|
||||
<table class="nvl-matrix" aria-label="NVLink between GPUs">
|
||||
<table class="rows nvl-matrix" aria-label="NVLink between GPUs">
|
||||
<tr><th></th>{{range .Node.GPUs}}<th>{{.Index}}</th>{{end}}</tr>
|
||||
{{range $a := .Node.GPUs}}<tr><th>GPU {{$a.Index}}</th>
|
||||
{{range $b := $.Node.GPUs}}{{if eq $a.Index $b.Index}}<td class="self"></td>{{else if hasInt $a.NVLinkPeers $b.Index}}<td class="nv" title="GPU {{$a.Index}} ↔ GPU {{$b.Index}} over NVLink">NV</td>{{else}}<td class="pcie" title="GPU {{$a.Index}} ↔ GPU {{$b.Index}} over PCIe">·</td>{{end}}{{end}}
|
||||
</tr>{{end}}
|
||||
</table>
|
||||
<table class="compact gpu-list">
|
||||
<table class="rows compact gpu-list">
|
||||
<tr><th>GPU</th><th>Name</th><th class="num">NUMA</th><th>Nearest adapter</th><th>Multi-node NVLink</th></tr>
|
||||
{{range .Node.GPUs}}<tr>
|
||||
<td>{{.Index}}</td><td>{{.Name}}</td><td class="num">{{.NUMA}}</td>
|
||||
@@ -82,7 +82,7 @@ traffic between nodes should go: PIX and PXB are under the same PCIe switch, SYS
|
||||
|
||||
<h2>What runs here</h2>
|
||||
{{if .Engines}}
|
||||
<table><tr><th>Model</th><th>Replica</th><th>State</th><th>CPU</th><th class="num">Memory</th></tr>
|
||||
<table class="rows"><tr><th>Model</th><th>Replica</th><th>State</th><th>CPU</th><th class="num">Memory</th></tr>
|
||||
{{range .Engines}}<tr>
|
||||
<td>{{.Model}}</td>
|
||||
<td><code>{{.Replica}}</code></td>
|
||||
|
||||
Reference in new issue
Block a user