Files
rollcall/README.md
T
ilkerandClaude Fable 5.1 d9ae89b295
CI / agent (push) Successful in 3s
CI / site (push) Successful in 2s
CI / go (push) Successful in 1m15s
Rollcall: bare-metal commissioning server, agent, image build, lab and CI
Go server (API, embedded web UI, CLI) backed by PostgreSQL with AES-GCM
sealed BMC secrets; Debian live commissioning agent and live-build recipe;
Proxmox lab with pve-vbmc virtual BMCs; Gitea workflows for CI, releases
and deployment; project website.

Co-Authored-By: Claude Fable 5.1 <noreply@anthropic.com>
2026-10-27 01:29:53 +01:00

6.4 KiB

Rollcall

Rollcall is a small, self-contained commissioning service for bare-metal servers, in the spirit of MAAS enlistment and commissioning, without the rest of MAAS.

A server that PXE-boots for the first time gets an ephemeral Debian live image. The image takes a full hardware inventory (DMI, DIMMs, CPUs, disks, NVMe, NICs, InfiniBand HCAs, GPUs, PCI, LLDP neighbours, TPM), creates an administrator account on the server's BMC through in-band IPMI, reports everything to the Rollcall server and powers the machine off. From then on the server is known: it shows up in the web UI and the CLI, its BMC can be driven through the API, and it will not boot the commissioning image again unless you ask for it.

Everything server-side is one static Go binary: HTTP API, embedded web UI, CLI, PostgreSQL schema management and the PXE bookkeeping.

How it works

unknown server ──PXE──▶ dnsmasq (DHCP+TFTP) ──▶ pxelinux default menu
                                                  │ 8 s timeout
                                                  ▼
                               Debian live image over HTTP (kernel+initrd via TFTP,
                               squashfs via HTTP, runs entirely from RAM)
                                                  │
                      rollcall-agent: inventory + BMC user + POST /api/v1/commission
                                                  │
                     rollcall server: PostgreSQL ◀─┘──▶ writes pxelinux.cfg/01-<mac>
                                                       (next boot: "commissioned → power off")
  • Enlist: a machine is identified by its DMI system UUID (fallback: serial, then boot MAC). First contact creates it in state new.
  • Commission: the inventory upload moves it to ready. The BMC password the agent generated is sealed with AES-256-GCM (key in /etc/rollcall/master.key) before it touches the database. It never leaves the server again: power and boot-device operations run ipmitool server-side.
  • Re-commission: removes the per-MAC PXE override; optionally sets bootdev=pxe and power-cycles the machine through its BMC.

Repository layout

Path What
cmd/rollcall/ Go server + CLI + embedded web UI (web/)
agent/ rollcall-agent.py (runs inside the live image), its systemd unit, build-image.sh (live-build recipe)
deploy/ install.sh, rollcall.service, config.example.json, pxelinux-default
lab/ Proxmox test lab: pve-vbmc (virtual IPMI BMC for VMs backed by the Proxmox API), cloud-init for the PXE server VM
site/ Project website (static)
.gitea/workflows/ CI (fmt/vet/build/tests), release on tags, deploy on push to main

Server

# build
cd cmd/rollcall && CGO_ENABLED=0 go build -trimpath -ldflags="-s -w" -o rollcall .

# PostgreSQL role + database
sudo -u postgres psql -c "CREATE ROLE rollcall LOGIN PASSWORD '...';" -c "CREATE DATABASE rollcall OWNER rollcall;"

# config (see deploy/config.example.json), tokens from `rollcall keygen`
sudo install -d -m 0750 /etc/rollcall && sudo install -m 0640 config.json /etc/rollcall/config.json

# install binary, systemd unit, pxelinux menu, tftp symlinks
cd deploy && sudo ./install.sh

config.json keys: listen, image_dir (served under /rollcall/), tftp_root, database_url, master_key_file, admin_token (web UI + management API), agent_token (what the live image presents), commission_append (kernel command line baked into generated PXE files), bmc_hints (out-of-band BMC mapping for machines without in-band IPMI, e.g. VMs).

CLI (same binary)

rollcall list
rollcall show m-2ef1dab828c8 [-json]
rollcall events m-2ef1dab828c8
rollcall power m-2ef1dab828c8 status|on|off|soft|cycle|reset
rollcall bootdev m-2ef1dab828c8 pxe|disk|cdrom|bios|none
rollcall recommission m-2ef1dab828c8 [-now]
rollcall delete m-2ef1dab828c8

Reads ROLLCALL_URL / ROLLCALL_TOKEN, or the config file when readable.

API

Method Path Auth Purpose
POST /api/v1/commission agent token inventory upload from the live image
GET /api/v1/bmc-hint?macs= agent token out-of-band BMC hint for VMs
GET /api/v1/machines admin list (summaries)
GET /api/v1/machines/{id} admin full record: inventory, BMC (no secret), events
POST /api/v1/machines/{id}/power admin {"action":"on"} etc., runs ipmitool server-side
POST /api/v1/machines/{id}/bootdev admin {"device":"pxe"}
POST /api/v1/machines/{id}/recommission[?now=1] admin boot the image again on next PXE (now=1: via BMC immediately)
DELETE /api/v1/machines/{id} admin forget the machine
GET /rollcall/* none image files (kernel, initrd, squashfs)
GET / token in browser web UI

Admin auth is Authorization: Bearer <admin_token>; the agent sends X-Rollcall-Token.

Commissioning image

agent/build-image.sh builds a Debian 13 live image with live-build (about 8 minutes, ~780 MB squashfs). It contains the full Debian kernel with non-free firmware, ipmitool, freeipmi, rdma-core, infiniband-diags, mstflint, nvme-cli, smartmontools, lldpd, lshw and an SSH server (root, key only) for debugging. Output goes to image_dir.

Kernel parameters understood by the agent: rollcall.server=URL (required), rollcall.token=…, rollcall.bmcuser=NAME (default commissioner), rollcall.nopoweroff (stay up after reporting).

BMC account

In-band (/dev/ipmi0): find the LAN channel, pick the existing commissioner slot or the first empty user ID ≥ 3, set name/password, ADMINISTRATOR privilege, channel access, enable, SOL payload. The password is random (16 chars) and is reported once to the server. If no in-band IPMI exists the agent asks the server for a hint (bmc_hints) and verifies it out-of-band.

Vendor quirks (iDRAC/iLO password policies, missing empty slots) are reported in bmc.errors and visible in the UI.

Lab

lab/ documents a Proxmox SDN test setup: an isolated vnet, a PXE server VM running dnsmasq + Rollcall, two diskless VMs, and pve-vbmc, a tiny IPMI-over-LAN BMC emulator that drives VMs through the Proxmox API so that ipmitool power on and chassis bootdev pxe work against virtual machines.

Status