Cabling: BMC ports to the out-of-band switches, NetBox cables, cables by hand
The host's LLDP never sees the BMC's own port. A port's cable now comes
from LLDP first (what is really there), then from a cable recorded in
NetBox on the machine's device (read with the layout, traced through
patch panels to the far interface via connected_endpoints), then from
one entered by hand (POST/DELETE /api/v1/cables, the pencil in the
cabling list). A NetBox interface marked management-only or named like
a BMC (iDRAC, iLO, XCC, IMM, IPMI, BMC, OOB, mgmt) is the machine's
"bmc" port, so BMCs get their cable to the out-of-band switch. When
NetBox records another switch port than LLDP sees, the port says what
NetBox says.

A switch whose NetBox role names out-of-band or management, or that
only BMCs are cabled to, is marked OOB. In 3D the BMC cable leaves the
BMC port on the back (thinner); the side panel lists every machine's
ports with their source, the BMC always, and switches carry an OOB tag.
Estimated switch places now go around the units placed switches take.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-11-01 13:05:17 +01:00
..