Server heights from firmware and model; rack elevation at real size
CI / agent (push) Successful in 3s
CI / site (push) Successful in 2s
CI / go (push) Successful in 41s

Nobody types in how many units a server takes. Commissioning reads the
SMBIOS chassis height; without one the model decides, from a table of
heights checked against vendor documentation (Dell, HPE, Lenovo,
xFusion, Fujitsu, Inspur/KAYTUS, GIGABYTE; Supermicro model numbers do
not carry the height), and rack_units in config.json covers the rest and
overrides both. Sleds of a multi-node chassis share its units.

NetBox device types get the height (0 for sleds, which go into the rack
without a position; Rollcall's own types are corrected). The rack
elevation spans each server over its height, draws a chassis's sleds as
one block, marks unknown heights and lists overlaps.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
This commit is contained in:
Ilker ManapandClaude Opus 5.5 committed 2026-10-31 19:16:10 +01:00
1 parent 355401465c
commit 9b0b27fce6
12 files changed
+290 -16

No files matched your search

+7
View File
@@ -90,6 +90,13 @@ def dmi_system():
# fallbacks via sysfs
d["system-uuid"] = d["system-uuid"] or readf("/sys/class/dmi/id/product_uuid")
d["system-serial-number"] = d["system-serial-number"] or readf("/sys/class/dmi/id/product_serial")
# SMBIOS type 3: the enclosure's height in rack units ("2 U"; often "Unspecified")
# and power cords; the region falls back to the model when the height is missing
for b in dmi_blocks(3)[:1]:
m = re.match(r"(\d+)\s*U\b", b.get("Height", ""))
d["chassis-height-u"] = int(m.group(1)) if m else None
cords = b.get("Number Of Power Cords", "")
d["chassis-power-cords"] = int(cords) if cords.isdigit() else None
return d