Files
llmgw/docs/node-onboarding.md
T
Ilker ManapandClaude Opus 5 c97b671ef9
CI / test (push) Successful in 1m29s
Prove the multi-node path on a simulated cluster
Phase 4 had been written and never run. The hardware is not coming, so the
cluster is simulated instead — four nodes across two fabrics, eight GPUs each,
built with the onboarding scripts from the previous commit.

`sim` is now an engine adapter, not just a standalone command. Its leader binds
a rendezvous port and does not serve until every worker has joined; its workers
serve nothing at all. That is the part stub processes could never exercise, and
it is why this path survived four phases untested: the command line was
checked, the sequence was not.

Measured on the cluster:

- a 2-node replica on each fabric, node01+node02 on ib-a and node03+node04 on
  ib-b, four GPUs from each
- a request served through one of them
- only the leader listening — node02 had no port open at all, which is
  ServesHTTP working end to end rather than in a unit test
- node02 killed; at t+60s it was declared lost, the ib-a replica failed and was
  reaped; at t+80s a replacement was ready on ib-b, the fabric that could still
  host it, while node01 sat idle rather than being paired across fabrics

The invariant held under the one condition that tests it: when a replica could
not be rebuilt where it was, it moved to a fabric that could hold all of it
rather than spanning two.

What this does not prove is written into the plan next to what it does. The
GPUs are an inventory, the fabric is a sysfs-shaped directory, and the engine
speaks no NCCL — so the launch sequence is now exercised while the launch
arguments for vLLM and SGLang are still read from documentation rather than
from a running engine.

docs/node-onboarding.md is the procedure, including how to run all of this on
machines that have neither GPUs nor InfiniBand.

Co-Authored-By: Claude Opus 5 (1M context) <noreply@anthropic.com>
2026-09-16 12:34:23 +02:00

4.1 KiB

Adding a node

Written for whoever runs the cluster. Two scripts, because the two halves of onboarding are done by different people with different access: one needs the hypervisor, the other needs the certificate authority.

1. The machine

On the Proxmox host:

llmgw-provision-node --vmid 144 --name llmgw-node04 --ip 10.0.0.144/24

Name it after the node id. The VM name, the hostname, the node id and the certificate's common name are all the same string. They do not have to be, and every time they are not, somebody spends an afternoon working out which of the four a message is talking about.

It imports a cloud image and lets cloud-init do the rest, which is why a node takes a minute rather than an afternoon. It refuses to touch an existing VMID: adopting a machine is not a decision a provisioning script should make.

2. The identity

On the host that holds the certificate authority — this is the part that cannot be delegated, because it issues the credential by which the control plane believes the node is who it says it is:

llmgw-onboard-node \
  --node llmgw-node04 \
  --addr 10.0.0.144 \
  --server https://10.0.0.140:7443 \
  --fabric ib-b

It issues a client certificate whose common name is the node id, installs it along with the CA root, trusts that root system-wide so other tooling on the machine stops treating llmgw's certificates as strangers, installs the binary and the unit, and starts the agent. The node appears in llmgw ctl nodes within a few seconds.

If it does not, the control plane's log says why. A certificate whose common name does not match the claimed node id is refused by design — that check is what makes a node's identity something it proves rather than something it picks.

It needs ssh from the CA host to the node. Provisioning copies that host's authorized_keys into the new machine, so a node built by the script above already satisfies it; an older machine may need the key added.

Fabrics

--fabric is how a node says which InfiniBand fabric it is attached to, and there is no way around stating it. OpenSM's default subnet prefix is fe80:: on every fabric, so a matching prefix proves nothing and a wrong guess produces a replica that starts, passes health checks, and then hangs on its first all-reduce.

Omit it for a node with no fabric. Such a node is its own island: it can host single-node replicas and will never be given a multi-node one.

Two adapters per fabric is the default; --fabric ib-b:mlx5_2,mlx5_3 names them explicitly. An adapter must never appear under two fabrics — the agent refuses that configuration, because the consequence is the hang above.

Where the driver is

--nvidia-smi /opt/nvidia/bin/nvidia-smi
--ib-root /sys/class/infiniband

Both default to the usual places. Containerized driver installs routinely put nvidia-smi somewhere else, and an agent that cannot find it registers with no GPUs — which looks exactly like a node that has none.

Removing a node

llmgw ctl drain llmgw-node04     # move its replicas off, one at a time
llmgw ctl nodes                  # wait until it holds none

Then stop the agent. Draining brings each replacement up before stopping the original, which is the difference between a rolling move and an outage.

The node's certificate stays valid until it expires. There is no revocation list — if a machine is decommissioned rather than retired, reissue the authority or accept that a certificate naming a node that no longer exists can still connect and claim to be it.

Testing without hardware

Every part of this works on machines with no GPUs and no InfiniBand. Point --nvidia-smi at a script that prints the CSV discovery asks for, point --ib-root at a sysfs-shaped directory, and use engine: sim in the catalog.

The simulated engine rendezvouses for real: rank 0 binds the dist-init port and does not serve until every worker has joined, and workers serve nothing. That exercises the multi-node launch sequence, the fabric constraint, and failure and rebuild — which is most of what goes wrong — without exercising NCCL, which is the rest.