How much of each GPU works, beside whether anything does
The busy figure is nvidia-smi's utilization.gpu: the share of time any
kernel ran, which a kernel on one SM fills. On cuda01 decode read 92% busy
while the SMs had work 69% of the time and issued on 18% of their cycles.

Busy is now said to be that, and beside it: each card's draw against its
power limit (efficiency table, fleet and node charts, the console's GPU
work chart), and where the profiling counters can be read, SMs active, SM
occupancy, tensor cores and DRAM (llmgw_gpu_*_active_percent), from NVML's
GPM on Hopper and later or a dcgm-exporter on the node
(discovery.dcgm_exporter). The GPU map colours by work by default and keeps
busy as a mode. A MIG instance is never published with its card's profile.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-10-31 20:11:26 +01:00

759 lines
33 KiB
Go

// Package fleetmetrics exports what the cluster is made of and how much of it
// is in use.
//
// The router already exported twenty-two metric families about requests,
// endpoints, admission and scoring — everything about traffic, and nothing
// about the machines serving it. There was no way to graph GPU usage, spot a
// node going unhealthy, watch a fabric fill up, or answer "was the cluster full
// at the time" after an incident, which is the first question anyone asks.
//
// Exported by the control plane rather than by each agent, deliberately. The
// control plane already holds all of it: agents report their hardware at
// registration and their state on every heartbeat, so the data is a map read
// away. One scrape target for a fleet of hundreds, no per-node Prometheus
// configuration, no firewall rule per machine, and nothing new on the nodes.
package fleetmetrics
import (
"strconv"
"strings"
"time"
"github.com/prometheus/client_golang/prometheus"
"gitea.mynodes.xyz/ilker/llmgw/internal/control/fabrics"
"gitea.mynodes.xyz/ilker/llmgw/internal/control/inventory"
"gitea.mynodes.xyz/ilker/llmgw/internal/control/reconciler"
)
// Source is the control plane state this reads.
type Source interface {
Nodes() []inventory.Node
FreeGPUs(nodeID string) []int
Replicas() []reconciler.Replica
}
// Collector reports the fleet on each scrape.
//
// A collector rather than gauges kept up to date by a ticker: the numbers are
// derived from state that already exists, so computing them when asked is both
// simpler and fresher than maintaining a parallel copy that can drift. Nothing
// runs between scrapes.
// HealthSource adds what the reconciler knows about each model and where
// engine installs stand, and whether this control plane is the one placing
// work. Asked for by type assertion, so a source without it — a test's —
// publishes what it did before.
type HealthSource interface {
ModelHealth() []reconciler.ModelHealth
IsLeader() bool
}
type Collector struct {
src Source
modelDesired *prometheus.Desc
modelFailures *prometheus.Desc
modelParked *prometheus.Desc
modelUnplaceable *prometheus.Desc
modelPreempted *prometheus.Desc
capacityHolds *prometheus.Desc
capacityGuarantee *prometheus.Desc
capacityLimit *prometheus.Desc
engineInstall *prometheus.Desc
leader *prometheus.Desc
nodeUp *prometheus.Desc
nodeGPUs *prometheus.Desc
nodeGPUsFree *prometheus.Desc
nodeMemory *prometheus.Desc
nodeSeen *prometheus.Desc
nodeDiskFree *prometheus.Desc
nodeDiskSize *prometheus.Desc
gpuMemoryTotal *prometheus.Desc
gpuMemoryUsed *prometheus.Desc
gpuUtil *prometheus.Desc
gpuAssigned *prometheus.Desc
gpuPCIeReplay *prometheus.Desc
gpuRetired *prometheus.Desc
gpuRetirePend *prometheus.Desc
gpuRemapped *prometheus.Desc
gpuRemapPend *prometheus.Desc
gpuRemapFail *prometheus.Desc
gpuNVLinkErr *prometheus.Desc
gpuXID *prometheus.Desc
gpuLastXID *prometheus.Desc
gpuMemUtil *prometheus.Desc
gpuSMActive *prometheus.Desc
gpuSMOccupancy *prometheus.Desc
gpuTensor *prometheus.Desc
gpuDRAMActive *prometheus.Desc
gpuSMClock *prometheus.Desc
gpuTemp *prometheus.Desc
gpuMemTemp *prometheus.Desc
gpuPower *prometheus.Desc
gpuPowerLimit *prometheus.Desc
gpuThrottled *prometheus.Desc
nodeCPUTemp *prometheus.Desc
nodeCPUPower *prometheus.Desc
nodeInletTemp *prometheus.Desc
gpuHealthy *prometheus.Desc
gpuNVLink *prometheus.Desc
gpuECC *prometheus.Desc
replicaState *prometheus.Desc
replicaIdle *prometheus.Desc
replicaReady *prometheus.Desc
nodeCPU *prometheus.Desc
nodeCPUs *prometheus.Desc
nodeLoad *prometheus.Desc
nodeMemUsed *prometheus.Desc
nodeMemAvail *prometheus.Desc
shardCPU *prometheus.Desc
shardMemory *prometheus.Desc
ibActive *prometheus.Desc
ibRate *prometheus.Desc
ibCounter *prometheus.Desc
gpuNVLJoined *prometheus.Desc
imexUp *prometheus.Desc
fabricSMs *prometheus.Desc
fabricMaster *prometheus.Desc
fabricProblems *prometheus.Desc
}
// loadFresh is how old a node's load may be and still be reported. A node
// that stopped sending it has an unknown load, and repeating its last figure
// would draw a busy machine long after it went away.
const loadFresh = time.Minute
// New builds the collector.
func New(src Source) *Collector {
node := []string{"node"}
gpu := []string{"node", "gpu", "class"}
return &Collector{
src: src,
nodeUp: prometheus.NewDesc("llmgw_node_up",
"1 when a node is ready to take work, 0 otherwise.",
append(node, "state", "fabric"), nil),
nodeGPUs: prometheus.NewDesc("llmgw_node_gpus_total",
"GPUs a node reports.", append(node, "class"), nil),
nodeGPUsFree: prometheus.NewDesc("llmgw_node_gpus_free",
"GPUs on a node that are healthy and unallocated.", node, nil),
nodeMemory: prometheus.NewDesc("llmgw_node_memory_bytes",
"A node's total RAM, 0 when it does not report one.", node, nil),
nodeSeen: prometheus.NewDesc("llmgw_node_last_seen_seconds",
"Seconds since a node last reported. Rising means an agent has gone quiet.", node, nil),
// Only the disk a node fills itself: space on a shared filer is not
// this node's to spend, and summing it per node would have a fleet of
// twenty each report the same free terabyte. Absent rather than zero
// when nothing was reported, so an alert on "free is low" does not
// fire for every node that was never asked about its disk.
nodeDiskFree: prometheus.NewDesc("llmgw_node_disk_free_bytes",
"Free space on the local filesystems holding model weights. Absent when the node reports no storage.", node, nil),
nodeDiskSize: prometheus.NewDesc("llmgw_node_disk_total_bytes",
"Size of those filesystems, so free space can be read as a fraction.", node, nil),
gpuMemoryTotal: prometheus.NewDesc("llmgw_gpu_memory_total_bytes",
"A GPU's framebuffer size.", gpu, nil),
gpuMemoryUsed: prometheus.NewDesc("llmgw_gpu_memory_used_bytes",
"A GPU's framebuffer in use, including processes llmgw did not start.", gpu, nil),
gpuUtil: prometheus.NewDesc("llmgw_gpu_utilization_percent",
"The share of the last sample period in which any kernel ran on a GPU (nvidia-smi's "+
"utilization.gpu). Not how much of the chip: a kernel on one SM reads 100%. Absent "+
"when the driver does not report it, which is not the same as idle. Memory used says "+
"a model is loaded; this says whether it is doing anything, and "+
"llmgw_gpu_sm_active_percent how much.", gpu, nil),
gpuSMActive: prometheus.NewDesc("llmgw_gpu_sm_active_percent",
"The share of time a GPU's SMs had work, averaged over all of them: how much of the chip "+
"the busy figure is using. From NVML's GPM (Hopper and later) or a dcgm-exporter on the node; "+
"absent elsewhere.", gpu, nil),
gpuSMOccupancy: prometheus.NewDesc("llmgw_gpu_sm_occupancy_percent",
"How full a GPU's active SMs were with warps, of the most they can hold.", gpu, nil),
gpuTensor: prometheus.NewDesc("llmgw_gpu_tensor_active_percent",
"The share of time a GPU's tensor cores were working. Low in decode at batch one is normal; "+
"prefill and batches are where it should rise.", gpu, nil),
gpuDRAMActive: prometheus.NewDesc("llmgw_gpu_dram_active_percent",
"The share of time a GPU's memory interface was moving data, from its profiling counters.", gpu, nil),
gpuPCIeReplay: prometheus.NewDesc("llmgw_gpu_pcie_replays",
"PCIe link retries on a GPU's link since the driver loaded; one that keeps climbing is a riser, slot or cable.", gpu, nil),
gpuRetired: prometheus.NewDesc("llmgw_gpu_retired_pages",
"Memory pages retired, by cause (sbe, dbe), on GPUs before Ampere.", append(gpu, "cause"), nil),
gpuRetirePend: prometheus.NewDesc("llmgw_gpu_retirement_pending",
"1 when retired pages wait for a GPU reset to take effect.", gpu, nil),
gpuRemapped: prometheus.NewDesc("llmgw_gpu_remapped_rows",
"Memory rows remapped, by kind (correctable, uncorrectable), on Ampere and later.", append(gpu, "kind"), nil),
gpuRemapPend: prometheus.NewDesc("llmgw_gpu_remap_pending",
"1 when remapped rows wait for a GPU reset to take effect.", gpu, nil),
gpuRemapFail: prometheus.NewDesc("llmgw_gpu_remap_failure",
"1 when a GPU has run out of spare memory rows: it needs replacing.", gpu, nil),
gpuNVLinkErr: prometheus.NewDesc("llmgw_gpu_nvlink_errors",
"NVLink errors summed over a GPU's links, by kind (crc, replay, recovery).", append(gpu, "kind"), nil),
gpuXID: prometheus.NewDesc("llmgw_gpu_xid_errors",
"The driver's XID error events for a GPU since its node's agent started.", gpu, nil),
gpuLastXID: prometheus.NewDesc("llmgw_gpu_last_xid",
"The code of a GPU's last XID error since its agent started; absent when there was none.", gpu, nil),
gpuAssigned: prometheus.NewDesc("llmgw_gpu_assigned",
"1 for each GPU a replica holds: which model, which replica, and whose quota it counts against. "+
"Joined on node and gpu with the other llmgw_gpu_ series, it says what each model's cards are doing.",
[]string{"node", "gpu", "model", "replica", "owner"}, nil),
gpuMemUtil: prometheus.NewDesc("llmgw_gpu_memory_utilization_percent",
"How much of the sample period a GPU's memory was being read or written: "+
"decode is bound by it, so a card busy here and idle above is waiting on memory.", gpu, nil),
gpuSMClock: prometheus.NewDesc("llmgw_gpu_sm_clock_mhz",
"A GPU's streaming multiprocessor clock now; one held low under load is the card being throttled.", gpu, nil),
gpuMemTemp: prometheus.NewDesc("llmgw_gpu_memory_temperature_celsius",
"A GPU's memory (HBM) temperature, where the driver reports it.", gpu, nil),
gpuPower: prometheus.NewDesc("llmgw_gpu_power_watts",
"A GPU's power draw now.", gpu, nil),
gpuPowerLimit: prometheus.NewDesc("llmgw_gpu_power_limit_watts",
"The power limit a GPU is held to.", gpu, nil),
gpuThrottled: prometheus.NewDesc("llmgw_gpu_throttled",
"1 while something holds a GPU's clocks down: sw_power_cap, hw_slowdown, sw_thermal, hw_thermal, power_brake.",
append(gpu, "reason"), nil),
nodeCPUTemp: prometheus.NewDesc("llmgw_node_cpu_temperature_celsius",
"A node's hottest CPU sensor.", node, nil),
nodeCPUPower: prometheus.NewDesc("llmgw_node_cpu_power_watts",
"A node's CPU packages' power draw, from RAPL.", node, nil),
nodeInletTemp: prometheus.NewDesc("llmgw_node_inlet_temperature_celsius",
"A node's inlet or ambient air sensor, where its board has one.", node, nil),
gpuTemp: prometheus.NewDesc("llmgw_gpu_temperature_celsius",
"A GPU's reported temperature.", gpu, nil),
gpuHealthy: prometheus.NewDesc("llmgw_gpu_healthy",
"1 when a GPU is eligible for placement, 0 when a fault keeps it out.", gpu, nil),
gpuNVLink: prometheus.NewDesc("llmgw_gpu_nvlink_peers",
"GPUs reachable over NVLink from this one. Always 0 on an agent built without "+
"the nvml tag, which is every portable binary — so a flat zero across a fleet "+
"means the topology is unknown rather than absent, and tensor groups are being "+
"chosen by index.", gpu, nil),
gpuECC: prometheus.NewDesc("llmgw_gpu_ecc_errors",
"Uncorrected ECC errors on a GPU. Non-zero is why a card stops being scheduled.", gpu, nil),
replicaState: prometheus.NewDesc("llmgw_replicas",
"Replicas by model and state.", []string{"model", "state"}, nil),
replicaReady: prometheus.NewDesc("llmgw_model_replicas_ready",
"Replicas of a model that are serving. Published, as 0 when none are, for every "+
"model that should be running; a stopped model, or an on-demand one nobody is "+
"asking for, publishes nothing.", []string{"model"}, nil),
modelDesired: prometheus.NewDesc("llmgw_model_replicas_desired",
"Replicas a model should have now: its minimum, or for an on-demand model 1 while "+
"it is being asked for.", []string{"model"}, nil),
modelFailures: prometheus.NewDesc("llmgw_model_start_failures",
"Replicas of a model that failed to start in a row. Resets when one comes up.",
[]string{"model"}, nil),
modelParked: prometheus.NewDesc("llmgw_model_parked",
"1 when a model failed so often in a row that it is no longer retried.",
[]string{"model"}, nil),
modelUnplaceable: prometheus.NewDesc("llmgw_model_unplaceable",
"1 when a model is short of replicas and the last attempt found no node to place one on.",
[]string{"model"}, nil),
capacityHolds: prometheus.NewDesc("llmgw_capacity_holds",
"What a part of the tenancy tree holds of a resource, its own models' replicas and those beneath it.",
[]string{"scope", "resource"}, nil),
capacityGuarantee: prometheus.NewDesc("llmgw_capacity_guarantee",
"What a part of the tenancy tree is guaranteed of a resource.",
[]string{"scope", "resource"}, nil),
capacityLimit: prometheus.NewDesc("llmgw_capacity_limit",
"The most of a resource a part of the tenancy tree may hold.",
[]string{"scope", "resource"}, nil),
modelPreempted: prometheus.NewDesc("llmgw_model_preempted_total",
"Replicas of a model stopped to make room for a model of a higher capacity class.",
[]string{"model", "class"}, nil),
engineInstall: prometheus.NewDesc("llmgw_node_engine_install",
"Where installing an engine stands on a node: 1 for the current state.",
[]string{"node", "engine", "version", "state"}, nil),
leader: prometheus.NewDesc("llmgw_control_plane_leader",
"1 when this control plane is the one placing work, 0 when it is a standby.", nil, nil),
replicaIdle: prometheus.NewDesc("llmgw_replica_idle_seconds",
"Seconds since a replica was last sent a request. Absent when nothing has been reported, "+
"which is not the same as idle.", []string{"model", "replica"}, nil),
// A node's own use, from its heartbeat. Absent when the agent has
// not measured it lately, which is not the same as idle.
nodeCPU: prometheus.NewDesc("llmgw_node_cpu_utilization_percent",
"How busy a node's CPUs were between its last two heartbeats, 0 to 100 across all cores.", node, nil),
nodeCPUs: prometheus.NewDesc("llmgw_node_cpus",
"CPUs a node has, so a load average can be read against it.", node, nil),
nodeLoad: prometheus.NewDesc("llmgw_node_load",
"The kernel's load average over 1, 5 and 15 minutes.", append(node, "window"), nil),
nodeMemUsed: prometheus.NewDesc("llmgw_node_memory_used_bytes",
"RAM in use: total less what the kernel could hand to a new process.", node, nil),
nodeMemAvail: prometheus.NewDesc("llmgw_node_memory_available_bytes",
"RAM the kernel could hand to a new process without swapping.", node, nil),
shardCPU: prometheus.NewDesc("llmgw_shard_cpu_cores",
"Cores an engine process group kept busy, the way top counts: 2.5 is two and a half.",
[]string{"node", "model", "replica", "shard"}, nil),
shardMemory: prometheus.NewDesc("llmgw_shard_memory_bytes",
"Resident memory of an engine process group.",
[]string{"node", "model", "replica", "shard"}, nil),
// Every InfiniBand or RoCE port, re-read on each heartbeat.
ibActive: prometheus.NewDesc("llmgw_ib_port_active",
"1 when an InfiniBand or RoCE port can carry traffic. phys_state tells a cable "+
"unplugged (Polling, Disabled) from a link with no subnet manager (LinkUp).",
[]string{"node", "hca", "port", "link_layer", "state", "phys_state"}, nil),
ibRate: prometheus.NewDesc("llmgw_ib_port_rate_gbps",
"A port's negotiated rate. A link that trained below its usual speed is a "+
"cable or transceiver to look at.", []string{"node", "hca", "port"}, nil),
gpuNVLJoined: prometheus.NewDesc("llmgw_gpu_nvlink_joined",
"1 when a GPU is joined to its multi-node NVLink domain, 0 when it reports a fabric it has not "+
"joined. Absent on cards with no multi-node fabric.", []string{"node", "gpu", "domain", "state"}, nil),
imexUp: prometheus.NewDesc("llmgw_imex_up",
"1 when nvidia-imex is active with a channel, on nodes whose GPUs report a fabric.", []string{"node"}, nil),
fabricSMs: prometheus.NewDesc("llmgw_fabric_subnet_managers",
"Subnet managers a physical fabric lists, by state. No standby means the fabric "+
"cannot recover from a change if its master stops.", []string{"fabric", "physical", "state"}, nil),
fabricMaster: prometheus.NewDesc("llmgw_fabric_master_sm",
"1 for a physical fabric's master subnet manager, as most of its ports see it; a "+
"change of sm_guid is a failover.", []string{"fabric", "physical", "sm_guid"}, nil),
fabricProblems: prometheus.NewDesc("llmgw_fabric_problems",
"Disagreements about the fabrics, by level: fail means multi-node work will not "+
"place or will not run where it should.", []string{"level"}, nil),
ibCounter: prometheus.NewDesc("llmgw_ib_port_counter_total",
"A port's cumulative counters, by sysfs name: symbol_error, link_downed and the "+
"other errors say a link is going bad before a job fails on it; port_xmit_data "+
"and port_rcv_data are bytes.", []string{"node", "hca", "port", "counter"}, nil),
}
}
// Describe implements prometheus.Collector.
func (c *Collector) Describe(ch chan<- *prometheus.Desc) {
for _, d := range []*prometheus.Desc{
c.nodeUp, c.nodeGPUs, c.nodeGPUsFree, c.nodeMemory, c.nodeSeen,
c.nodeDiskFree, c.nodeDiskSize,
c.nodeCPU, c.nodeCPUs, c.nodeLoad, c.nodeMemUsed, c.nodeMemAvail, c.shardCPU, c.shardMemory,
c.ibActive, c.ibRate, c.ibCounter, c.fabricSMs, c.fabricMaster, c.fabricProblems,
c.gpuNVLJoined, c.imexUp,
c.gpuMemoryTotal, c.gpuMemoryUsed, c.gpuUtil, c.gpuMemUtil, c.gpuSMClock,
c.gpuSMActive, c.gpuSMOccupancy, c.gpuTensor, c.gpuDRAMActive, c.gpuAssigned, c.gpuTemp, c.gpuHealthy,
c.gpuPCIeReplay, c.gpuRetired, c.gpuRetirePend, c.gpuRemapped, c.gpuRemapPend, c.gpuRemapFail,
c.gpuNVLinkErr, c.gpuXID, c.gpuLastXID,
c.gpuMemTemp, c.gpuPower, c.gpuPowerLimit, c.gpuThrottled, c.nodeCPUTemp, c.nodeCPUPower, c.nodeInletTemp,
c.gpuNVLink, c.gpuECC,
c.replicaState, c.replicaReady, c.replicaIdle,
c.modelDesired, c.modelFailures, c.modelParked, c.modelUnplaceable, c.modelPreempted,
c.capacityHolds, c.capacityGuarantee, c.capacityLimit,
c.engineInstall, c.leader,
} {
ch <- d
}
}
// Collect implements prometheus.Collector.
func (c *Collector) Collect(ch chan<- prometheus.Metric) {
now := time.Now()
c.collectQuotas(ch)
c.collectAssignments(ch)
loads := map[string]*inventory.Load{}
for _, n := range c.src.Nodes() {
fabric := ""
if len(n.Fabrics) > 0 {
fabric = n.Fabrics[0].Fabric
}
up := 0.0
if n.State == inventory.Ready {
up = 1
}
// The state is a label rather than a number, because a cordoned node
// and an unreachable one need different responses and a single gauge
// counting "not ready" would hide which it is.
ch <- prometheus.MustNewConstMetric(c.nodeUp, prometheus.GaugeValue, up,
n.ID, n.State.String(), fabric)
ch <- prometheus.MustNewConstMetric(c.nodeGPUsFree, prometheus.GaugeValue,
float64(len(c.src.FreeGPUs(n.ID))), n.ID)
ch <- prometheus.MustNewConstMetric(c.nodeMemory, prometheus.GaugeValue,
float64(n.MemoryTotalMB)*1024*1024, n.ID)
ch <- prometheus.MustNewConstMetric(c.nodeSeen, prometheus.GaugeValue,
now.Sub(n.LastSeen).Seconds(), n.ID)
// Nothing reported means nothing is known, so no sample at all. A zero
// here would read as a full disk and page someone about a node that
// was simply never asked.
if free, total := n.LocalDisk(); total > 0 {
ch <- prometheus.MustNewConstMetric(c.nodeDiskFree, prometheus.GaugeValue,
float64(free), n.ID)
ch <- prometheus.MustNewConstMetric(c.nodeDiskSize, prometheus.GaugeValue,
float64(total), n.ID)
}
if l := n.Load; l != nil && now.Sub(l.At) < loadFresh {
// Each only when measured: a VM has none of these, and a zero
// would read as a machine at 0 °C drawing nothing.
for _, v := range []struct {
d *prometheus.Desc
val float64
}{{c.nodeCPUTemp, l.CPUTempC}, {c.nodeCPUPower, l.CPUPowerW}, {c.nodeInletTemp, l.InletTempC}} {
if v.val > 0 {
ch <- prometheus.MustNewConstMetric(v.d, prometheus.GaugeValue, v.val, n.ID)
}
}
ch <- prometheus.MustNewConstMetric(c.nodeCPU, prometheus.GaugeValue, l.CPUPercent, n.ID)
if l.CPUCount > 0 {
ch <- prometheus.MustNewConstMetric(c.nodeCPUs, prometheus.GaugeValue, float64(l.CPUCount), n.ID)
}
for w, v := range map[string]float64{"1m": l.Load1, "5m": l.Load5, "15m": l.Load15} {
ch <- prometheus.MustNewConstMetric(c.nodeLoad, prometheus.GaugeValue, v, n.ID, w)
}
if l.MemUsedBytes > 0 || l.MemAvailBytes > 0 {
ch <- prometheus.MustNewConstMetric(c.nodeMemUsed, prometheus.GaugeValue, float64(l.MemUsedBytes), n.ID)
ch <- prometheus.MustNewConstMetric(c.nodeMemAvail, prometheus.GaugeValue, float64(l.MemAvailBytes), n.ID)
}
loads[n.ID] = l
}
for _, p := range n.IBPorts {
port := strconv.Itoa(p.Port)
active := 0.0
if p.Active() {
active = 1
}
ch <- prometheus.MustNewConstMetric(c.ibActive, prometheus.GaugeValue, active,
n.ID, p.HCA, port, p.LinkLayer, p.State, p.PhysState)
ch <- prometheus.MustNewConstMetric(c.ibRate, prometheus.GaugeValue, float64(p.RateGbps),
n.ID, p.HCA, port)
for name, v := range p.Counters {
ch <- prometheus.MustNewConstMetric(c.ibCounter, prometheus.CounterValue, float64(v),
n.ID, p.HCA, port, name)
}
}
fabricGPUs := 0
for _, g := range n.GPUs {
fb := g.Fabric
if fb == nil || strings.EqualFold(fb.State, "Not Supported") {
continue
}
fabricGPUs++
joined := 0.0
if fb.Domain() != "" {
joined = 1
}
ch <- prometheus.MustNewConstMetric(c.gpuNVLJoined, prometheus.GaugeValue, joined,
n.ID, strconv.Itoa(g.Index), fb.Domain(), fb.State)
}
if fabricGPUs > 0 {
up := 0.0
if n.IMEX.State == "active" && n.IMEX.Channels > 0 {
up = 1
}
ch <- prometheus.MustNewConstMetric(c.imexUp, prometheus.GaugeValue, up, n.ID)
}
byClass := map[string]int{}
for _, g := range n.GPUs {
class := g.Class()
byClass[class]++
labels := []string{n.ID, strconv.Itoa(g.Index), class}
// The sensors are the card's. A MIG instance shares its card's
// heat and power, but not its memory, and has no utilisation of
// its own that any driver reports: its memory is the instance's
// own reading, and its utilisation is left out rather than
// published as the card's or as zero.
s, fresh := sensorFor(n.Load, g.CardIndex(), now)
if g.IsMIG() {
ch <- prometheus.MustNewConstMetric(c.gpuMemoryTotal, prometheus.GaugeValue,
float64(g.MemoryTotalMB)*1024*1024, labels...)
ch <- prometheus.MustNewConstMetric(c.gpuMemoryUsed, prometheus.GaugeValue,
float64(g.MemoryUsedMB)*1024*1024, labels...)
} else if fresh && s.Busy() {
// What the card is doing now, sampled every heartbeat.
c.gpuBusy(ch, s, labels)
} else {
// An agent too old to sample it: what it read at
// registration, which is all there is.
ch <- prometheus.MustNewConstMetric(c.gpuMemoryTotal, prometheus.GaugeValue,
float64(g.MemoryTotalMB)*1024*1024, labels...)
ch <- prometheus.MustNewConstMetric(c.gpuMemoryUsed, prometheus.GaugeValue,
float64(g.MemoryUsedMB)*1024*1024, labels...)
if g.UtilizationPercent > 0 {
// Only when reported. A driver too old to give it would
// otherwise show every card at a flat zero, which reads as
// an idle fleet rather than a missing measurement.
ch <- prometheus.MustNewConstMetric(c.gpuUtil, prometheus.GaugeValue,
float64(g.UtilizationPercent), labels...)
}
}
// The sensors' fresh reading when there is one; the temperature
// read at registration otherwise, which is all an older agent sends.
if fresh {
c.gpuSensor(ch, s, labels)
} else if g.Health.TemperatureC > 0 {
ch <- prometheus.MustNewConstMetric(c.gpuTemp, prometheus.GaugeValue,
float64(g.Health.TemperatureC), labels...)
}
healthy := 0.0
if g.Health.OK() {
healthy = 1
}
ch <- prometheus.MustNewConstMetric(c.gpuHealthy, prometheus.GaugeValue, healthy, labels...)
ch <- prometheus.MustNewConstMetric(c.gpuNVLink, prometheus.GaugeValue,
float64(len(g.NVLinkPeers)), labels...)
ecc := float64(g.Health.ECCErrors)
if fresh && s.Busy() && s.ECCUncorrected >= 0 {
ecc = s.ECCUncorrected
}
ch <- prometheus.MustNewConstMetric(c.gpuECC, prometheus.GaugeValue, ecc, labels...)
}
for class, n2 := range byClass {
ch <- prometheus.MustNewConstMetric(c.nodeGPUs, prometheus.GaugeValue,
float64(n2), n.ID, class)
}
}
// The fabrics as the adapters find them: their subnet managers, and how
// many things disagree.
rep := fabrics.Analyze(c.src.Nodes(), nil, now)
for _, ph := range rep.Physical {
name := strings.Join(ph.Declared, ",")
if ph.SM != nil && ph.SM.GUID != "" {
ch <- prometheus.MustNewConstMetric(c.fabricMaster, prometheus.GaugeValue, 1, name, ph.Key, ph.SM.GUID)
}
byState := map[string]int{}
for _, sm := range ph.SMs {
byState[sm.State]++
}
for st, n := range byState {
ch <- prometheus.MustNewConstMetric(c.fabricSMs, prometheus.GaugeValue, float64(n), name, ph.Key, st)
}
}
levels := map[fabrics.Level]int{fabrics.Fail: 0, fabrics.Warn: 0, fabrics.Info: 0}
for _, p := range rep.Problems {
levels[p.Level]++
}
for l, n := range levels {
ch <- prometheus.MustNewConstMetric(c.fabricProblems, prometheus.GaugeValue, float64(n), string(l))
}
// Replicas by model and state, so a model stuck starting is visible as a
// shape on a graph rather than only in a log line nobody tails.
counts := map[[2]string]int{}
ready := map[string]int{}
for _, rep := range c.src.Replicas() {
// Each engine's share of its node, labelled with what it serves, so
// "which model is eating this machine" is one query.
for _, sh := range rep.Shards {
if l := loads[sh.NodeID]; l != nil {
if use, ok := l.Shards[sh.ID]; ok {
labels := []string{sh.NodeID, rep.Model, rep.ID, sh.ID}
ch <- prometheus.MustNewConstMetric(c.shardCPU, prometheus.GaugeValue, use.CPUCores, labels...)
ch <- prometheus.MustNewConstMetric(c.shardMemory, prometheus.GaugeValue, float64(use.RSSBytes), labels...)
}
}
}
counts[[2]string{rep.Model, rep.State.String()}]++
if rep.State == reconciler.Ready {
ready[rep.Model]++
}
if !rep.LastUsedAt.IsZero() {
// Only when known. A replica nothing has reported would otherwise
// look like the most idle thing in the cluster, and after a router
// restart that would be all of them at once.
ch <- prometheus.MustNewConstMetric(c.replicaIdle, prometheus.GaugeValue,
now.Sub(rep.LastUsedAt).Seconds(), rep.Model, rep.ID)
}
}
for k, v := range counts {
ch <- prometheus.MustNewConstMetric(c.replicaState, prometheus.GaugeValue,
float64(v), k[0], k[1])
}
hs, ok := c.src.(HealthSource)
if !ok {
for model, v := range ready {
ch <- prometheus.MustNewConstMetric(c.replicaReady, prometheus.GaugeValue,
float64(v), model)
}
return
}
for _, n := range c.src.Nodes() {
for _, p := range n.Provision {
ch <- prometheus.MustNewConstMetric(c.engineInstall, prometheus.GaugeValue, 1,
n.ID, p.Engine, p.Version, p.State)
}
}
lead := 0.0
if hs.IsLeader() {
lead = 1
}
ch <- prometheus.MustNewConstMetric(c.leader, prometheus.GaugeValue, lead)
for _, h := range hs.ModelHealth() {
// Ready is published at zero for what should be running — the one
// value ModelHasNothingServing exists to catch, and which, emitted
// only for replicas that were Ready, it never saw.
if h.Desired > 0 || ready[h.Model] > 0 {
ch <- prometheus.MustNewConstMetric(c.replicaReady, prometheus.GaugeValue,
float64(ready[h.Model]), h.Model)
}
ch <- prometheus.MustNewConstMetric(c.modelDesired, prometheus.GaugeValue, float64(h.Desired), h.Model)
ch <- prometheus.MustNewConstMetric(c.modelFailures, prometheus.GaugeValue, float64(h.Failures), h.Model)
ch <- prometheus.MustNewConstMetric(c.modelParked, prometheus.GaugeValue, b2f(h.Parked), h.Model)
ch <- prometheus.MustNewConstMetric(c.modelUnplaceable, prometheus.GaugeValue, b2f(h.Unplaceable), h.Model)
ch <- prometheus.MustNewConstMetric(c.modelPreempted, prometheus.CounterValue, float64(h.Preempted), h.Model, h.Class)
}
}
func b2f(b bool) float64 {
if b {
return 1
}
return 0
}
// OwnerSource says whose quota each model counts against, for labelling
// what its replicas hold. Asked for by type assertion.
type OwnerSource interface {
ModelOwners() map[string]string
}
// QuotaSource adds the tenancy tree's capacity quotas. Asked for by type
// assertion, like HealthSource.
type QuotaSource interface {
QuotaUse() []reconciler.QuotaUse
}
func (c *Collector) collectQuotas(ch chan<- prometheus.Metric) {
qs, ok := c.src.(QuotaSource)
if !ok {
return
}
for _, q := range qs.QuotaUse() {
for _, r := range []struct {
name string
holds int
gua, lim *int
}{
{"gpus", q.Holds.GPUs, q.Guarantee.GPUs, q.Limit.GPUs},
{"cpu_cores", q.Holds.CPUCores, q.Guarantee.CPUCores, q.Limit.CPUCores},
{"memory_gb", q.Holds.MemoryGB, q.Guarantee.MemoryGB, q.Limit.MemoryGB},
} {
if r.gua == nil && r.lim == nil {
continue
}
ch <- prometheus.MustNewConstMetric(c.capacityHolds, prometheus.GaugeValue, float64(r.holds), q.Scope, r.name)
if r.gua != nil {
ch <- prometheus.MustNewConstMetric(c.capacityGuarantee, prometheus.GaugeValue, float64(*r.gua), q.Scope, r.name)
}
if r.lim != nil {
ch <- prometheus.MustNewConstMetric(c.capacityLimit, prometheus.GaugeValue, float64(*r.lim), q.Scope, r.name)
}
}
}
}
// sensorFor is a GPU's fresh sensor reading, if the node sent one.
func sensorFor(l *inventory.Load, index int, now time.Time) (inventory.GPUSensor, bool) {
if l == nil || now.Sub(l.At) >= loadFresh {
return inventory.GPUSensor{}, false
}
for _, g := range l.GPUs {
if g.Index == index {
return g, true
}
}
return inventory.GPUSensor{}, false
}
// gpuBusy is how busy a card is, from a sample that carries it.
func (c *Collector) gpuBusy(ch chan<- prometheus.Metric, s inventory.GPUSensor, labels []string) {
ch <- prometheus.MustNewConstMetric(c.gpuMemoryTotal, prometheus.GaugeValue, s.MemoryTotalMB*1024*1024, labels...)
ch <- prometheus.MustNewConstMetric(c.gpuMemoryUsed, prometheus.GaugeValue, s.MemoryUsedMB*1024*1024, labels...)
// Zero is a real reading here — an idle card — and only -1, the driver
// not saying, leaves the series out.
if s.UtilPercent >= 0 {
ch <- prometheus.MustNewConstMetric(c.gpuUtil, prometheus.GaugeValue, s.UtilPercent, labels...)
}
if s.MemUtilPercent >= 0 {
ch <- prometheus.MustNewConstMetric(c.gpuMemUtil, prometheus.GaugeValue, s.MemUtilPercent, labels...)
}
if s.SMClockMHz > 0 {
ch <- prometheus.MustNewConstMetric(c.gpuSMClock, prometheus.GaugeValue, s.SMClockMHz, labels...)
}
// The card's profile, here rather than with the sensors because it is
// the whole card's: a MIG instance must not be published as having it.
if p := s.Profile; p != nil {
for _, v := range []struct {
d *prometheus.Desc
val float64
}{{c.gpuSMActive, p.SMActive}, {c.gpuSMOccupancy, p.SMOccupancy}, {c.gpuTensor, p.TensorActive}, {c.gpuDRAMActive, p.DRAMActive}} {
// Zero is an idle chip; only -1, not reported, is left out.
if v.val >= 0 {
ch <- prometheus.MustNewConstMetric(v.d, prometheus.GaugeValue, v.val, labels...)
}
}
}
}
func (c *Collector) gpuSensor(ch chan<- prometheus.Metric, s inventory.GPUSensor, labels []string) {
for _, v := range []struct {
d *prometheus.Desc
val float64
}{{c.gpuTemp, s.TempC}, {c.gpuMemTemp, s.MemoryTempC}, {c.gpuPower, s.PowerW}, {c.gpuPowerLimit, s.PowerLimitW}} {
if v.val > 0 {
ch <- prometheus.MustNewConstMetric(v.d, prometheus.GaugeValue, v.val, labels...)
}
}
for _, reason := range s.Throttle {
ch <- prometheus.MustNewConstMetric(c.gpuThrottled, prometheus.GaugeValue, 1, append(labels, reason)...)
}
if w := s.Wear; w != nil {
c.gpuWear(ch, w, labels)
}
}
// gpuWear is what wears a card out. A count the card does not keep (-1) is
// left out, not published as zero.
func (c *Collector) gpuWear(ch chan<- prometheus.Metric, w *inventory.GPUWear, labels []string) {
gauge := func(d *prometheus.Desc, v float64, extra ...string) {
ch <- prometheus.MustNewConstMetric(d, prometheus.GaugeValue, v, append(append([]string{}, labels...), extra...)...)
}
flag := func(b bool) float64 {
if b {
return 1
}
return 0
}
if w.PCIeReplays >= 0 {
gauge(c.gpuPCIeReplay, float64(w.PCIeReplays))
}
if w.RetiredSBE >= 0 || w.RetiredDBE >= 0 {
gauge(c.gpuRetired, float64(max(w.RetiredSBE, 0)), "sbe")
gauge(c.gpuRetired, float64(max(w.RetiredDBE, 0)), "dbe")
gauge(c.gpuRetirePend, flag(w.RetirePending))
}
if w.RemappedCorrectable >= 0 || w.RemappedUncorrectable >= 0 {
gauge(c.gpuRemapped, float64(max(w.RemappedCorrectable, 0)), "correctable")
gauge(c.gpuRemapped, float64(max(w.RemappedUncorrectable, 0)), "uncorrectable")
gauge(c.gpuRemapPend, flag(w.RemapPending))
gauge(c.gpuRemapFail, flag(w.RemapFailure))
}
gauge(c.gpuNVLinkErr, float64(w.NVLinkCRC), "crc")
gauge(c.gpuNVLinkErr, float64(w.NVLinkReplay), "replay")
gauge(c.gpuNVLinkErr, float64(w.NVLinkRecovery), "recovery")
gauge(c.gpuXID, float64(w.XIDs))
if w.XIDs > 0 {
gauge(c.gpuLastXID, float64(w.LastXID))
}
}
// collectAssignments says which replica holds each GPU.
func (c *Collector) collectAssignments(ch chan<- prometheus.Metric) {
var owners map[string]string
if o, ok := c.src.(OwnerSource); ok {
owners = o.ModelOwners()
}
for _, r := range c.src.Replicas() {
if !r.State.Counts() {
continue
}
for _, sh := range r.Shards {
for _, g := range sh.GPUIndices {
ch <- prometheus.MustNewConstMetric(c.gpuAssigned, prometheus.GaugeValue, 1,