A fabric was what agent.yaml called it. With several independent
InfiniBand fabrics at a site, two given one name would have had a
replica spread across both, starting and then hanging on its first
collective. Each active InfiniBand port now reports the master subnet
manager it sees (sminfo, asked once a minute), which every port on one
fabric shares and ports on separate fabrics cannot; a RoCE port reports
the IP network of its RoCE v2 address. Ports also carry their node and
port GUIDs.
Placement divides a declared fabric by that physical identity and forms
a replica on one part only; a node whose adapters for one name are on
two fabrics is refused, and a node that cannot say is kept apart from
those that can. /api/v1/fabrics and the cluster page list each physical
fabric with its subnet manager, and say when one name covers two
fabrics, two names one fabric, an adapter is up but undeclared, or a
node cannot be checked. doctor reports each port's subnet manager, and
an agent on a node with adapters installs infiniband-diags when sminfo
is missing.
Co-Authored-By: Claude Opus 5.5 (1M context) <noreply@anthropic.com>