Not persisting replica state left one hole: restarting the control plane made it
forget every replica while the engines kept running. They held GPUs the
inventory believed were free, so the next placement failed to allocate, with an
error naming the new process rather than the old one.
The fix belongs on the agent, not in a database. A row can say "running" about a
process that died; the fleet cannot.
- the supervisor writes the full shard spec, not just a pid and command line. A
pid identifies a process; the spec is what lets it be described back to the
control plane and matched to a replica.
- Adopt takes over an engine a previous agent left running. It is not this
process's child, so it cannot be waited on: it is watched by polling and
stopped by signalling its group directly. Its earlier output is gone and the
log says so rather than presenting emptiness as silence.
- every Register reports what the agent is running, not only the first, because
a reconnect may be a control plane restart and has to recover the same way.
- the reconciler rebuilds replicas from those reports and reclaims their GPUs.
Anything whose model or profile left the catalog is stopped; nothing will
route to it and it is holding cards.
- an engine the agent cannot identify is killed. A process holding GPUs that
nothing can describe is worse than no process, because placement hands those
GPUs out again.
Stop was also wrong for adopted shards: it checked for an exec.Cmd, which they
do not have, and reported them stopped without killing anything.
TestAgentReconnects had been passing for no reason. httptest's
CloseClientConnections does nothing to an h2c stream — prior-knowledge h2c
hijacks the connection and httptest stops tracking hijacked ones — so the agent
never reconnected, and the assertion on the connection map passed on a stale
entry. Tests now sever connections through their own listener and count opened
streams.
Plan §11 also records what multi-node still needs, since placement landing early
makes it look further along than it is: workers never become Ready because the
agent health-checks every shard while only rank 0 serves HTTP; RayCommand is
written and tested but never called; and startup is fire-and-forget.
Co-Authored-By: Claude Opus 5 (1M context) <noreply@anthropic.com>
Everything here works without GPUs and is covered by tests. The control plane
connection is not built yet, so llmgw agent itself is still a stub and the phase
exit criterion is not met.
- discovery: IB from /sys/class/infiniband, parsing the formats sysfs actually
uses and telling native InfiniBand from RoCE; GPUs via nvidia-smi, the
cgo-free path, with health flags for uncorrected ECC and memory already held
by another process. A node without IB is not an error, it is a single-node
island.
- engines: vLLM and SGLang command and environment construction, kept free of
process handling so it stays testable. The NCCL environment is the part the
plan marks critical: NCCL_IB_HCA lists only the chosen fabric's adapters,
because leaving it open lets NCCL pick an adapter on a fabric where the peer
is unreachable, and the job then hangs instead of failing.
- validation before launch: no mixed GPU types in a tensor-parallel group, the
node/GPU/TP arithmetic has to add up, and fp8 is refused below compute
capability 8.9 rather than silently falling back to a slower path.
- supervisor: process groups, because engines fork workers that hold GPU memory
and outlive a signal sent only to the leader; a bounded log tail, since engine
output is the only diagnosis when loading fails; Starting separate from
Loading, because a 70B model legitimately takes minutes; and orphan adoption
through pid files fingerprinted with the command line, since pids get reused
and adopting an unrelated process is worse than leaking the original.
- readiness is two questions: /health says the process is up, /v1/models says
the weights loaded. Routing on /health alone sends traffic into a loading model.
- llmgw agent inventory reports what the scheduler would see on a node.
One plan correction: GPU class sizes come from the driver in GiB, which does not
always match the marketing name. An L40S is sold as 48GB and reports 44.99 GiB,
so its class is l40s-45g, not l40s-48g. Consistency matters more than matching
the box, because that number decides whether a model fits. Plan §2 and §5.1
updated.
Co-Authored-By: Claude Opus 5 (1M context) <noreply@anthropic.com>