Ilker ManapandClaude Opus 5.5 45e3f52da3 Launch multi-node vLLM its own way by default, not through Ray
An empty launch_mode meant ray: a Ray head and joins on every node, a
dependency to install, and a path never checked against a real cluster.
It now means mp - every node runs vllm serve with its rank and the
leader's address, the workers headless - which is how vLLM documents a
multi-node launch today and needs nothing but vLLM. ray is still there
for a vLLM too old for mp's flags. The example agent configuration,
doctor and the reference say so.

Co-Authored-By: Claude Opus 5.5 (1M context) <noreply@anthropic.com>
2026-09-29 09:13:59 +02:00
Ilker ManapandClaude Opus 5.5 20479a2d5f Find multi-node NVLink domains, place across them, and show them as racks
A GB200 NVL72 rack or an NVLink Switch system is a scale-up island: its
GPUs reach each other over NVLink whatever node they are in. Each GPU
now reports its fabric from nvidia-smi -q - state, status, ClusterUUID,
CliqueId, bandwidth - at registration and once a minute after, since a
fabric manager restarting drops every card out at once; and each node
reports nvidia-imex and its channels, without which the domain's GPUs
cannot share memory across nodes. A single machine's NVSwitch, which
reports a cluster of zeros, is no domain.

A replica spanning nodes is placed inside one domain first, on nodes
whose every card is joined and whose IMEX is up, and its shards are
told NCCL_MNNVL_ENABLE=1; InfiniBand is the fallback.

/admin/nvlink draws each domain as a rack - the NVLink Switch band on
top, light running down a backplane, trays of GPU chips that glow when
joined, pulse red when not, turn amber on degraded bandwidth - and
lists what keeps a tray out. A node's page shows its GPU-by-GPU NVLink
matrix, each card's NUMA node and nearest adapter, and its domain and
IMEX. doctor checks joining, bandwidth, IMEX and its channel; metrics
llmgw_gpu_nvlink_joined and llmgw_imex_up; /api/v1/nvlink.

Co-Authored-By: Claude Opus 5.5 (1M context) <noreply@anthropic.com>
2026-09-29 09:07:59 +02:00
Ilker ManapandClaude Opus 5.5 23648fa19a Watch each fabric's subnet managers, and keep a fabric one through a failover
A fabric's identity was its master subnet manager, which changes on a
failover: for the minute its ports took to agree, one fabric read as
two, and a name covering it as two separate fabrics. Each agent now
also lists every subnet manager on a fabric (saquery SMIR, through one
port per master, once a minute); managers listed together are one
fabric, named by the lowest GUID among them, so the identity survives
the master changing.

The same list says what a fabric can survive. The cluster page's new
subnet manager table, /api/v1/fabrics, doctor and metrics
(llmgw_fabric_master_sm, llmgw_fabric_subnet_managers,
llmgw_fabric_problems) show each fabric's master, priority and
standbys, and say when a fabric has no standby, its ports disagree on
the master, ports are up with no subnet manager (INIT), or the master
changed in the last hour. Every change of master a port reports is
kept, and a fabric's last day of them is listed.

Co-Authored-By: Claude Opus 5.5 (1M context) <noreply@anthropic.com>
2026-09-29 07:47:03 +02:00
Ilker ManapandClaude Opus 5.5 77fe801892 Tell independent fabrics apart by their subnet manager, not their name
A fabric was what agent.yaml called it. With several independent
InfiniBand fabrics at a site, two given one name would have had a
replica spread across both, starting and then hanging on its first
collective. Each active InfiniBand port now reports the master subnet
manager it sees (sminfo, asked once a minute), which every port on one
fabric shares and ports on separate fabrics cannot; a RoCE port reports
the IP network of its RoCE v2 address. Ports also carry their node and
port GUIDs.

Placement divides a declared fabric by that physical identity and forms
a replica on one part only; a node whose adapters for one name are on
two fabrics is refused, and a node that cannot say is kept apart from
those that can. /api/v1/fabrics and the cluster page list each physical
fabric with its subnet manager, and say when one name covers two
fabrics, two names one fabric, an adapter is up but undeclared, or a
node cannot be checked. doctor reports each port's subnet manager, and
an agent on a node with adapters installs infiniband-diags when sminfo
is missing.

Co-Authored-By: Claude Opus 5.5 (1M context) <noreply@anthropic.com>
2026-09-29 07:29:16 +02:00
Ilker ManapandClaude Opus 5.5 1b1ca67e35 Add llmgw doctor: what a node's GPUs, NVLink and fabric need, checked
For machines nobody here can log into. It reads the GPUs and their
nvidia-smi topology, NVSwitch and the fabric manager, every InfiniBand
and RoCE port with its counters and RoCE v2 GID, the RDMA and
GPUDirect kernel modules, the agent's declared fabrics against the
adapters, the management interface NCCL will bootstrap over, the
agent unit's memlock limit and the engines installed - and says what
is wrong and how to fix it, most serious first, with the NCCL
environment a shard on each fabric would be given. --json writes every
fact it concluded from, to send back. It exits non-zero when something
fails.

Co-Authored-By: Claude Opus 5.5 (1M context) <noreply@anthropic.com>
2026-09-29 03:51:09 +02:00