Read nodes' heat and power: GPUs, CPUs, board inlet, RAPL
Every agent samples, at most every ten seconds: nvidia-smi's temperature, HBM temperature, power draw, enforced limit and throttle reasons per GPU; hwmon's CPU package and board inlet temperatures; and CPU package power from RAPL's energy counters. Sent with heartbeats, published as metrics and shown on the node page; unmeasured sensors are absent, never zero. Observe-only, step 0 of docs/facility-aware-placement.md, which now describes the agent source and what these readings can and cannot say. Co-Authored-By: Claude Opus 5.5 (1M context) <noreply@anthropic.com>
This commit is contained in:
1 parent
8724dc027a
commit
cd10e086c8
15 files changed
+996
-172
No files matched your search
@@ -249,6 +249,11 @@ type LoadView struct {
|
||||
// MemPercent is used over used plus available.
|
||||
MemPercent float64 `json:"memory_percent"`
|
||||
AgeSec int64 `json:"age_seconds"`
|
||||
// What the node's sensors say; zero is not measured.
|
||||
CPUTempC float64 `json:"cpu_temp_c,omitempty"`
|
||||
CPUPowerW float64 `json:"cpu_power_w,omitempty"`
|
||||
InletTempC float64 `json:"inlet_temp_c,omitempty"`
|
||||
GPUs []inventory.GPUSensor `json:"gpu_sensors,omitempty"`
|
||||
}
|
||||
|
||||
// loadFresh is how old a measurement may be and still be shown as current.
|
||||
@@ -262,7 +267,8 @@ func loadView(l *inventory.Load, now time.Time) *LoadView {
|
||||
CPUPercent: l.CPUPercent, CPUs: l.CPUCount,
|
||||
Load1: l.Load1, Load5: l.Load5, Load15: l.Load15,
|
||||
MemUsed: l.MemUsedBytes, MemTotal: l.MemUsedBytes + l.MemAvailBytes,
|
||||
AgeSec: int64(now.Sub(l.At).Seconds()),
|
||||
AgeSec: int64(now.Sub(l.At).Seconds()),
|
||||
CPUTempC: l.CPUTempC, CPUPowerW: l.CPUPowerW, InletTempC: l.InletTempC, GPUs: l.GPUs,
|
||||
}
|
||||
if v.MemTotal > 0 {
|
||||
v.MemPercent = float64(v.MemUsed) * 100 / float64(v.MemTotal)
|
||||
|
||||