Merge C24 facility-aware placement
Co-Authored-By: Claude Opus 5.5 (1M context) <noreply@anthropic.com>
This commit is contained in:
commit
3ec90ded72
42 files changed
+3510
-63
No files matched your search
+23
-2
@@ -862,8 +862,8 @@ llmgw ctl nodes
|
||||
```
|
||||
|
||||
```
|
||||
NODE STATE GPUS MEM CLASSES FABRICS REPLICAS LAST SEEN
|
||||
llmgw-node01 ready 8/8 free 503G h100-80g ib-a 0 2s
|
||||
NODE STATE LOCATION GPUS MEM CLASSES FABRICS REPLICAS LAST SEEN
|
||||
llmgw-node01 ready - 8/8 free 503G h100-80g ib-a 0 2s
|
||||
```
|
||||
|
||||
If it does not appear, the control plane's log says why. A certificate whose
|
||||
@@ -875,6 +875,27 @@ Repeat for each node. Nodes in the same fabric must be given the same `--fabric`
|
||||
name; nodes with no InfiniBand take no `--fabric` at all and are each their own
|
||||
island, which is fine for single-node models.
|
||||
|
||||
### Saying where the node is
|
||||
|
||||
On more than one rack, tell llmgw which rack, and which PDUs, each node is in.
|
||||
Placement then keeps a model's replicas in different racks and on different
|
||||
PDUs, places nothing in a rack held for maintenance, and keeps each rack under
|
||||
a power cap if you give it one:
|
||||
|
||||
```
|
||||
llmgw ctl label llmgw-node01 llmgw.io/rack=r12-07 llmgw.io/pdu=r12-07-a,r12-07-b
|
||||
llmgw ctl label llmgw-node01 llmgw.io/row=12 llmgw.io/room=hall-b llmgw.io/site=sto1
|
||||
```
|
||||
|
||||
Labels set this way are kept by the control plane and win over the node's
|
||||
`agent.yaml`, where the same keys can go under `labels:` instead; a node need
|
||||
not have joined yet. `llmgw ctl nodes` shows the LOCATION, `--domain
|
||||
rack:r12-07` lists one rack, and `llmgw ctl facility` lists every rack, row and
|
||||
PDU with what it draws. In the console it is the node's menu, **Location…**.
|
||||
A node with no location is placed as before, as a rack of its own.
|
||||
See [facility-aware-placement.md](facility-aware-placement.md) for power caps
|
||||
and holds.
|
||||
|
||||
## 6. Setting the node's CPU model, if it is a VM
|
||||
|
||||
Proxmox defaults a VM to `kvm64`, which hides AVX, AVX2, FMA and even SSE4.2
|
||||
|
||||
Reference in new issue
Block a user