Find multi-node NVLink domains, place across them, and show them as racks

A GB200 NVL72 rack or an NVLink Switch system is a scale-up island: its
GPUs reach each other over NVLink whatever node they are in. Each GPU
now reports its fabric from nvidia-smi -q - state, status, ClusterUUID,
CliqueId, bandwidth - at registration and once a minute after, since a
fabric manager restarting drops every card out at once; and each node
reports nvidia-imex and its channels, without which the domain's GPUs
cannot share memory across nodes. A single machine's NVSwitch, which
reports a cluster of zeros, is no domain.

A replica spanning nodes is placed inside one domain first, on nodes
whose every card is joined and whose IMEX is up, and its shards are
told NCCL_MNNVL_ENABLE=1; InfiniBand is the fallback.

/admin/nvlink draws each domain as a rack - the NVLink Switch band on
top, light running down a backplane, trays of GPU chips that glow when
joined, pulse red when not, turn amber on degraded bandwidth - and
lists what keeps a tray out. A node's page shows its GPU-by-GPU NVLink
matrix, each card's NUMA node and nearest adapter, and its domain and
IMEX. doctor checks joining, bandwidth, IMEX and its channel; metrics
llmgw_gpu_nvlink_joined and llmgw_imex_up; /api/v1/nvlink.

Co-Authored-By: Claude Opus 5.5 (1M context) <noreply@anthropic.com>
This commit is contained in:
Ilker ManapandClaude Opus 5.5 committed 2026-09-29 09:07:59 +02:00
1 parent 5bbc619a31
commit 20479a2d5f
31 files changed
+1535 -131

No files matched your search

+7
View File
@@ -165,6 +165,13 @@ A replica spanning nodes is only ever formed on one of those. Fully free counts
unused nodes, which is what decides whether such a replica can land.</p>
{{end}}
{{with .NVLink}}
<h2>NVLink domains</h2>
<p>{{len .Domains}} multi-node domain{{if ne (len .Domains) 1}}s{{end}}{{range .Domains}} · <code>{{shortDomain .Key}}</code> {{.Usable}}/{{len .Members}} trays usable{{end}}
{{if .Problems}} · <span class="bad">{{len .Problems}} problem{{if ne (len .Problems) 1}}s{{end}}</span>{{end}}
· <a href="{{if $.OnAdminListener}}/nvlink{{else}}/admin/nvlink{{end}}">see the racks →</a></p>
{{end}}
{{with .Fleet}}
<h2>What the cluster is doing <span class="opt">last {{.Window}}</span></h2>
{{if .Err}}